These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 9321441)

  • 61. Does the presence of a funnel increase the risk of adverse perinatal outcome in a patient with a short cervix?
    Rust OA; Atlas RO; Kimmel S; Roberts WE; Hess LW
    Am J Obstet Gynecol; 2005 Apr; 192(4):1060-6. PubMed ID: 15846180
    [TBL] [Abstract][Full Text] [Related]  

  • 62. [Study of the cervix of normal pregnancy and threatened preterm delivery using transvaginal sonography].
    Shi CY; Zhang YY; Jin YZ; Dong Y
    Zhonghua Fu Chan Ke Za Zhi; 2003 May; 38(5):264-6. PubMed ID: 12895306
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Role of ultrasound in screening patients at risk for preterm delivery.
    Doyle NM; Monga M
    Obstet Gynecol Clin North Am; 2004 Mar; 31(1):125-39. PubMed ID: 15062450
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Analysis of cervical dynamics by ultrasound imaging.
    Pugatsch R; Elad D; Jaffa AJ; Eytan O
    Ann N Y Acad Sci; 2007 Apr; 1101():203-14. PubMed ID: 17303836
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Ultrasonographic examination of the uterine cervix is better than cervical digital examination as a predictor of the likelihood of premature delivery in patients with preterm labor and intact membranes.
    Gomez R; Galasso M; Romero R; Mazor M; Sorokin Y; Gonçalves L; Treadwell M
    Am J Obstet Gynecol; 1994 Oct; 171(4):956-64. PubMed ID: 7943109
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Don't be short-sighted: cervical incompetence in a pregnant patient with acute appendicitis.
    Negrete LM; Spalluto LB
    Clin Imaging; 2018; 51():35-37. PubMed ID: 29414522
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Evaluation of the upper uterine cervix by the location of the vesicocervical fold of the urinary bladder to rule out cervical shortening during pregnancy with and without premature contractions.
    Shalev J; Meizner I; Orvieto R; Mashiach R; Vardimon D; Hod M; Ben-Rafael Z
    Ultrasound Obstet Gynecol; 1999 Jun; 13(6):401-6. PubMed ID: 10423803
    [TBL] [Abstract][Full Text] [Related]  

  • 68. [Cervix incompetence].
    Broso RP; Garrone C
    Minerva Ginecol; 1997; 49(7-8):329-33. PubMed ID: 9380295
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Can a "snapshot" sagittal view of the cervix by transvaginal ultrasonography predict active preterm labor?
    Timor-Tritsch IE; Boozarjomehri F; Masakowski Y; Monteagudo A; Chao CR
    Am J Obstet Gynecol; 1996 Mar; 174(3):990-5. PubMed ID: 8633681
    [TBL] [Abstract][Full Text] [Related]  

  • 70. [Transvaginal ultrasound of the cervix in the estimation of severity of premature labour].
    Boudhraa K; Rahouej H; Gara MF
    Tunis Med; 2008 Aug; 86(8):745-8. PubMed ID: 19472759
    [TBL] [Abstract][Full Text] [Related]  

  • 71. [Vaginal sonographic assessment of placenta praevia].
    Krone S; Wisser J
    Gynakol Rundsch; 1991; 31 Suppl 2():155-7. PubMed ID: 1790909
    [No Abstract]   [Full Text] [Related]  

  • 72. [Cervical incompetence in multifetal gestation: diagnosis and prophylaxis].
    Strauss A; Müller-Egloff S; Heer IM; Dannecker C; Hepp H
    Gynakol Geburtshilfliche Rundsch; 2003 Apr; 43(2):91-7. PubMed ID: 12649581
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Cervical surveillance as an alternative to elective cervical cerclage for pregnancy management of suspected cervical incompetence.
    Higgins SP; Kornman LH; Bell RJ; Brennecke SP
    Aust N Z J Obstet Gynaecol; 2004 Jun; 44(3):228-32. PubMed ID: 15191447
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Ultrasound assessment of cervical length in threatened preterm labor.
    Tsoi E; Akmal S; Rane S; Otigbah C; Nicolaides KH
    Ultrasound Obstet Gynecol; 2003 Jun; 21(6):552-5. PubMed ID: 12808671
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Sonographic measurement of cervical length in twin pregnancies in threatened preterm labor.
    Fuchs I; Tsoi E; Henrich W; Dudenhausen JW; Nicolaides KH
    Ultrasound Obstet Gynecol; 2004 Jan; 23(1):42-5. PubMed ID: 14970998
    [TBL] [Abstract][Full Text] [Related]  

  • 76. [Transvaginal sonography in prediction of preterm delivery in patients presenting with signs and symptoms of preterm labor].
    Hincz P; Wilczyński J; Kozarzewski M; Szaflik K
    Ginekol Pol; 2001 Oct; 72(10):778-82. PubMed ID: 11848013
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Effects of cervical cerclage on cervical length and the impact of changes in cervical length on pregnancy prognosis.
    Herbst SSR; Peixoto AB; Araujo Júnior E; Moron AF; Mattar R
    Ceska Gynekol; 2018; 83(5):341-347. PubMed ID: 30848137
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Translabial ultrasonography and placenta previa: does measurement of the os-placenta distance predict outcome?
    Dawson WB; Dumas MD; Romano WM; Gagnon R; Gratton RJ; Mowbray RD
    J Ultrasound Med; 1996 Jun; 15(6):441-6. PubMed ID: 8738988
    [TBL] [Abstract][Full Text] [Related]  

  • 79. The natural history of a positive response to transfundal pressure in women at risk for cervical incompetence.
    Guzman ER; Vintzileos AM; McLean DA; Martins ME; Benito CW; Hanley ML
    Am J Obstet Gynecol; 1997 Mar; 176(3):634-8. PubMed ID: 9077619
    [TBL] [Abstract][Full Text] [Related]  

  • 80. [Usefulness of ultrasonography of the cervical canal in the screening of pregnant women at risk of premature labor].
    Felicetti M; Di Domenico A; Salzano P; Borrelli P; Borrelli M; Laboccetta A; Di Monaco A; Borrelli AL
    Minerva Ginecol; 2001 Feb; 53(1 Suppl 1):82-5. PubMed ID: 11526729
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.