These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 9324326)
21. Two-pulse nutation echoes generated by gradients of the radiofrequency amplitude and of the main magnetic field. Ardelean I; Scharfenecker A; Kimmich R J Magn Reson; 2000 May; 144(1):45-52. PubMed ID: 10783272 [TBL] [Abstract][Full Text] [Related]
22. Tailoring the optimal control cost function to a desired output: application to minimizing phase errors in short broadband excitation pulses. Skinner TE; Reiss TO; Luy B; Khaneja N; Glaser SJ J Magn Reson; 2005 Jan; 172(1):17-23. PubMed ID: 15589403 [TBL] [Abstract][Full Text] [Related]
23. Multiband RF pulses with improved performance via convex optimization. Shang H; Larson PEZ; Kerr A; Reed G; Sukumar S; Elkhaled A; Gordon JW; Ohliger MA; Pauly JM; Lustig M; Vigneron DB J Magn Reson; 2016 Jan; 262():81-90. PubMed ID: 26754063 [TBL] [Abstract][Full Text] [Related]
24. ZTE imaging with enhanced flip angle using modulated excitation. Schieban K; Weiger M; Hennel F; Boss A; Pruessmann KP Magn Reson Med; 2015 Sep; 74(3):684-93. PubMed ID: 25242318 [TBL] [Abstract][Full Text] [Related]
25. Composite pulses for RF phase encoded MRI: A simulation study. Salajeghe S; Babyn P; Sarty GE Magn Reson Imaging; 2017 Feb; 36():40-48. PubMed ID: 27743871 [TBL] [Abstract][Full Text] [Related]
26. Optimal control design of band-selective excitation pulses that accommodate relaxation and RF inhomogeneity. Skinner TE; Gershenzon NI; Nimbalkar M; Glaser SJ J Magn Reson; 2012 Apr; 217():53-60. PubMed ID: 22425442 [TBL] [Abstract][Full Text] [Related]
27. Spin-lattice relaxation and a fast T1-map acquisition method in MRI with transient-state magnetization. Hsu JJ; Lowe IJ J Magn Reson; 2004 Aug; 169(2):270-8. PubMed ID: 15261622 [TBL] [Abstract][Full Text] [Related]
28. Broadband CPMG sequence with short composite refocusing pulses. Koroleva VD; Mandal S; Song YQ; Hürlimann MD J Magn Reson; 2013 May; 230():64-75. PubMed ID: 23454575 [TBL] [Abstract][Full Text] [Related]
29. A convenient method for calibration of the pulse-length in high field-gradients using Hahn echo-trains. Randall EW Solid State Nucl Magn Reson; 1997 May; 8(3):179-83. PubMed ID: 9211622 [TBL] [Abstract][Full Text] [Related]
30. The chemical shift interaction under weak radio frequency pulses. Ding S; Ye C Solid State Nucl Magn Reson; 1992 Dec; 1(5):235-43. PubMed ID: 1365737 [TBL] [Abstract][Full Text] [Related]
31. Chebyshev series for designing RF pulses employing an optimal control approach. Ulloa JL; Guarini M; Guesalaga A; Irarrazaval P IEEE Trans Med Imaging; 2004 Nov; 23(11):1445-52. PubMed ID: 15554131 [TBL] [Abstract][Full Text] [Related]