These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 9393921)

  • 1. Synthetic osteochondral replacement of the femoral articular surface.
    Oka M; Chang YS; Nakamura T; Ushio K; Toguchida J; Gu HO
    J Bone Joint Surg Br; 1997 Nov; 79(6):1003-7. PubMed ID: 9393921
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of artificial articular cartilage.
    Oka M; Ushio K; Kumar P; Ikeuchi K; Hyon SH; Nakamura T; Fujita H
    Proc Inst Mech Eng H; 2000; 214(1):59-68. PubMed ID: 10718051
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Partial hemiarthroplasty for the treatment of osteonecrosis of the femoral head. An experimental study in the dog.
    Ushio K; Oka M; Hyon SH; Yura S; Toguchida J; Nakamura T
    J Bone Joint Surg Br; 2003 Aug; 85(6):922-30. PubMed ID: 12931820
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Significance of interstitial bone ingrowth under load-bearing conditions: a comparison between solid and porous implant materials.
    Chang YS; Oka M; Kobayashi M; Gu HO; Li ZL; Nakamura T; Ikada Y
    Biomaterials; 1996 Jun; 17(11):1141-8. PubMed ID: 8718976
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bone formation and remodeling around implanted materials under load-bearing conditions.
    Chang YS; Oka M; Kobayashi M; Gu HO; Li ZL; Kitsugi T; Nakamura T
    Clin Mater; 1994; 17(4):181-7. PubMed ID: 10172487
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of synthetic osteochondral implants.
    Cook JL; Kuroki K; Bozynski CC; Stoker AM; Pfeiffer FM; Cook CR
    J Knee Surg; 2014 Aug; 27(4):295-302. PubMed ID: 24281985
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of various structure treatments on histological fixation of titanium implants.
    Chang YS; Gu HO; Kobayashi M; Oka M
    J Arthroplasty; 1998 Oct; 13(7):816-25. PubMed ID: 9802671
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Osseointegration and mechanical stability of pyrocarbon and titanium hand implants in a load-bearing in vivo model for small joint arthroplasty.
    Daecke W; Veyel K; Wieloch P; Jung M; Lorenz H; Martini AK
    J Hand Surg Am; 2006 Jan; 31(1):90-7. PubMed ID: 16443111
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A finite element model of the human knee joint for the study of tibio-femoral contact.
    Donahue TL; Hull ML; Rashid MM; Jacobs CR
    J Biomech Eng; 2002 Jun; 124(3):273-80. PubMed ID: 12071261
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Histologic comparison of tibial articular surfaces against rigid materials and artificial articular cartilage.
    Chang YS; Oka M; Gu HO; Kobayashi M; Toguchida J; Nakamura T; Hayami T
    J Biomed Mater Res; 1997 Oct; 37(1):51-9. PubMed ID: 9335349
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanics and repair of articular cartilage.
    Oka M
    J Orthop Sci; 2001; 6(5):448-56. PubMed ID: 11845357
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Synthetic PVA Osteochondral Implants for the Knee Joint: Mechanical Characteristics During Simulated Gait.
    Chen T; Brial C; McCarthy M; Warren RF; Maher SA
    Am J Sports Med; 2021 Sep; 49(11):2933-2941. PubMed ID: 34347534
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of an artificial articular cartilage.
    Oka M; Noguchi T; Kumar P; Ikeuchi K; Yamamuro T; Hyon SH; Ikada Y
    Clin Mater; 1990; 6(4):361-81. PubMed ID: 10171540
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of tibial lengthening using the Ilizarov method on the cartilage and the menisci of the knee joint.
    Fink B; Schwinger G; Singer J; Sager M; Wilke C; Braunstein S
    J Orthop Res; 2001 Jul; 19(4):665-70. PubMed ID: 11518277
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Composite device for attachment of polyvinyl alcohol-hydrogel to underlying bone.
    Kobayashi M; Oka M
    Artif Organs; 2004 Aug; 28(8):734-8. PubMed ID: 15270955
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions.
    Søballe K; Hansen ES; B-Rasmussen H; Jørgensen PH; Bünger C
    J Orthop Res; 1992 Mar; 10(2):285-99. PubMed ID: 1311039
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The mechanical-chemical attachment between the artificial articular cartilage (PVA-hydrogel) and metal substrate (or underlying bone).
    Gu ZQ; Xiao JM; Lou SQ
    Biomed Mater Eng; 1999; 9(5-6):347-51. PubMed ID: 10822490
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fixation of a double-coated titanium-hydroxyapatite focal knee resurfacing implant: a 12-month study in sheep.
    Martinez-Carranza N; Berg HE; Lagerstedt AS; Nurmi-Sandh H; Schupbach P; Ryd L
    Osteoarthritis Cartilage; 2014 Jun; 22(6):836-44. PubMed ID: 24726379
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of flexibility of the femoral stem on bone-remodeling and fixation of the stem in a canine total hip arthroplasty model without cement.
    Harvey EJ; Bobyn JD; Tanzer M; Stackpool GJ; Krygier JJ; Hacking SA
    J Bone Joint Surg Am; 1999 Jan; 81(1):93-107. PubMed ID: 9973059
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Enhancing Soft-tissue Reattachment with Artificial Mesh in Joint Endoprosthetic Reconstruction for Bone Tumors].
    Lin JS; Chen R; Yan W; Chen DD
    Zhonghua Zhong Liu Za Zhi; 2017 Jul; 39(7):540-544. PubMed ID: 28728303
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.