These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
130 related articles for article (PubMed ID: 9417620)
41. Comparative evaluation of ultrasound scanner accuracy in distance measurement. Branca FP; Sciuto SA; Scorza A Rev Sci Instrum; 2012 Oct; 83(10):105103. PubMed ID: 23126800 [TBL] [Abstract][Full Text] [Related]
42. Ultrasound and ultrasound biomicroscopy as a diagnostic tool. DeschĂȘnes J; Mansour M; Rudzinski M Dev Ophthalmol; 1999; 31():14-21. PubMed ID: 10641196 [No Abstract] [Full Text] [Related]
43. [Tomodensitometric study of the normal and the pathological eyeball]. Bronner A; Kosmann P; Risse JF; Ammerich H; Wackenheim A Bull Soc Ophtalmol Fr; 1977; 77(11-12):957-61. PubMed ID: 617062 [No Abstract] [Full Text] [Related]
44. [Optic biometry in intraocular lense calculation for cataract surgery. Comparison with usual methods]. Siahmed K; Muraine M; Brasseur G J Fr Ophtalmol; 2001 Nov; 24(9):922-6. PubMed ID: 11912834 [TBL] [Abstract][Full Text] [Related]
45. Sonography of the eye. Bedi DG; Gombos DS; Ng CS; Singh S AJR Am J Roentgenol; 2006 Oct; 187(4):1061-72. PubMed ID: 16985158 [TBL] [Abstract][Full Text] [Related]
46. AAPM/RSNA physics tutorial for residents. Topics in US: B-mode US: basic concepts and new technology. Hangiandreou NJ Radiographics; 2003; 23(4):1019-33. PubMed ID: 12853678 [TBL] [Abstract][Full Text] [Related]
47. Ultrasound and its various modes in use-part I. Keil OR Med Instrum; 1982; 16(1):27-30. PubMed ID: 7062866 [TBL] [Abstract][Full Text] [Related]
48. Photoacoustic tomography imaging system based on digital B-mode ultrasound diagnosis equipment. Guo H; Yang S Rev Sci Instrum; 2009 Jan; 80(1):014903. PubMed ID: 19191456 [TBL] [Abstract][Full Text] [Related]
49. Introduction to diagnostic ophthalmic ultrasound for nurses in ophthalmology. Mrochuk J J Ophthalmic Nurs Technol; 1990; 9(6):234-9. PubMed ID: 2254943 [TBL] [Abstract][Full Text] [Related]
51. [Simple extension of an ultrasound B image device to a cw duplex scanner for carotid artery studies]. Widder B Ultraschall Med; 1985 Oct; 6(5):286-90. PubMed ID: 2934815 [TBL] [Abstract][Full Text] [Related]
52. Telemedical diagnosis of anterior segment eye diseases: validation of digital slit-lamp still images. Kumar S; Yogesan K; Constable IJ Eye (Lond); 2009 Mar; 23(3):652-60. PubMed ID: 18274557 [TBL] [Abstract][Full Text] [Related]
53. Globe axial length data in children using immersion A-scan ultrasound. Trivedi RH; Wilson ME J Cataract Refract Surg; 2021 Nov; 47(11):1481-1482. PubMed ID: 33298781 [No Abstract] [Full Text] [Related]
54. New developments in equipment. Blackwell R Clin Obstet Gynaecol; 1983 Dec; 10(3):371-94. PubMed ID: 6653025 [TBL] [Abstract][Full Text] [Related]
55. Agreement and reproducibility of contact and immersion techniques for axial length measurement and intraocular lens power calculation. Kitthaweesin K; Mungsing W J Med Assoc Thai; 2009 Aug; 92(8):1046-9. PubMed ID: 19694329 [TBL] [Abstract][Full Text] [Related]