These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
100 related articles for article (PubMed ID: 9409417)
1. Intraoperative monitoring of jugular bulb oxygen saturation in patients with moyamoya disease. Oshima H; Katayama Y; Hirayama T; Koshinaga M; Yamamoto T Clin Neurol Neurosurg; 1997 Oct; 99 Suppl 2():S106-9. PubMed ID: 9409417 [TBL] [Abstract][Full Text] [Related]
2. Intracerebral steal phenomenon associated with global hyperemia in moyamoya disease during revascularization surgery. Oshima H; Katayama Y; Hirayama T J Neurosurg; 2000 Jun; 92(6):949-54. PubMed ID: 10839254 [TBL] [Abstract][Full Text] [Related]
3. Continuous monitoring of jugular bulb oxygen saturation as a measure of the shunt flow of cerebral arteriovenous malformations. Katayama Y; Tsubokawa T; Hirayama T; Himi K J Neurosurg; 1994 May; 80(5):826-33. PubMed ID: 8169621 [TBL] [Abstract][Full Text] [Related]
4. Analysis of abnormal jugular bulb oxygen saturation data in patients with severe head injury. de Deyne C; Vandekerckhove T; Decruyenaere J; Colardyn F Acta Neurochir (Wien); 1996; 138(12):1409-15. PubMed ID: 9030347 [TBL] [Abstract][Full Text] [Related]
5. Hypercapnia prevents jugular bulb desaturation during rewarming from hypothermic cardiopulmonary bypass. Hänel F; von Knobelsdorff G; Werner C; Schulte am Esch J Anesthesiology; 1998 Jul; 89(1):19-23. PubMed ID: 9667289 [TBL] [Abstract][Full Text] [Related]
6. [A case of hyperemia during arteriovenous malformation surgery controlled with beta-blocker and jugular bulb oxygen saturation (SjO2) monitoring]. Kimiwada T; Kamii H; Tominaga T; Kato M Masui; 2003 Oct; 52(10):1074-8. PubMed ID: 14598670 [TBL] [Abstract][Full Text] [Related]
7. [Changes in oxygen saturation in the jugular bulb during cardiac surgery]. Fita G; Gomar C; Rovira I; Basora MC Rev Esp Anestesiol Reanim; 1999 Dec; 46(10):438-44. PubMed ID: 10670265 [TBL] [Abstract][Full Text] [Related]
8. [Cerebral oximetry by infrared spectroscopy in comparison with continuous measurement of oxygen saturation of the jugular vein bulb in interventions of the internal carotid artery]. Schindler E; Zickmann B; Müller M; Boldt J; Kroll J; Hempelmann G Vasa; 1995; 24(2):168-75. PubMed ID: 7793150 [TBL] [Abstract][Full Text] [Related]
9. [Cerebral oxygen desaturation during rewarming in retrograde cerebral perfusion with total circulatory arrest]. Saito S; Aomi S; Takazawa A; Yamaki F; Sakahashi H; Nomura M; Kondo I; Nagasawa C; Hashimoto A; Koyanagi H Nihon Kyobu Geka Gakkai Zasshi; 1996 Dec; 44(12):2138-45. PubMed ID: 8990886 [TBL] [Abstract][Full Text] [Related]
10. Correlation of jugular venous oxygen saturation to spontaneous fluctuations of cerebral perfusion pressure in patients with severe head injury. Murr R; Schürer L Neurol Res; 1995 Oct; 17(5):329-33. PubMed ID: 8584122 [TBL] [Abstract][Full Text] [Related]
11. [Continuous fiberoptic monitoring of oxygen saturation in cerebral veins in severe craniocerebral trauma--experiences and results]. Murr R; Schürer L; Polasek J Anasthesiol Intensivmed Notfallmed Schmerzther; 1996 Feb; 31(1):29-36. PubMed ID: 8868530 [TBL] [Abstract][Full Text] [Related]
12. The Correlation of Two Cerebral Saturation Monitors With Jugular Bulb Oxygen Saturation in Children Undergoing Cardiopulmonary Bypass for Congenital Heart Surgery. Naguib AN; Winch PD; Sebastian R; Gomez D; Guzman L; Rice J; Tumin D; Galantowicz M; Tobias JD J Intensive Care Med; 2017 Dec; 32(10):603-608. PubMed ID: 27530512 [TBL] [Abstract][Full Text] [Related]
13. Jugular bulb oximetry: review on a cerebral monitoring technique. De Deyne C; Van Aken J; Decruyenaere J; Struys M; Colardyn F Acta Anaesthesiol Belg; 1998; 49(1):21-31. PubMed ID: 9627734 [TBL] [Abstract][Full Text] [Related]
14. Analysis of factors related to jugular venous oxygen saturation during cardiopulmonary bypass. Yoshitake A; Goto T; Baba T; Shibata Y J Cardiothorac Vasc Anesth; 1999 Apr; 13(2):160-4. PubMed ID: 10230949 [TBL] [Abstract][Full Text] [Related]
16. Arterial and venous contributions to near-infrared cerebral oximetry. Watzman HM; Kurth CD; Montenegro LM; Rome J; Steven JM; Nicolson SC Anesthesiology; 2000 Oct; 93(4):947-53. PubMed ID: 11020744 [TBL] [Abstract][Full Text] [Related]
17. Limits of intermittent jugular bulb oxygen saturation monitoring in the management of severe head trauma patients. Latronico N; Beindorf AE; Rasulo FA; Febbrari P; Stefini R; Cornali C; Candiani A Neurosurgery; 2000 May; 46(5):1131-8; discussion 1138-9. PubMed ID: 10807245 [TBL] [Abstract][Full Text] [Related]
18. Monitoring of cerebral oxygen metabolism in the jugular bulb: reliability of unilateral measurements in severe head injury. Metz C; Holzschuh M; Bein T; Woertgen C; Rothoerl R; Kallenbach B; Taeger K; Brawanski A J Cereb Blood Flow Metab; 1998 Mar; 18(3):332-43. PubMed ID: 9498850 [TBL] [Abstract][Full Text] [Related]
19. Accuracy of continuous jugular bulb oximetry in the intensive care unit. Coplin WM; O'Keefe GE; Grady MS; Grant GA; March KS; Winn HR; Lam AM Neurosurgery; 1998 Mar; 42(3):533-9; discussion 539-40. PubMed ID: 9526988 [TBL] [Abstract][Full Text] [Related]
20. Continuous monitoring of jugular bulb oxygen saturation and the effect of drugs acting on cerebral metabolism. Bullock R; Stewart L; Rafferty C; Teasdale GM Acta Neurochir Suppl (Wien); 1993; 59():113-8. PubMed ID: 7906076 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]