These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

283 related articles for article (PubMed ID: 9352760)

  • 1. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing.
    Aerts JG; van den Berg B; Bogaard JM
    Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning.
    Patel RG; Petrini MF
    Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inspiratory work imposed by continuous positive airway pressure (CPAP) machines: the effect of CPAP level and endotracheal tube size.
    Moran JL; Homan S; O'Fathartaigh M; Jackson M; Leppard P
    Intensive Care Med; 1992; 18(3):148-54. PubMed ID: 1644962
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in severe chronic obstructive pulmonary disease.
    Petrof BJ; Legaré M; Goldberg P; Milic-Emili J; Gottfried SB
    Am Rev Respir Dis; 1990 Feb; 141(2):281-9. PubMed ID: 2405757
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of low-level PEEP on inspiratory work of breathing in intubated patients, both with healthy lungs and with COPD.
    Sydow M; Golisch W; Buscher H; Zinserling J; Crozier TA; Burchardi H
    Intensive Care Med; 1995 Nov; 21(11):887-95. PubMed ID: 8636520
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved flow and pressure capabilities of the Datex-Ohmeda SmartVent anesthesia ventilator.
    Katz JA; Kallet RH; Alonso JA; Marks JD
    J Clin Anesth; 2000 Feb; 12(1):40-7. PubMed ID: 10773507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of imposed resistance on tidal volume with 5 neonatal nasal continuous positive airway pressure systems.
    Cook SE; Fedor KL; Chatburn RL
    Respir Care; 2010 May; 55(5):544-8. PubMed ID: 20420723
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Superimposed inspiratory work of the Siemens Servo 300 ventilator during continuous positive airway pressure.
    Tan IK; Bhatt SB; Tam YH; Buckley TA; Oh TE
    Intensive Care Med; 1995 Dec; 21(12):1023-6. PubMed ID: 8750128
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators].
    Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J
    Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system.
    Banner MJ; Blanch PB; Kirby RR
    Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467
    [TBL] [Abstract][Full Text] [Related]  

  • 12. CPAP with a Siemens Servo 900C ventilator during weaning in infants.
    Radermacher P; Breulmann M; Felber HJ; Santak B
    Intensive Care Med; 1991; 17(3):189. PubMed ID: 2071772
    [No Abstract]   [Full Text] [Related]  

  • 13. [Added work of breathing, respiratory pattern and determination of ventilator weaning readiness in inspiratory pressure support and and automatic tube compensation].
    Stocker R; Fabry B; Stein S; Zappe D; Trentz O; Haberthür C
    Unfallchirurg; 1996 Oct; 99(10):764-70. PubMed ID: 9005565
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of disposable or interchangeable positive end-expiratory pressure valves on work of breathing during the application of continuous positive airway pressure.
    Kacmarek RM; Mang H; Barker N; Cycyk-Chapman MC
    Crit Care Med; 1994 Aug; 22(8):1219-26. PubMed ID: 8045140
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pressure characteristics of the Ambu CPAP system and the Servo ventilator 900C in CPAP mode.
    Zetterström H; Jonsson LO
    Acta Anaesthesiol Scand; 1987 Jan; 31(1):104-10. PubMed ID: 3548197
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of pressure support in compensating for apparatus work.
    Bersten AD; Rutten AJ; Vedig AE
    Anaesth Intensive Care; 1993 Feb; 21(1):67-71. PubMed ID: 8447610
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pressure-time product and work of breathing during biphasic continuous positive airway pressure and assisted spontaneous breathing.
    Calzia E; Lindner KH; Witt S; Schirmer U; Lange H; Stenz R; Georgieff M
    Am J Respir Crit Care Med; 1994 Oct; 150(4):904-10. PubMed ID: 7921461
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Total inspiratory work with modern demand valve devices compared to continuous flow CPAP.
    Samodelov LF; Falke KJ
    Intensive Care Med; 1988; 14(6):632-9. PubMed ID: 3053843
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Additional inspiratory work of breathing imposed by tracheostomy tubes and non-ideal ventilator properties in critically ill patients.
    Haberthür C; Fabry B; Stocker R; Ritz R; Guttmann J
    Intensive Care Med; 1999 May; 25(5):514-9. PubMed ID: 10401948
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inspiratory muscle work of breathing during flow-by, demand-flow, and continuous-flow systems in patients with chronic obstructive pulmonary disease.
    Sassoon CS; Lodia R; Rheeman CH; Kuei JH; Light RW; Mahutte CK
    Am Rev Respir Dis; 1992 May; 145(5):1219-22. PubMed ID: 1586070
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.