BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

405 related articles for article (PubMed ID: 9360143)

  • 21. Biocompatibility of a silicone-coated polypropylene hollow fiber oxygenator in an in vitro model.
    Watanabe H; Hayashi J; Ohzeki H; Moro H; Sugawara M; Eguchi S
    Ann Thorac Surg; 1999 May; 67(5):1315-9. PubMed ID: 10355404
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinical study of platelet function and coagulation/fibrinolysis with Duraflo II heparin coated cardiopulmonary bypass equipment.
    Nakajima T; Osawa S; Ogawa M; Sasaki T; Izumoto H; Yagi Y; Kawazoe K
    ASAIO J; 1996; 42(4):301-5. PubMed ID: 8828788
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pressure drop, shear stress, and activation of leukocytes during cardiopulmonary bypass: a comparison between hollow fiber and flat sheet membrane oxygenators.
    Gu YJ; Boonstra PW; Graaff R; Rijnsburger AA; Mungroop H; van Oeveren W
    Artif Organs; 2000 Jan; 24(1):43-8. PubMed ID: 10677156
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical evaluation of five commercially available adult oxygenators in terms of pressure drop during normothermic and hypothermic cardiopulmonary bypass.
    Ji B; Wang H; Miao N; Xing J; Liu W; Liu R; Long C
    Int J Artif Organs; 2010 May; 33(5):310-6. PubMed ID: 20593353
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates.
    Undar A; Owens WR; McGarry MC; Surprise DL; Kilpack VD; Mueller MW; McKenzie ED; Fraser CD
    Perfusion; 2005 May; 20(3):135-8. PubMed ID: 16038384
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Beneficial effects of Duraflo II heparin-coated circuits on postperfusion lung dysfunction.
    Ranucci M; Cirri S; Conti D; Ditta A; Boncilli A; Frigiola A; Menicanti L
    Ann Thorac Surg; 1996 Jan; 61(1):76-81. PubMed ID: 8561642
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery.
    Hoel TN; Videm V; Baksaas ST; Mollnes TE; Brosstad F; Svennevig JL
    Perfusion; 2004 May; 19(3):177-84. PubMed ID: 15298426
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biocompatibility of silicone-coated oxygenator in cardiopulmonary bypass.
    Shimamoto A; Kanemitsu S; Fujinaga K; Takao M; Onoda K; Shimono T; Tanaka K; Shimpo H; Yada I
    Ann Thorac Surg; 2000 Jan; 69(1):115-20. PubMed ID: 10654498
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Nafamostat mesilate reduces blood-foreign surface reactions similar to biocompatible materials.
    Usui A; Hiroura M; Kawamura M; Hibi M; Yoshida K; Murakami F; Tomita Y; Ooshima H; Murase M
    Ann Thorac Surg; 1996 Nov; 62(5):1404-11. PubMed ID: 8893576
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effects of ultrathin silicone coating of porous membrane on gas transfer and hemolytic performance.
    Niimi Y; Ueyama K; Yamaji K; Yamane S; Tayama E; Sueoka A; Kuwana K; Tahara K; Nosé Y
    Artif Organs; 1997 Oct; 21(10):1082-6. PubMed ID: 9335365
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Development of a new hollow fiber silicone membrane oxygenator for ECMO: the recent progress.
    Kawahito S; Motomura T; Glueck J; Nosé Y
    Ann Thorac Cardiovasc Surg; 2002 Oct; 8(5):268-74. PubMed ID: 12472408
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Silicone-coated polypropylene hollow-fiber oxygenator: experimental evaluation and preliminary clinical use.
    Shimono T; Shomura Y; Hioki I; Shimamoto A; Tenpaku H; Maze Y; Onoda K; Takao M; Shimpo H; Yada I
    Ann Thorac Surg; 1997 Jun; 63(6):1730-6. PubMed ID: 9205175
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The new advanced membrane gas exchanger.
    Berdajs DA; de Stefano E; Delay D; Ferrari E; Horisberger J; Ditmar Q; von Segesser LK
    Interact Cardiovasc Thorac Surg; 2011 Dec; 13(6):591-6. PubMed ID: 21835847
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biocompatibility of Trillium Biopassive Surface-coated oxygenator versus uncoated oxygenator during cardiopulmonary bypass.
    Ereth MH; Nuttall GA; Clarke SH; Dearani JA; Fiechtner BK; Rishavy CR; Buda DA; Shaw TA; Orszulak TA; Oliver WC
    J Cardiothorac Vasc Anesth; 2001 Oct; 15(5):545-50; discussion 539-41. PubMed ID: 11687991
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biocompatibility of a heparin-bonded membrane oxygenator (Carmeda MAXIMA) during the first 90 minutes of cardiopulmonary bypass: clinical comparison with the conventional system.
    Shigemitsu O; Hadama T; Takasaki H; Mori Y; Kimura T; Miyamoto S; Sako H; Soeda T; Kawawaki Y; Uchida Y
    Artif Organs; 1994 Dec; 18(12):936-41. PubMed ID: 7887832
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Complement activation during cardiopulmonary bypass. Comparison of bubble and membrane oxygenators.
    Cavarocchi NC; Pluth JR; Schaff HV; Orszulak TA; Homburger HA; Solis E; Kaye MP; Clancy MS; Kolff J; Deeb GM
    J Thorac Cardiovasc Surg; 1986 Feb; 91(2):252-8. PubMed ID: 3511328
    [TBL] [Abstract][Full Text] [Related]  

  • 37. New generation extracorporeal membrane oxygenation with MedTech Mag-Lev, a single-use, magnetically levitated, centrifugal blood pump: preclinical evaluation in calves.
    Fujiwara T; Nagaoka E; Watanabe T; Miyagi N; Kitao T; Sakota D; Mamiya T; Shinshi T; Arai H; Takatani S
    Artif Organs; 2013 May; 37(5):447-56. PubMed ID: 23489176
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biocompatibility of heparin-coated circuits in pediatric cardiopulmonary bypass.
    Kagisaki K; Masai T; Kadoba K; Sawa Y; Nomura F; Fukushima N; Ichikawa H; Ohata T; Suzuki K; Taketani S; Matsuda H
    Artif Organs; 1997 Jul; 21(7):836-40. PubMed ID: 9212969
    [TBL] [Abstract][Full Text] [Related]  

  • 39. New surface biopolymers for oxygenators: an in vitro hemocompatibility test of poly(2-methoxyethylacrylate).
    Baykut D; Bernet F; Wehrle J; Weichelt K; Schwartz P; Zerkowski HR
    Eur J Med Res; 2001 Jul; 6(7):297-305. PubMed ID: 11485890
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Development of a new silicone membrane oxygenator for ECMO.
    Nakata K; Maeda T; Murabayashi S; Yoshikawa M; Takano T; Iwasaki A; Nonaka K; Linneweber J; Kawahito S; Glueck J; Sato K; Kuwana J; Nosé Y
    Ann Thorac Cardiovasc Surg; 2000 Dec; 6(6):373-7. PubMed ID: 11173351
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.