  • 1. High-resolution monitoring of the gastrointestinal transit of a magnetically marked capsule.
    Weitschies W; Kötitz R; Cordini D; Trahms L
    J Pharm Sci; 1997 Nov; 86(11):1218-22. PubMed ID: 9383729
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Magnetic marker monitoring of esophageal, gastric and duodenal transit of non-disintegrating capsules.
    Weitschies W; Cardini D; Karaus M; Trahms L; Semmler W
    Pharmazie; 1999 Jun; 54(6):426-30. PubMed ID: 10399189
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic Marker Monitoring: An application of biomagnetic measurement instrumentation and principles for the determination of the gastrointestinal behavior of magnetically marked solid dosage forms.
    Weitschies W; Kosch O; Mönnikes H; Trahms L
    Adv Drug Deliv Rev; 2005 Jun; 57(8):1210-22. PubMed ID: 15935870
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of a biomagnetic measurement system (BMS) to the evaluation of gastrointestinal transit of intestinal pressure-controlled colon delivery capsules (PCDCs) in human subjects.
    Hu Z; Mawatari S; Shibata N; Takada K; Yoshikawa H; Arakawa A; Yosida Y
    Pharm Res; 2000 Feb; 17(2):160-7. PubMed ID: 10751030
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic markers as a noninvasive tool to monitor gastrointestinal transit.
    Weitschies W; Wedemeyer J; Stehr R; Trahms L
    IEEE Trans Biomed Eng; 1994 Feb; 41(2):192-5. PubMed ID: 8026852
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Oesophageal transport of solid dosage forms depends on body position, swallowing volume and pharyngeal propulsion velocity.
    Osmanoglou E; Van Der Voort IR; Fach K; Kosch O; Bach D; Hartmann V; Strenzke A; Weitschies W; Wiedenmann B; Trahms L; Mönnikes H
    Neurogastroenterol Motil; 2004 Oct; 16(5):547-56. PubMed ID: 15500511
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetic marker monitoring: high resolution real-time tracking of oral solid dosage forms in the gastrointestinal tract.
    Weitschies W; Blume H; Mönnikes H
    Eur J Pharm Biopharm; 2010 Jan; 74(1):93-101. PubMed ID: 19619649
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Investigation of gastrointestinal transport by magnetic marker localization.
    Kosch O; Osmanoglou E; Hartman V; Strenzke A; Weitschies W; Wiedenmann B; Mönnikes H; Trahms L
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():506-9. PubMed ID: 12465220
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Estimation of the gastric residence time of magnetic dosage forms using the Heidelberg capsule.
    Groning R; Berntgen M
    Pharmazie; 1996 May; 51(5):328-31. PubMed ID: 8710954
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomagnetic 3-dimensional spatial and temporal characterization of electrical activity of human stomach.
    Allescher HD; Abraham-Fuchs K; Dunkel RE; Classen M
    Dig Dis Sci; 1998 Apr; 43(4):683-93. PubMed ID: 9558020
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A portable method for assessing gastrointestinal motility by simultaneously measuring transit time and contraction frequency.
    Li H; Yan G
    J Med Eng Technol; 2008; 32(6):448-55. PubMed ID: 19005962
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The sono-capsule: a new method for measuring gastrointestinal motility].
    Amend M; Greiner L
    Ultraschall Med; 1996 Dec; 17(6):274-6. PubMed ID: 9082552
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel marker design for magnetic marker monitoring in the human gastrointestinal tract.
    Biller S; Baumgarten D; Haueisen J
    IEEE Trans Biomed Eng; 2011 Dec; 58(12):3368-75. PubMed ID: 21968707
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detection of bacteria in suspension by using a superconducting quantum interference device.
    Grossman HL; Myers WR; Vreeland VJ; Bruehl R; Alper MD; Bertozzi CR; Clarke J
    Proc Natl Acad Sci U S A; 2004 Jan; 101(1):129-34. PubMed ID: 14688406
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gastrointestinal transit and disintegration of enteric coated magnetic tablets assessed by ac biosusceptometry.
    Corá LA; Romeiro FG; Américo MF; Oliveira RB; Baffa O; Stelzer M; Miranda JR
    Eur J Pharm Sci; 2006 Jan; 27(1):1-8. PubMed ID: 16188432
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An integrative software package for gastrointestinal biomagnetic data acquisition and analysis using SQUID magnetometers.
    Irimia A; Cheng LK; Buist ML; Pullan AJ; Bradshaw LA
    Comput Methods Programs Biomed; 2006 Aug; 83(2):83-94. PubMed ID: 16857291
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomagnetic detection of gastric electrical activity in normal and vagotomized rabbits.
    Bradshaw LA; Myers AG; Redmond A; Wikswo JP; Richards WO
    Neurogastroenterol Motil; 2003 Oct; 15(5):475-82. PubMed ID: 14507349
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Magnetic marker monitoring of disintegrating capsules.
    Weitschies W; Karaus M; Cordini D; Trahms L; Breitkreutz J; Semmler W
    Eur J Pharm Sci; 2001 Jul; 13(4):411-6. PubMed ID: 11408156
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microtesla MRI with a superconducting quantum interference device.
    McDermott R; Lee S; ten Haken B; Trabesinger AH; Pines A; Clarke J
    Proc Natl Acad Sci U S A; 2004 May; 101(21):7857-61. PubMed ID: 15141077
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Controlled navigation of endoscopic capsules: concept and preliminary experimental investigations.
    Carpi F; Galbiati S; Carpi A
    IEEE Trans Biomed Eng; 2007 Nov; 54(11):2028-36. PubMed ID: 18018698
    [TBL] [Abstract][Full Text] [Related]  