These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
234 related articles for article (PubMed ID: 9368241)
1. Comparison of self-inflating bags with anesthesia bags for bag-mask ventilation in the pediatric emergency department. Mondolfi AA; Grenier BM; Thompson JE; Bachur RG Pediatr Emerg Care; 1997 Oct; 13(5):312-6. PubMed ID: 9368241 [TBL] [Abstract][Full Text] [Related]
2. A comparison of three neonatal resuscitation devices. Bennett S; Finer NN; Rich W; Vaucher Y Resuscitation; 2005 Oct; 67(1):113-8. PubMed ID: 16081202 [TBL] [Abstract][Full Text] [Related]
3. Comparison of methods of bag and mask ventilation for neonatal resuscitation. Finer NN; Rich W; Craft A; Henderson C Resuscitation; 2001 Jun; 49(3):299-305. PubMed ID: 11719125 [TBL] [Abstract][Full Text] [Related]
4. Can EMS Providers Provide Appropriate Tidal Volumes in a Simulated Adult-sized Patient with a Pediatric-sized Bag-Valve-Mask? Siegler J; Kroll M; Wojcik S; Moy HP Prehosp Emerg Care; 2017; 21(1):74-78. PubMed ID: 27690714 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of mask-bag ventilation in resuscitation of infants. Kanter RK Am J Dis Child; 1987 Jul; 141(7):761-3. PubMed ID: 3591766 [TBL] [Abstract][Full Text] [Related]
6. Decreasing peak flow rate with a new bag-valve-mask device: effects on respiratory mechanics, and gas distribution in a bench model of an unprotected airway. Wagner-Berger HG; Wenzel V; Stallinger A; Voelckel WG; Rheinberger K; Stadlbauer KH; Augenstein S; Dörges V; Lindner KH; Hörmann C Resuscitation; 2003 May; 57(2):193-9. PubMed ID: 12745188 [TBL] [Abstract][Full Text] [Related]
7. Comparison of ventilation performance: standard resuscitation bag and the resuscitation bag controller. Terndrup TE; Cherry RA; McCabe JB J Emerg Med; 1990; 8(2):121-5. PubMed ID: 2362111 [TBL] [Abstract][Full Text] [Related]
8. Neonatal mannequin comparison of the Upright self-inflating bag and snap-fit mask versus standard resuscitators and masks: leak, applied load and tidal volumes. Rafferty AR; Johnson L; Davis PG; Dawson JA; Thio M; Owen LS Arch Dis Child Fetal Neonatal Ed; 2018 Nov; 103(6):F562-F566. PubMed ID: 29191811 [TBL] [Abstract][Full Text] [Related]
9. Comparison of different airway management strategies to ventilate apneic, nonpreoxygenated patients. Dörges V; Wenzel V; Knacke P; Gerlach K Crit Care Med; 2003 Mar; 31(3):800-4. PubMed ID: 12626987 [TBL] [Abstract][Full Text] [Related]
10. [Emergency airway management-- comparison of various strategies in an unsecured airway]. Dörges V; Ocker H; Neubert E; Schumann T; Wenzel V Wien Klin Wochenschr; 2001 Mar; 113(5-6):186-93. PubMed ID: 11293948 [TBL] [Abstract][Full Text] [Related]
11. Preliminary evaluation of a prototype tube-valve-mask ventilator for emergency artificial ventilation. Giffen PR; Hope CE Ann Emerg Med; 1991 Mar; 20(3):262-6. PubMed ID: 1899984 [TBL] [Abstract][Full Text] [Related]
12. Comparison of 1- versus 2-person bag-valve-mask techniques for manikin ventilation of infants and children. Davidovic L; LaCovey D; Pitetti RD Ann Emerg Med; 2005 Jul; 46(1):37-42. PubMed ID: 15988424 [TBL] [Abstract][Full Text] [Related]
13. Comparison of Efficacy of Pressure Controlled vs. Traditional Manual Mask Ventilation for Newborn Resuscitation - A Simulation-Based Pilot Randomized Control Trial. Kalane S; Upadhye V; Mulay AV; Prayag AP Indian J Pediatr; 2024 Oct; 91(10):1008-1013. PubMed ID: 38012507 [TBL] [Abstract][Full Text] [Related]
14. Pediatric Respiratory Therapists Lack a Standard Mental Model for Managing the Patient Who Is Difficult to Ventilate: A Video Review. Perretta JS; Salamone C; King D; Mann S; Duval-Arnould J; Hunt EA Respir Care; 2019 Jul; 64(7):801-808. PubMed ID: 30890631 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of a Multimodal Resuscitation Program and Comparison of Mouth-to-Mouth and Bag-Mask Ventilation by Relatives of Children With Chronic Diseases. Michel J; Hofbeck M; Neunhoeffer F; Müller M; Heimberg E Pediatr Crit Care Med; 2020 Feb; 21(2):e114-e120. PubMed ID: 31834244 [TBL] [Abstract][Full Text] [Related]
16. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin? Tracy MB; Priyadarshi A; Goel D; Lowe K; Huvanandana J; Hinder M Arch Dis Child Fetal Neonatal Ed; 2018 May; 103(3):F271-F276. PubMed ID: 28802261 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of Simulated Ventilation Techniques With the Upright and Conventional Self-Inflating Neonatal Resuscitators. Narayanan I; Mendhi M; Bansil P; Coffey PS Respir Care; 2017 Nov; 62(11):1428-1436. PubMed ID: 28830928 [TBL] [Abstract][Full Text] [Related]
19. A comparison of the effectiveness of pre-hospital bag-valve-mask ventilation performed by Irish emergency medical technicians and anaesthetists working in a tertiary referral teaching hospital. Walsh K; Loveday K; O'Rathaille M Ir Med J; 2003 Mar; 96(3):77-9. PubMed ID: 12722783 [TBL] [Abstract][Full Text] [Related]
20. A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway. Zecha-Stallinger A; Wenzel V; Wagner-Berger HG; von Goedecke A; Lindner KH; Hörmann C Resuscitation; 2004 Apr; 61(1):69-74. PubMed ID: 15081184 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]