These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 9394397)

  • 21. A standard for absorbed dose rate to water in a 60Co field using a graphite calorimeter at the National Metrology Institute of Japan.
    Morishita Y; Kato M; Takata N; Kurosawa T; Tanaka T; Saito N
    Radiat Prot Dosimetry; 2013; 154(3):331-9. PubMed ID: 22951998
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Clinic based transfer of the N(D,W)(60Co) calibration coefficient using a linear accelerator.
    Abdel-Rahman W; Evans MD; Serré L; McCaffrey JP; Podgorsak EB; Seuntjens JP
    Med Phys; 2009 Mar; 36(3):929-38. PubMed ID: 19378753
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Absorbed-dose calibrations in high-energy photon beams at the National Physical Laboratory: conversion procedure.
    Burns JE
    Phys Med Biol; 1994 Oct; 39(10):1555-75. PubMed ID: 15551531
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of two methods of therapy level calibration at 60Co gamma beams.
    Bjerke H; Järvinen H; Grimbergen TW; Grindborg JE; Chauvenet B; Czap L; Ennow K; Moretti C; Rocha P
    Phys Med Biol; 1998 Oct; 43(10):2729-40. PubMed ID: 9814513
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A comparison of Australian and Canadian calibration coefficients for air kerma and absorbed dose to water for 60Co gamma radiation.
    Shortt KR; Huntley RB; Kotler LH; Boas JF; Webb DV
    Australas Phys Eng Sci Med; 2006 Jun; 29(2):206-15. PubMed ID: 16845927
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A small-body portable graphite calorimeter for dosimetry in low-energy clinical proton beams.
    Palmans H; Thomas R; Simon M; Duane S; Kacperek A; DuSautoy A; Verhaegen F
    Phys Med Biol; 2004 Aug; 49(16):3737-49. PubMed ID: 15446802
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Aerrow: A probe-format graphite calorimeter for absolute dosimetry of high-energy photon beams in the clinical environment.
    Renaud J; Sarfehnia A; Bancheri J; Seuntjens J
    Med Phys; 2018 Jan; 45(1):414-428. PubMed ID: 29131344
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Ferrous sulphate dosimeter for control of ionization chamber dosimetry of electron and 60Co gamma beams.
    Mattsson LO; Johansson KA; Svensson H
    Acta Radiol Oncol; 1982; 21(2):139-44. PubMed ID: 6289615
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Graphite calorimeter in water phantom and calibration of ionization chambers in dose to water for 60Co gamma radiation.
    Sundara Rao IS; Naik SB
    Med Phys; 1980; 7(3):196-201. PubMed ID: 7393144
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Absorbed dose beam quality correction factors kappaQ for the NE2571 chamber in a 5 MV and a 10 MV photon beam.
    Palmans H; Mondelaers W; Thierens H
    Phys Med Biol; 1999 Mar; 44(3):647-63. PubMed ID: 10211800
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Perturbation corrections for flat and thimble-type cylindrical standard ionization chambers for 60Co gamma rays: Monte Carlo calculations.
    Ferreira IH; Bridier A; de Almeida CE; Marre D; Chavaudra J
    Phys Med Biol; 1998 Oct; 43(10):2721-7. PubMed ID: 9814512
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development of a portable graphite calorimeter for radiation dosimetry.
    Sakama M; Kanai T; Fukumura A
    Igaku Butsuri; 2008; 28(1):1-14. PubMed ID: 21976250
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Phenomenological dose model for therapeutic photon beams: basic concepts and definitions.
    Nizin PS
    Med Phys; 1999 Sep; 26(9):1893-900. PubMed ID: 10505878
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Clinical reference dosimetry: comparison between AAPM TG-21 and TG-51 protocols.
    Ding GX; Cygler JE; Kwok CB
    Med Phys; 2000 Jun; 27(6):1217-25. PubMed ID: 10902550
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Experimental determination of the beam quality dependence factors, kQ, for ionization chambers used in photon and electron dosimetry.
    Guerra AS; Laitano RF; Pimpinella M
    Phys Med Biol; 1995 Jul; 40(7):1177-90. PubMed ID: 7568376
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A new approach to electron-beam reference dosimetry.
    Rogers DW
    Med Phys; 1998 Mar; 25(3):310-20. PubMed ID: 9547498
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A comparison between calculated and experimental kQ photon beam quality correction factors.
    Andreo P
    Phys Med Biol; 2000 Sep; 45(9):L25-38. PubMed ID: 11008946
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The Fricke dosimeter as an absorbed dose to water primary standard for Ir-192 brachytherapy.
    El Gamal I; Cojocaru C; Mainegra-Hing E; McEwen M
    Phys Med Biol; 2015 Jun; 60(11):4481-95. PubMed ID: 25988983
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Measurement of ionization chamber absorbed dose k(Q) factors in megavoltage photon beams.
    McEwen MR
    Med Phys; 2010 May; 37(5):2179-93. PubMed ID: 20527552
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 60Co radiation.
    Lye JE; Butler DJ; Franich RD; Harty PD; Oliver CP; Ramanathan G; Webb DV; Wright T
    Radiat Prot Dosimetry; 2013 Jun; 155(1):100-9. PubMed ID: 23152147
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.