327 related articles for article (PubMed ID: 9310812)
1. Comparison between cardiac output measured by thermodilution technique and calculated by O2 and modified CO2 Fick methods using a new metabolic monitor.
Brandi LS; Bertolini R; Pieri M; Giunta F; Calafà M
Intensive Care Med; 1997 Aug; 23(8):908-15. PubMed ID: 9310812
[TBL] [Abstract][Full Text] [Related]
2. Cardiac output from carbon dioxide production and arterial and venous oximetry.
Mahutte CK; Jaffe MB; Sassoon CS; Wong DH
Crit Care Med; 1991 Oct; 19(10):1270-7. PubMed ID: 1914484
[TBL] [Abstract][Full Text] [Related]
3. Oxygen Fick and modified carbon dioxide Fick cardiac outputs.
Mahutte CK; Jaffe MB; Chen PA; Sasse SA; Wong DH; Sassoon CS
Crit Care Med; 1994 Jan; 22(1):86-95. PubMed ID: 8124981
[TBL] [Abstract][Full Text] [Related]
4. Relationship of thermodilution cardiac output to metabolic measurements and mixed venous oxygen saturation.
Mahutte CK; Jaffe MB; Sasse SA; Chen PA; Berry RB; Sassoon CS
Chest; 1993 Oct; 104(4):1236-42. PubMed ID: 8404199
[TBL] [Abstract][Full Text] [Related]
5. [Comparison of 2 modified Fick methods and thermodilution for determining the cardiac output in patients with mechanical ventilation].
Corbanese U; Possamai C
Minerva Anestesiol; 1995 May; 61(5):191-9. PubMed ID: 7478050
[TBL] [Abstract][Full Text] [Related]
6. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.
Chang AC; Kulik TJ; Hickey PR; Wessel DL
Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302
[TBL] [Abstract][Full Text] [Related]
7. Effect of measurement errors on cardiac output calculated with O2 and modified CO2 Fick methods.
Mahutte CK; Jaffe MB
J Clin Monit; 1995 Mar; 11(2):99-108. PubMed ID: 7760094
[TBL] [Abstract][Full Text] [Related]
8. Continuous thermodilution cardiac output: agreement with Fick and bolus thermodilution methods.
Thrush D; Downs JB; Smith RA
J Cardiothorac Vasc Anesth; 1995 Aug; 9(4):399-404. PubMed ID: 7579109
[TBL] [Abstract][Full Text] [Related]
9. Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method.
Wippermann CF; Huth RG; Schmidt FX; Thul J; Betancor M; Schranz D
Intensive Care Med; 1996 May; 22(5):467-71. PubMed ID: 8796404
[TBL] [Abstract][Full Text] [Related]
10. Continual trending of Fick variables in the critically ill patient.
Quinn TJ; Weissman C; Kemper M
Chest; 1991 Mar; 99(3):703-7. PubMed ID: 1899824
[TBL] [Abstract][Full Text] [Related]
11. Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation.
Lynch J; Kaemmerer H
Intensive Care Med; 1990; 16(4):248-51. PubMed ID: 2358558
[TBL] [Abstract][Full Text] [Related]
12. Continuous measurement of cardiac output by the Fick principle: clinical validation in intensive care.
Keinänen O; Takala J; Kari A
Crit Care Med; 1992 Mar; 20(3):360-5. PubMed ID: 1541096
[TBL] [Abstract][Full Text] [Related]
13. Feasibility of continuous oxygen delivery and cardiac output measurement by application of the Fick principle.
Feustel PJ; Perkins RJ; Oppenlander JE; Stratton HH; Cohen IL
Am J Respir Crit Care Med; 1994 Mar; 149(3 Pt 1):751-8. PubMed ID: 8118646
[TBL] [Abstract][Full Text] [Related]
14. Effects of ventilator resetting on indirect calorimetry measurement in the critically ill surgical patient.
Brandi LS; Bertolini R; Santini L; Cavani S
Crit Care Med; 1999 Mar; 27(3):531-9. PubMed ID: 10199532
[TBL] [Abstract][Full Text] [Related]
15. Comparison of transesophageal echocardiographic, fick, and thermodilution cardiac output in critically ill patients.
Axler O; Tousignant C; Thompson CR; Dall'ava-Santucci J; Phang PT; Russell JA; Walley KR
J Crit Care; 1996 Sep; 11(3):109-16. PubMed ID: 8891961
[TBL] [Abstract][Full Text] [Related]
16. Energy expenditure and gas exchange measurements in postoperative patients: thermodilution versus indirect calorimetry.
Brandi LS; Grana M; Mazzanti T; Giunta F; Natali A; Ferrannini E
Crit Care Med; 1992 Sep; 20(9):1273-83. PubMed ID: 1521442
[TBL] [Abstract][Full Text] [Related]
17. Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants.
Tibby SM; Hatherill M; Marsh MJ; Morrison G; Anderson D; Murdoch IA
Intensive Care Med; 1997 Sep; 23(9):987-91. PubMed ID: 9347372
[TBL] [Abstract][Full Text] [Related]
18. Lack of agreement between thermodilution and fick cardiac output in critically ill patients.
Dhingra VK; Fenwick JC; Walley KR; Chittock DR; Ronco JJ
Chest; 2002 Sep; 122(3):990-7. PubMed ID: 12226045
[TBL] [Abstract][Full Text] [Related]
19. Calculated and measured oxygen consumption in mechanically ventilated surgical patients in the early post-operative period.
Brandi LS; Bertolini R; Santini L
Eur J Anaesthesiol; 1999 Jan; 16(1):53-61. PubMed ID: 10084102
[TBL] [Abstract][Full Text] [Related]
20. Comparison between measured and fick-derived values of hemodynamic and oxymetric variables in patients with acute myocardial infarction.
Pomés Iparraguirre H; Giniger R; Garber VA; Quiroga E; Jorge MA
Am J Med; 1988 Sep; 85(3):349-52. PubMed ID: 3414730
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]