BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 9360087)

  • 1. Porcine aortic wall flexibility. Fresh vs Denacol fixed vs glutaraldehyde fixed.
    Zhou J; Quintero LJ; Helmus MN; Lee C; Kafesjian R
    ASAIO J; 1997; 43(5):M470-5. PubMed ID: 9360087
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of the cross-linking characteristics of porcine heart valves fixed with glutaraldehyde or epoxy compounds.
    Sung HW; Shen SH; Tu R; Lin D; Hata C; Noishiki Y; Tomizawa Y; Quijano RC
    ASAIO J; 1993; 39(3):M532-6. PubMed ID: 8268592
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization of a polyepoxy compound fixed porcine heart valve bioprosthesis.
    Shen SH; Sung HW; Tu R; Hata C; Lin D; Noishiki Y; Quijano RC
    J Appl Biomater; 1994; 5(2):159-62. PubMed ID: 10147176
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of sizing and method of fixation on the hydrodynamic function of stentless, free-hand inserted porcine bioprosthesis: an in vitro study.
    Revanna P; Fisher J; Watterson KG
    J Heart Valve Dis; 1997 Jul; 6(4):433-8. PubMed ID: 9263877
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of stenting on the behavior of amino-oleic acid-treated, glutaraldehyde-fixed porcine aortic valves in a sheep model.
    Ozaki S; Herijgers P; Verbeken E; Van Lommel A; Nishida T; Perek B; Zietkiewicz M; Leunens V; Flameng W
    J Heart Valve Dis; 2000 Jul; 9(4):552-9; discussion 559-60. PubMed ID: 10947049
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Degeneration of bioprosthetic heart valve cusp and wall tissues is initiated during tissue preparation: an ultrastructural study.
    Simionescu DT; Lovekamp JJ; Vyavahare NR
    J Heart Valve Dis; 2003 Mar; 12(2):226-34. PubMed ID: 12701796
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Physiological function of stentless aortic valves is altered by trimming and removal of aortic wall components.
    Kuehnel RU; Stock UA; Wendt MO; Degenkolbe I; Jainski U; Hartrumpf M; Pohl M; Albes JM
    Interact Cardiovasc Thorac Surg; 2007 Apr; 6(2):182-7. PubMed ID: 17669805
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The pulmonary bioprosthetic heart valve: its unsuitability for use as an aortic valve replacement.
    Jennings LM; Butterfield M; Booth C; Watterson KG; Fisher J
    J Heart Valve Dis; 2002 Sep; 11(5):668-78; discussion 679. PubMed ID: 12358404
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Amide cross-linking: an alternative to glutaraldehyde fixation.
    Girardot JM; Girardot MN
    J Heart Valve Dis; 1996 Sep; 5(5):518-25. PubMed ID: 8894992
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Extracellular matrix degrading enzymes are active in porcine stentless aortic bioprosthetic heart valves.
    Simionescu DT; Lovekamp JJ; Vyavahare NR
    J Biomed Mater Res A; 2003 Sep; 66(4):755-63. PubMed ID: 12926026
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep].
    Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diamine-extended glutaraldehyde- and carbodiimide crosslinks act synergistically in mitigating bioprosthetic aortic wall calcification.
    Zilla P; Bezuidenhout D; Torrianni M; Hendriks M; Human P
    J Heart Valve Dis; 2005 Jul; 14(4):538-45. PubMed ID: 16116882
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fixation-related autolysis and bioprosthetic aortic wall calcification.
    Human P; Weissenstein C; Trantina A; Zilla P
    J Heart Valve Dis; 2001 Sep; 10(5):656-65. PubMed ID: 11603606
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inflammation and infection in nine surgically explanted Medtronic Freestyle stentless aortic valves.
    Butany J; Zhou T; Leong SW; Cunningham KS; Thangaroopan M; Jegatheeswaran A; Feindel C; David TE
    Cardiovasc Pathol; 2007; 16(5):258-67. PubMed ID: 17868876
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Glutaraldehyde detoxification in addition to enhanced amine cross-linking dramatically reduces bioprosthetic tissue calcification in the rat model.
    Weissenstein C; Human P; Bezuidenhout D; Zilla P
    J Heart Valve Dis; 2000 Mar; 9(2):230-40. PubMed ID: 10772041
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Harvested porcine mitral xenograft fixation: impact on fluid dynamic performance.
    Jensen MO; Lemmon JD; Gessaghi VC; Conrad CP; Levine RA; Yoganathan AP
    J Heart Valve Dis; 2001 Jan; 10(1):111-24. PubMed ID: 11206757
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Glycosaminoglycan-degrading enzymes in porcine aortic heart valves: implications for bioprosthetic heart valve degeneration.
    Simionescu DT; Lovekamp JJ; Vyavahare NR
    J Heart Valve Dis; 2003 Mar; 12(2):217-25. PubMed ID: 12701795
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison between glutaraldehyde and diepoxide-fixed stentless porcine aortic valves: biochemical and mechanical characterization and resistance to mineralization.
    Myers DJ; Nakaya G; Girardot MN; Christie GW
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S98-101. PubMed ID: 8581221
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Role of glutaraldehyde in calcification of porcine heart valves: comparing cusp and wall.
    Girardot MN; Torrianni M; Dillehay D; Girardot JM
    J Biomed Mater Res; 1995 Jul; 29(7):793-801. PubMed ID: 7593017
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prevention of porcine aortic wall calcification by acellularization: necessity for a non-glutaraldehyde-based fixation treatment.
    Meuris B; Verbeken E; Flameng W
    J Heart Valve Dis; 2005 May; 14(3):358-63; discussion 363-4. PubMed ID: 15974531
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.