187 related articles for article (PubMed ID: 9327608)
1. Measurement of venous oxyhaemoglobin saturation in the adult human forearm by near infrared spectroscopy with venous occlusion.
Yoxall CW; Weindling AM
Med Biol Eng Comput; 1997 Jul; 35(4):331-6. PubMed ID: 9327608
[TBL] [Abstract][Full Text] [Related]
2. The measurement of peripheral venous oxyhemoglobin saturation in newborn infants by near infrared spectroscopy with venous occlusion.
Yoxall CW; Weindling AM
Pediatr Res; 1996 Jun; 39(6):1103-6. PubMed ID: 8725277
[TBL] [Abstract][Full Text] [Related]
3. A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients.
Tortoriello TA; Stayer SA; Mott AR; McKenzie ED; Fraser CD; Andropoulos DB; Chang AC
Paediatr Anaesth; 2005 Jun; 15(6):495-503. PubMed ID: 15910351
[TBL] [Abstract][Full Text] [Related]
4. Forearm and calf tissue oxygenation in term neonates measured with near-infrared spectroscopy.
Pichler G; Heinzinger J; Kutschera J; Zotter H; Müller W; Urlesberger B
J Physiol Sci; 2007 Oct; 57(5):317-9. PubMed ID: 17916280
[TBL] [Abstract][Full Text] [Related]
5. Measurement of regional forearm muscle haemodynamics via the near-infrared spectroscopy venous occlusion technique: the impact of hand circulatory occlusion.
Cross TJ; van Beekvelt M; Constantini K; Sabapathy S
Physiol Meas; 2014 Dec; 35(12):2563-73. PubMed ID: 25419965
[TBL] [Abstract][Full Text] [Related]
6. Noninvasive optical quantification of cerebral venous oxygen saturation in humans.
Lynch JM; Buckley EM; Schwab PJ; Busch DR; Hanna BD; Putt ME; Licht DJ; Yodh AG
Acad Radiol; 2014 Feb; 21(2):162-7. PubMed ID: 24439329
[TBL] [Abstract][Full Text] [Related]
7. Use of near infrared spectroscopy for estimation of peripheral venous saturation in newborns: comparison with co-oximetry of central venous blood.
Bay-Hansen R; Elfving B; Greisen G
Biol Neonate; 2002; 82(1):1-8. PubMed ID: 12119534
[TBL] [Abstract][Full Text] [Related]
8. Muscle metabolism from near infrared spectroscopy during rhythmic handgrip in humans.
Boushel R; Pott F; Madsen P; Rådegran G; Nowak M; Quistorff B; Secher N
Eur J Appl Physiol Occup Physiol; 1998 Dec; 79(1):41-8. PubMed ID: 10052659
[TBL] [Abstract][Full Text] [Related]
9. T
Alderliesten T; De Vis JB; Lemmers PMA; van Bel F; Benders MJNL; Hendrikse J; Petersen ET
Neuroimage; 2016 Oct; 139():65-73. PubMed ID: 27291495
[TBL] [Abstract][Full Text] [Related]
10. The impact of venous occlusion per se on forearm muscle blood flow: implications for the near-infrared spectroscopy venous occlusion technique.
Cross TJ; Sabapathy S
Clin Physiol Funct Imaging; 2017 May; 37(3):293-298. PubMed ID: 26427913
[TBL] [Abstract][Full Text] [Related]
11. Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry.
Van Keer K; Van Keer J; Barbosa Breda J; Nassiri V; De Deyne C; Genbrugge C; Abegão Pinto L; Stalmans I; Vandewalle E
PLoS One; 2018; 13(1):e0190612. PubMed ID: 29304150
[TBL] [Abstract][Full Text] [Related]
12. Measurement of oxygen saturation in venous blood by dynamic near infrared spectroscopy.
Nitzan M; Babchenko A; Khanokh B; Taitelbaum H
J Biomed Opt; 2000 Apr; 5(2):155-62. PubMed ID: 10938779
[TBL] [Abstract][Full Text] [Related]
13. Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion.
Abay TY; Kyriacou PA
IEEE Trans Biomed Eng; 2015 Sep; 62(9):2187-95. PubMed ID: 25838515
[TBL] [Abstract][Full Text] [Related]
14. A method to calculate arterial and venous saturation from near infrared spectroscopy (NIRS).
Menssen J; Colier W; Hopman J; Liem D; de Korte C
Adv Exp Med Biol; 2009; 645():135-40. PubMed ID: 19227462
[TBL] [Abstract][Full Text] [Related]
15. Noninvasive measurement of cerebral hemoglobin oxygen saturation using two near infrared spectroscopy approaches.
Quaresima V; Sacco S; Totaro R; Ferrari M
J Biomed Opt; 2000 Apr; 5(2):201-5. PubMed ID: 10938784
[TBL] [Abstract][Full Text] [Related]
16. Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy.
Edwards AD; Richardson C; van der Zee P; Elwell C; Wyatt JS; Cope M; Delpy DT; Reynolds EO
J Appl Physiol (1985); 1993 Oct; 75(4):1884-9. PubMed ID: 8282646
[TBL] [Abstract][Full Text] [Related]
17. Combination of different noninvasive measuring techniques: a new approach to increase accuracy of peripheral near infrared spectroscopy.
Pichler G; Grossauer K; Peichl E; Gaster A; Berghold A; Schwantzer G; Zotter H; Müller W; Urlesberger B
J Biomed Opt; 2009; 14(1):014014. PubMed ID: 19256702
[TBL] [Abstract][Full Text] [Related]
18. Noninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy.
De Blasi RA; Ferrari M; Natali A; Conti G; Mega A; Gasparetto A
J Appl Physiol (1985); 1994 Mar; 76(3):1388-93. PubMed ID: 8005887
[TBL] [Abstract][Full Text] [Related]
19. The Various Oximetric Techniques Used for the Evaluation of Blood Oxygenation.
Nitzan M; Nitzan I; Arieli Y
Sensors (Basel); 2020 Aug; 20(17):. PubMed ID: 32867184
[TBL] [Abstract][Full Text] [Related]
20. Noninvasive tracking of mixed venous oxygen saturation via near-infrared spectroscopy cerebral oximetry: a retrospective observational study.
Oh C; Baek S; Lee S; Shim MS; Han SJ; Kim YH; Lee JY; Ku Y; Hong B
Sci Rep; 2023 Dec; 13(1):21704. PubMed ID: 38066206
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]