BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 9355594)

  • 1. The use of heparin and normal saline flushes in neonatal intravenous catheters.
    Paisley MK; Stamper M; Brown J; Brown N; Ganong LH
    Pediatr Nurs; 1997; 23(5):521-4, 527. PubMed ID: 9355594
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Patency of 24-gauge peripheral intermittent infusion devices: a comparison of heparin and saline flush solutions.
    Mudge B; Forcier D; Slattery MJ
    Pediatr Nurs; 1998; 24(2):142-5, 149. PubMed ID: 9697567
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effectiveness of heparin solution versus normal saline in maintaining patency of intravenous locks in neonates: a double blind randomized controlled study.
    Arnts IJ; Heijnen JA; Wilbers HT; van der Wilt GJ; Groenewoud JM; Liem KD
    J Adv Nurs; 2011 Dec; 67(12):2677-85. PubMed ID: 21722168
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heparinized saline vs normal saline for maintenance of intravenous access in neonates: an evidence-based practice change.
    Cook L; Bellini S; Cusson RM
    Adv Neonatal Care; 2011 Jun; 11(3):208-15. PubMed ID: 21730915
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Heparin vs saline for intermittent intravenous device maintenance in neonates.
    Kotter RW
    Neonatal Netw; 1996 Sep; 15(6):43-7. PubMed ID: 8932071
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the effects of heparinized and nonheparinized flush solutions on the patency of arterial pressure monitoring lines: the AACN Thunder Project. By the American Association of Critical-Care Nurses.
    Am J Crit Care; 1993 Jan; 2(1):3-15. PubMed ID: 8353575
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Heparin versus normal saline as a peripheral line flush in maintenance of intermittent intravenous lines in obstetric patients.
    Meyer BA; Little CJ; Thorp JA; Cohen GR; Yeast JD
    Obstet Gynecol; 1995 Mar; 85(3):433-6. PubMed ID: 7862386
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Heparin sodium versus 0.9% sodium chloride injection for maintaining patency of indwelling intermittent infusion devices.
    Hamilton RA; Plis JM; Clay C; Sylvan L
    Clin Pharm; 1988 Jun; 7(6):439-43. PubMed ID: 3402178
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Heparin vs. saline for peripheral i.v. locks in children.
    Kleiber C; Hanrahan K; Fagan CL; Zittergruen MA
    Pediatr Nurs; 1993; 19(4):405-9, 376. PubMed ID: 8414730
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Heparinized saline or normal saline as a flush solution in intermittent intravenous lines in infants and children.
    McMullen A; Fioravanti ID; Pollack V; Rideout K; Sciera M
    MCN Am J Matern Child Nurs; 1993; 18(2):78-85. PubMed ID: 8492651
    [No Abstract]   [Full Text] [Related]  

  • 11. A randomized controlled trial for maintaining peripheral intravenous lock in children.
    Mok E; Kwong TK; Chan MF
    Int J Nurs Pract; 2007 Feb; 13(1):33-45. PubMed ID: 17244243
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of heparin versus saline solution on intermittent infusion device irrigation.
    Ashton J; Gibson V; Summers S
    Heart Lung; 1990 Nov; 19(6):608-12. PubMed ID: 2228650
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Patency of arterial catheters with heparinized solutions versus non-heparinized solutions: a review of the literature.
    Lapum JL
    Can J Cardiovasc Nurs; 2006; 16(2):64-70. PubMed ID: 17153134
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Examining the effectiveness of 2 solutions used to flush capped pediatric peripheral intravenous catheters.
    White ML; Crawley J; Rennie EA; Lewandowski LA
    J Infus Nurs; 2011; 34(4):260-70. PubMed ID: 21734522
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.
    Schallom ME; Prentice D; Sona C; Micek ST; Skrupky LP
    Crit Care Med; 2012 Jun; 40(6):1820-6. PubMed ID: 22488006
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A meta-analysis of effects of heparin flush and saline flush: quality and cost implications.
    Goode CJ; Titler M; Rakel B; Ones DS; Kleiber C; Small S; Triolo PK
    Nurs Res; 1991; 40(6):324-30. PubMed ID: 1835537
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Efficacy of normal saline solution versus heparin solution for maintaining patency of peripheral intravenous catheters in children.
    LeDuc K
    J Emerg Nurs; 1997 Aug; 23(4):306-9. PubMed ID: 9379571
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Heparinized saline versus normal saline in maintaining patency of the radial artery catheter.
    Kulkarni M; Elsner C; Ouellet D; Zeldin R
    Can J Surg; 1994 Feb; 37(1):37-42. PubMed ID: 8306218
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Keeping central venous lines open: a prospective comparison of heparin, vitamin C and sodium chloride sealing solutions in medical patients.
    Rabe C; Gramann T; Sons X; Berna M; González-Carmona MA; Klehr HU; Sauerbruch T; Caselmann WH
    Intensive Care Med; 2002 Aug; 28(8):1172-6. PubMed ID: 12185445
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of saline vs heparin in maintaining 24-gauge intermittent intravenous catheters in a rabbit model.
    Kyle LA; Turner BS
    Neonatal Netw; 1999 Sep; 18(6):49-54. PubMed ID: 10690098
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.