These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 9353429)

  • 1. Dosimetric aspects of physical and dynamic wedge of Clinac 2100C linear accelerator.
    Avadhani JS; Pradhan AS; Sankar A; Viswanathan PS
    Strahlenther Onkol; 1997 Oct; 173(10):524-8. PubMed ID: 9353429
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams.
    Shamsi A; Tahmasebi Birgani MJ; Behrooz MA; Arvandi S; Fatahiasl J; Maskny R; Abdalvand N
    Asian Pac J Cancer Prev; 2016; 17(1):197-200. PubMed ID: 26838209
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multienergetic verification of dynamic wedge angles in medical accelerators using multichannel linear array.
    Kowalik A; Litoborski M
    Rep Pract Oncol Radiother; 2013; 18(4):220-34. PubMed ID: 24416557
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear accelerators.
    Bidmead AM; Garton AJ; Childs PJ
    Phys Med Biol; 1995 Mar; 40(3):393-411. PubMed ID: 7732070
    [TBL] [Abstract][Full Text] [Related]  

  • 5. "Dosimetric aspects of physical and dynamic wedges of the Clinac 2100C Linear Accelerator". Comment on the publication of J.S. Avadhani et al. in Strahlenther Onkol 1997; 173:524-28 (no. 10).
    Wiezorek T; Harder D
    Strahlenther Onkol; 1998 Feb; 174(2):105. PubMed ID: 9487373
    [No Abstract]   [Full Text] [Related]  

  • 6. Dosimetric Characteristics of 6 MV Modified Beams by Physical Wedges of a Siemens Linear Accelerator.
    Zabihzadeh M; Birgani MJ; Hoseini-Ghahfarokhi M; Arvandi S; Hoseini SM; Fadaei M
    Asian Pac J Cancer Prev; 2016; 17(4):1685-9. PubMed ID: 27221838
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetry and clinical implementation of dynamic wedge.
    Klein EE; Low DA; Meigooni AS; Purdy JA
    Int J Radiat Oncol Biol Phys; 1995 Feb; 31(3):583-92. PubMed ID: 7852124
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surface and peripheral doses of dynamic and physical wedges.
    Li Z; Klein EE
    Int J Radiat Oncol Biol Phys; 1997 Mar; 37(4):921-5. PubMed ID: 9128970
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric parameters of a modified set of wedges for use with asymmetric fields of a 6 MV linear accelerator.
    Niroomand-Rad A; Rodgers JE; Taylor P; Hames B
    Med Phys; 1994 Sep; 21(9):1405-8. PubMed ID: 7838051
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multiple machine implementation of enhanced dynamic wedge.
    Klein EE; Gerber R; Zhu XR; Oehmke F; Purdy JA
    Int J Radiat Oncol Biol Phys; 1998 Mar; 40(4):977-85. PubMed ID: 9531384
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of a multileaf collimator to increase the field width achievable with a dynamic wedge.
    Brezovich IA; Popple RA; Duan J
    J Appl Clin Med Phys; 2006 Aug; 7(3):35-42. PubMed ID: 17533337
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric characteristics of wedges mounted beyond the blocking tray.
    Ochran TG; Boyer AL; Nyerick CE; Otte VA
    Med Phys; 1992; 19(1):187-94. PubMed ID: 1620046
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The dependency of wedge factors on field size and depth in megavoltage beams.
    Avadhani JS; Pradhan AS; Sankar A; Viswanathan PS
    Strahlenther Onkol; 1996 Nov; 172(11):626-30. PubMed ID: 8946032
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiotherapy treatment planning with dynamic wedges--an algorithm for generating wedge factors and beam data.
    Thomas SJ; Foster KR
    Phys Med Biol; 1995 Sep; 40(9):1421-33. PubMed ID: 8532756
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evidence for a significantly higher than expected depth dependence of wedge transmission factors on the 4 MV beam of a new dual energy accelerator.
    Biggs PJ; Beatty J; Radloff J
    Med Phys; 1998 Nov; 25(11):2234-6. PubMed ID: 9829251
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wedge factor dependence with depth, field size, and nominal distance--a general computational rule.
    Popescu A; Lai K; Singer K; Phillips M
    Med Phys; 1999 Apr; 26(4):541-9. PubMed ID: 10227357
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric parameters of enhanced dynamic wedge for treatment planning and verification.
    Leavitt DD; Lee WL; Gaffney DK; Moeller JH; O'Rear JH
    Med Dosim; 1997; 22(3):177-83. PubMed ID: 9307947
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of dosimetric characteristics of Siemens virtual and physical wedges.
    Zhu XR; Gillin MT; Jursinic PA; Lopez F; Grimm DF; Rownd JJ
    Med Phys; 2000 Oct; 27(10):2267-77. PubMed ID: 11099193
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Peripheral dose from a dual energy linear accelerator equipped with tertiary multileaf collimators and enhanced dynamic wedge.
    Varatharaj C; Ravikumar M; Sathiyan S; Supe SS
    Gulf J Oncolog; 2011 Jan; (9):27-35. PubMed ID: 21177206
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Studying wedge factors and beam profiles for physical and enhanced dynamic wedges.
    Ahmad M; Hussain A; Muhammad W; Rizvi SQ; Matiullah
    J Med Phys; 2010 Jan; 35(1):33-41. PubMed ID: 20177568
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.