These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
110 related articles for article (PubMed ID: 9389867)
1. Laboratory evaluation of the I-NOvent nitric oxide delivery device. Young JD; Roberts M; Gale LB Br J Anaesth; 1997 Sep; 79(3):398-401. PubMed ID: 9389867 [TBL] [Abstract][Full Text] [Related]
3. Delivery of inhaled nitric oxide using the Ohmeda INOvent Delivery System. Kirmse M; Hess D; Fujino Y; Kacmarek RM; Hurford WE Chest; 1998 Jun; 113(6):1650-7. PubMed ID: 9631807 [TBL] [Abstract][Full Text] [Related]
4. Inaccuracies of nitric oxide delivery systems during adult mechanical ventilation. Imanaka H; Hess D; Kirmse M; Bigatello LM; Kacmarek RM; Steudel W; Hurford WE Anesthesiology; 1997 Mar; 86(3):676-88. PubMed ID: 9066335 [TBL] [Abstract][Full Text] [Related]
5. Performance of proportional and continuous nitric oxide delivery systems during pressure- and volume-controlled ventilation. Hiesmayr MJ; Neugebauer T; Lassnigg A; Steltzer H; Haider W; Gilly H Br J Anaesth; 1998 Oct; 81(4):544-52. PubMed ID: 9924230 [TBL] [Abstract][Full Text] [Related]
6. Flow-proportional administration of nitric oxide with a new delivery system: inspiratory nitric oxide concentration fluctuation during different flow conditions. Sydow M; Bristow F; Zinserling J; Allen SJ Chest; 1997 Aug; 112(2):496-504. PubMed ID: 9266890 [TBL] [Abstract][Full Text] [Related]
7. A delivery system for inhalation of nitric oxide evaluated with chemiluminescence, electrochemical fuel cells, and capnography. Lindberg L; Rydgren G; Larsson A; Olsson SG; Nordström L Crit Care Med; 1997 Jan; 25(1):190-6. PubMed ID: 8989197 [TBL] [Abstract][Full Text] [Related]
8. Variation of nitric oxide concentration during inspiration. Sydow M; Bristow F; Zinserling J; Allen SJ Crit Care Med; 1997 Feb; 25(2):365-71. PubMed ID: 9034278 [TBL] [Abstract][Full Text] [Related]
9. A bench study of inhaled nitric oxide delivery during high frequency percussive ventilation. Branson RD; Griebel J; Rodriquez D Pediatr Pulmonol; 2018 Mar; 53(3):337-341. PubMed ID: 29314741 [TBL] [Abstract][Full Text] [Related]
10. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Bachiller PR; McDonough JM; Feldman JM Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850 [TBL] [Abstract][Full Text] [Related]
11. Distribution of inhaled nitric oxide during sequential and continuous administration into the inspiratory limb of the ventilator. Mourgeon E; Gallart L; Rao GS; Lu Q; Law-Koune JD; Puybasset L; Coriat P; Rouby JJ Intensive Care Med; 1997 Aug; 23(8):849-58. PubMed ID: 9310802 [TBL] [Abstract][Full Text] [Related]
13. A portable nitric oxide scavenging system designed for use on neonatal transport. Dhillon JS; Kronick JB; Singh NC; Johnson CC Crit Care Med; 1996 Jun; 24(6):1068-71. PubMed ID: 8681575 [TBL] [Abstract][Full Text] [Related]
15. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode. Tung A; Drum ML; Morgan S J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723 [TBL] [Abstract][Full Text] [Related]
16. Ideation and assessment of a nitric oxide delivery system for spontaneously breathing subjects. Gianni S; Morais CCA; Larson G; Pinciroli R; Carroll R; Yu B; Zapol WM; Berra L Nitric Oxide; 2020 Nov; 104-105():29-35. PubMed ID: 32835810 [TBL] [Abstract][Full Text] [Related]
17. Delivery and monitoring of inhaled nitric oxide in patients with pulmonary hypertension. Wessel DL; Adatia I; Thompson JE; Hickey PR Crit Care Med; 1994 Jun; 22(6):930-8. PubMed ID: 8205825 [TBL] [Abstract][Full Text] [Related]
18. Behavior of nitric oxide infused at constant flow rates directly into a breathing circuit during controlled mechanical ventilation. Skimming JW; Blanch PB; Banner MJ Crit Care Med; 1997 Aug; 25(8):1410-6. PubMed ID: 9267958 [TBL] [Abstract][Full Text] [Related]
19. Effect of Nitric Oxide Delivery Device on Tidal Volume Accuracy During Mechanical Ventilation at Small Tidal Volumes. Ranallo CD; Thurman TL; Holt SJ; Frank-Pearce SG; Anderson MP; Heulitt MJ Respir Care; 2020 Nov; 65(11):1641-1647. PubMed ID: 32518087 [TBL] [Abstract][Full Text] [Related]