These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
506 related articles for article (PubMed ID: 9368111)
1. Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint. Cohen-Bacrie C; Goussard Y; Guardo R IEEE Trans Med Imaging; 1997 Oct; 16(5):562-71. PubMed ID: 9368111 [TBL] [Abstract][Full Text] [Related]
2. Solution of the inverse problem of magnetic induction tomography (MIT). Merwa R; Hollaus K; Brunner P; Scharfetter H Physiol Meas; 2005 Apr; 26(2):S241-50. PubMed ID: 15798237 [TBL] [Abstract][Full Text] [Related]
3. [A hybrid reconstruction method in electrical impedance tomography based on GMRES and Tikhonov regularization]. Wang H; Fan W; Hu L Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Aug; 26(4):701-5. PubMed ID: 19813592 [TBL] [Abstract][Full Text] [Related]
4. [The selection of Tikhonov regularization parameter in dynamic electrical impedance imaging]. Peng Y; Mo Y Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Dec; 20(4):571-3. PubMed ID: 14716847 [TBL] [Abstract][Full Text] [Related]
5. Tikhonov regularization and prior information in electrical impedance tomography. Vauhkonen M; Vadász D; Karjalainen PA; Somersalo E; Kaipio JP IEEE Trans Med Imaging; 1998 Apr; 17(2):285-93. PubMed ID: 9688160 [TBL] [Abstract][Full Text] [Related]
6. Generation of anisotropic-smoothness regularization filters for EIT. Borsic A; Lionheart WR; McLeod CN IEEE Trans Med Imaging; 2002 Jun; 21(6):579-87. PubMed ID: 12166853 [TBL] [Abstract][Full Text] [Related]
7. Krylov subspace iterative techniques: on the detection of brain activity with electrical impedance tomography. Polydorides N; Lionheart WR; McCann H IEEE Trans Med Imaging; 2002 Jun; 21(6):596-603. PubMed ID: 12166855 [TBL] [Abstract][Full Text] [Related]
9. [Image reconstruction in electrical impedance tomography based on genetic algorithm]. Hou W; Mo Y Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Mar; 20(1):107-10. PubMed ID: 12744177 [TBL] [Abstract][Full Text] [Related]
10. A novel approach for EIT regularization via spatial and spectral principal component analysis. Goharian M; Bruwer MJ; Jegatheesan A; Moran GR; MacGregor JF Physiol Meas; 2007 Sep; 28(9):1001-16. PubMed ID: 17827649 [TBL] [Abstract][Full Text] [Related]
11. A method to solve the forward problem in magnetic induction tomography based on the weakly coupled field approximation. Dekdouk B; Yin W; Ktistis C; Armitage DW; Peyton AJ IEEE Trans Biomed Eng; 2010 Apr; 57(4):914-21. PubMed ID: 19932988 [TBL] [Abstract][Full Text] [Related]
12. Use of anisotropic modelling in electrical impedance tomography: description of method and preliminary assessment of utility in imaging brain function in the adult human head. Abascal JF; Arridge SR; Atkinson D; Horesh R; Fabrizi L; De Lucia M; Horesh L; Bayford RH; Holder DS Neuroimage; 2008 Nov; 43(2):258-68. PubMed ID: 18694835 [TBL] [Abstract][Full Text] [Related]
13. A measurement system and image reconstruction in magnetic induction tomography. Vauhkonen M; Hamsch M; Igney CH Physiol Meas; 2008 Jun; 29(6):S445-54. PubMed ID: 18544825 [TBL] [Abstract][Full Text] [Related]
14. A combined reconstruction-classification method for diffuse optical tomography. Hiltunen P; Prince SJ; Arridge S Phys Med Biol; 2009 Nov; 54(21):6457-76. PubMed ID: 19820265 [TBL] [Abstract][Full Text] [Related]
15. An iterative Newton-Raphson method to solve the inverse admittivity problem. Edic PM; Isaacson D; Saulnier GJ; Jain H; Newell JC IEEE Trans Biomed Eng; 1998 Jul; 45(7):899-908. PubMed ID: 9644899 [TBL] [Abstract][Full Text] [Related]
16. Electrical impedance tomography for piecewise constant domains using boundary element shape-based inverse solutions. Babaeizadeh S; Brooks DH IEEE Trans Med Imaging; 2007 May; 26(5):637-47. PubMed ID: 17518058 [TBL] [Abstract][Full Text] [Related]
17. Contrast and spatial resolution in MREIT using low amplitude current. Birgul O; Hamamura MJ; Muftuler LT; Nalcioglu O Phys Med Biol; 2006 Oct; 51(19):5035-49. PubMed ID: 16985286 [TBL] [Abstract][Full Text] [Related]
18. Measurement of ion diffusion using magnetic resonance electrical impedance tomography. Hamamura MJ; Muftuler LT; Birgul O; Nalcioglu O Phys Med Biol; 2006 Jun; 51(11):2753-62. PubMed ID: 16723764 [TBL] [Abstract][Full Text] [Related]
19. Stable reconstruction of piecewise continuous plane stratified biological tissues via electrical impedance tomography. Dolgin M; Einziger PD IEEE Trans Biomed Eng; 2010 May; 57(5):1227-33. PubMed ID: 20142149 [TBL] [Abstract][Full Text] [Related]
20. Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging. Woo EJ; Seo JK Physiol Meas; 2008 Oct; 29(10):R1-26. PubMed ID: 18799834 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]