These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 9330447)

  • 1. A study of the spectral broadening of simulated Doppler signals using FFT and AR modelling.
    Keeton PI; Schlindwein FS; Evans DH
    Ultrasound Med Biol; 1997; 23(7):1033-45. PubMed ID: 9330447
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Spectral broadening of clinical Doppler signals using FFT and autoregressive modelling.
    Keeton PI; Schlindwein FS
    Eur J Ultrasound; 1998 Aug; 7(3):209-18. PubMed ID: 9700218
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Spectral analysis of internal carotid arterial Doppler signals using FFT, AR, MA, and ARMA methods.
    Ubeyli ED; Güler I
    Comput Biol Med; 2004 Jun; 34(4):293-306. PubMed ID: 15121001
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Doppler angle estimation using AR modeling.
    Yeh CK; Li PC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Jun; 49(6):683-92. PubMed ID: 12075962
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Compound Doppler ultrasound signal simulation for pulsatile carotid arteries with a stenosis.
    Gao L; Zhang Y; Zhou Y; Hu X; Deng L; Zhang K; Cai G; Zhang J
    Biomed Mater Eng; 2016 Aug; 27(2-3):131-48. PubMed ID: 27567770
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparative study and assessment of Doppler ultrasound spectral estimation techniques. Part II: Methods and results.
    Vaitkus PJ; Cobbold RS; Johnston KW
    Ultrasound Med Biol; 1988; 14(8):673-88. PubMed ID: 3062863
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Factors affecting the continuous wave Doppler spectrum for the diagnosis of carotid arterial disease.
    Morin JF; Johnston KW; Law YF
    Ultrasound Med Biol; 1988; 14(3):175-89. PubMed ID: 3289222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Doppler angle estimation of pulsatile flows using AR modeling.
    Yeh CK; Li PC
    Ultrason Imaging; 2002 Apr; 24(2):65-80. PubMed ID: 12199419
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multigate doppler signal analysis using 3-D regularized long AR modelling.
    Berthomier C; Herment A; Giovannelli JF; Guidi G; Pourcelot L; Diebold B
    Ultrasound Med Biol; 2001 Nov; 27(11):1515-23. PubMed ID: 11750751
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the autoregressive modeling and fast Fourier transformation in demonstrating Doppler spectral waveform changes in the early phase of atherosclerosis.
    Dirgenali F; Kara S; Erdogan N; Okandan M
    Comput Biol Med; 2005 Jan; 35(1):57-66. PubMed ID: 15567352
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of fast Fourier transformation and autoregressive modelling as a diagnostic tool in analysis of lower extremity venous signals.
    Kara S; Kemaloglu S; Erdogan N
    Comput Biol Med; 2006 May; 36(5):484-94. PubMed ID: 15922320
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adaptive Spectral Envelope Estimation for Doppler Ultrasound.
    Kathpalia A; Karabiyik Y; Eik-Nes SH; Tegnander E; Ekroll IK; Kiss G; Torp H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Nov; 63(11):1825-1838. PubMed ID: 27824563
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modern spectral analysis techniques for blood flow velocity and spectral measurements with pulsed Doppler ultrasound.
    David JY; Jones SA; Giddens DP
    IEEE Trans Biomed Eng; 1991 Jun; 38(6):589-96. PubMed ID: 1879848
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of stenosis and occlusion in arteries with the application of FFT, AR, and ARMA methods.
    Ubeyli ED; Güler I
    J Med Syst; 2003 Apr; 27(2):105-20. PubMed ID: 12617353
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Autoregressive-based sonogram outputs of 20 MHz pulsed Doppler data.
    Güler NF; Kiymik MK; Güler I
    Med Prog Technol; 1995 May; 21(2):105-10. PubMed ID: 7565395
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of the hemodynamic factors which influence the carotid Doppler spectral broadening.
    Douville Y; Johnston KW; Kassam M
    Ultrasound Med Biol; 1985; 11(3):417-23. PubMed ID: 2931873
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spectral broadening of ophthalmic arterial Doppler signals using STFT and wavelet transform.
    Ubeyli ED; Güler I
    Comput Biol Med; 2004 Jun; 34(4):345-54. PubMed ID: 15121004
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of fast Fourier transform (FFT) and autoregressive (AR) spectral estimation techniques for the analysis of tremor data.
    Spyers-Ashby JM; Bain PG; Roberts SJ
    J Neurosci Methods; 1998 Aug; 83(1):35-43. PubMed ID: 9765049
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of autoregressive methods to multigate spectral analysis.
    Guidi G; Corti L; Tortoli P
    Ultrasound Med Biol; 2000 May; 26(4):585-92. PubMed ID: 10856621
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of Doppler signal analysis techniques for velocity waveform, turbulence and vortex measurement: a simulation study.
    Wang Y; Fish PJ
    Ultrasound Med Biol; 1996; 22(5):635-49. PubMed ID: 8865559
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.