These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 9350714)

  • 41. Positioning of a plane-parallel ionization chamber in clinical electron beams and the impact on perturbation factors.
    Zink K; Wulff J
    Phys Med Biol; 2009 Apr; 54(8):2421-35. PubMed ID: 19336840
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Direct measurement of electron beam quality conversion factors using water calorimetry.
    Renaud J; Sarfehnia A; Marchant K; McEwen M; Ross C; Seuntjens J
    Med Phys; 2015 Nov; 42(11):6357-68. PubMed ID: 26520727
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Experimental study on the influence of the central electrode in Farmer-type ionization chambers.
    Palm A; Mattsson O
    Phys Med Biol; 1999 May; 44(5):1299-308. PubMed ID: 10368020
    [TBL] [Abstract][Full Text] [Related]  

  • 44. On the p(dis) correction factor for cylindrical chambers.
    Andreo P
    Phys Med Biol; 2010 Mar; 55(5):L9-16; author reply L17-9. PubMed ID: 20157227
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Electron beam quality k(Q,Q0) factors for various ionization chambers: a Monte Carlo investigation with PENELOPE.
    Erazo F; Brualla L; Lallena AM
    Phys Med Biol; 2014 Nov; 59(21):6673-91. PubMed ID: 25325343
    [TBL] [Abstract][Full Text] [Related]  

  • 46. An empirical method for the determination of wall perturbation factors for parallel-plate chambers in high-energy electron beams.
    McEwen M; Palmans H; Williams A
    Phys Med Biol; 2006 Oct; 51(20):5167-81. PubMed ID: 17019031
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A Monte Carlo simulation framework for electron beam dose calculations using Varian phase space files for TrueBeam Linacs.
    Rodrigues A; Sawkey D; Yin FF; Wu Q
    Med Phys; 2015 May; 42(5):2389-403. PubMed ID: 25979034
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Calculation of stopping-power ratios using realistic clinical electron beams.
    Ding GX; Rogers DW; Mackie TR
    Med Phys; 1995 May; 22(5):489-501. PubMed ID: 7643785
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.
    Dalaryd M; Knöös T; Ceberg C
    Med Phys; 2014 Nov; 41(11):111716. PubMed ID: 25370630
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparison of PENELOPE Monte Carlo dose calculations with Fricke dosimeter and ionization chamber measurements in heterogeneous phantoms (18 MeV electron and 12 MV photon beams).
    Blazy L; Baltes D; Bordy JM; Cutarella D; Delaunay F; Gouriou J; Leroy E; Ostrowsky A; Beaumont S
    Phys Med Biol; 2006 Nov; 51(22):5951-65. PubMed ID: 17068376
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Measured and Monte Carlo calculated K(Q) factors: accuracy and comparison.
    Muir BR; McEwen MR; Rogers DW
    Med Phys; 2011 Aug; 38(8):4600-9. PubMed ID: 21928633
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Technical note: Bremsstrahlung dose in the electron beam at extended distances in total skin electron therapy.
    Ding GX; Kucuker-Dogan S; Das IJ
    Med Phys; 2022 Feb; 49(2):1297-1302. PubMed ID: 34964133
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Determination of percentage depth-dose curves for electron beams using different types of detectors.
    Ding GX; Yu CW
    Med Phys; 2001 Mar; 28(3):298-302. PubMed ID: 11318309
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparing the dosimeter-specific corrections for influence quantities of some parallel-plate ionization chambers in conventional electron beam dosimetry.
    Baghani HR; Robatjazi M; Andreoli S
    Appl Radiat Isot; 2022 Jan; 179():110031. PubMed ID: 34801928
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry.
    Araki F; Hanyu Y; Fukuoka M; Matsumoto K; Okumura M; Oguchi H
    Med Phys; 2009 Jul; 36(7):2992-3001. PubMed ID: 19673198
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The use of 0.5r
    Anusionwu PC; Alpuche Aviles JE; Pistorius S
    J Appl Clin Med Phys; 2020 Jan; 21(1):117-126. PubMed ID: 31898872
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Performance analysis and determination of the p(wall) correction factor for 60Co gamma-ray beams for Wellhöfer Roos-type plane-parallel chambers.
    Palm A; Czap L; Andreo P; Mattsson O
    Phys Med Biol; 2002 Feb; 47(4):631-40. PubMed ID: 11900195
    [TBL] [Abstract][Full Text] [Related]  

  • 58. kQ factors for ionization chamber dosimetry in clinical proton beams.
    Vatnitsky SM; Siebers JV; Miller DW
    Med Phys; 1996 Jan; 23(1):25-31. PubMed ID: 8700030
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A comparison of methods for calibrating parallel-plate chambers/.
    Reft CS; Kuchnir FT; DeWerd LA; Micka J; Attix FH
    Med Phys; 1994 Dec; 21(12):1953-7. PubMed ID: 7700203
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Extracting W
    Tessier F; Cojocaru CD; Ross CK
    Med Phys; 2018 Jan; 45(1):370-381. PubMed ID: 29131343
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.