172 related articles for article (PubMed ID: 9418620)
1. The effect of tibial stem design on component micromotion in knee arthroplasty.
Stern SH; Wills RD; Gilbert JL
Clin Orthop Relat Res; 1997 Dec; (345):44-52. PubMed ID: 9418620
[TBL] [Abstract][Full Text] [Related]
2. Tibial component fixation with cement: full- versus surface-cementation techniques.
Peters CL; Craig MA; Mohr RA; Bachus KN
Clin Orthop Relat Res; 2003 Apr; (409):158-68. PubMed ID: 12671498
[TBL] [Abstract][Full Text] [Related]
3. Analysis of bone-prosthesis interface micromotion for cementless tibial prosthesis fixation and the influence of loading conditions.
Chong DY; Hansen UN; Amis AA
J Biomech; 2010 Apr; 43(6):1074-80. PubMed ID: 20189576
[TBL] [Abstract][Full Text] [Related]
4. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
[TBL] [Abstract][Full Text] [Related]
5. Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation.
Luring C; Perlick L; Trepte C; Linhardt O; Perlick C; Plitz W; Grifka J
Arch Orthop Trauma Surg; 2006 Jan; 126(1):45-8. PubMed ID: 16333631
[TBL] [Abstract][Full Text] [Related]
6. The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement.
Chong DY; Hansen UN; van der Venne R; Verdonschot N; Amis AA
J Biomech; 2011 Mar; 44(5):948-54. PubMed ID: 21236431
[TBL] [Abstract][Full Text] [Related]
7. The role of fixation and bone quality on the mechanical stability of tibial knee components.
Lee RW; Volz RG; Sheridan DC
Clin Orthop Relat Res; 1991 Dec; (273):177-83. PubMed ID: 1959268
[TBL] [Abstract][Full Text] [Related]
8. Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy.
Yamazaki T; Watanabe T; Nakajima Y; Sugamoto K; Tomita T; Maeda D; Sahara W; Yoshikawa H; Tamura S
Eur J Radiol; 2005 Jan; 53(1):84-9. PubMed ID: 15607857
[TBL] [Abstract][Full Text] [Related]
9. Addition of a short central extension to surface cemented tibial trays in primary TKA: an in vitro study of the effect on initial fixation stability and its relationship to supporting bone density.
Pérez-Blanca A; Prado M; Ezquerro F; Montañéz E; Espejo A
Clin Biomech (Bristol, Avon); 2008 May; 23(4):483-92. PubMed ID: 18171597
[TBL] [Abstract][Full Text] [Related]
10. The role of the design of tibial components and stems in knee replacement.
Scott CE; Biant LC
J Bone Joint Surg Br; 2012 Aug; 94(8):1009-15. PubMed ID: 22844039
[TBL] [Abstract][Full Text] [Related]
11. Fixation response of two cementless tibial implants under static and fatigue compression loading.
Dammak M; Shirazi-Adl A; Zukor DJ
Technol Health Care; 2003; 11(4):245-52. PubMed ID: 14600335
[TBL] [Abstract][Full Text] [Related]
12. Cementless fixation of radial head implants is affected by implant stem geometry: an in vitro study.
Ferreira LM; Stacpoole RA; Johnson JA; King GJ
Clin Biomech (Bristol, Avon); 2010 Jun; 25(5):422-6. PubMed ID: 20303631
[TBL] [Abstract][Full Text] [Related]
13. Strain shielding in proximal tibia of stemmed knee prosthesis: experimental study.
Completo A; Fonseca F; Simões JA
J Biomech; 2008; 41(3):560-6. PubMed ID: 18036530
[TBL] [Abstract][Full Text] [Related]
14. Micromotion of cementless tibial baseplates under physiological loading conditions.
Bhimji S; Meneghini RM
J Arthroplasty; 2012 Apr; 27(4):648-54. PubMed ID: 21831575
[TBL] [Abstract][Full Text] [Related]
15. The effect of surface finish and of vertical ribs on the stability of a cemented femoral stem: an in vitro stair climbing test.
Jamali AA; Lozynsky AJ; Harris WH
J Arthroplasty; 2006 Jan; 21(1):122-8. PubMed ID: 16446196
[TBL] [Abstract][Full Text] [Related]
16. The influence of tibial component intramedullary stems and implant-cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty. An in vitro study.
Bourne RB; Finlay JB
Clin Orthop Relat Res; 1986 Jul; (208):95-9. PubMed ID: 3720148
[TBL] [Abstract][Full Text] [Related]
17. A parametric analysis of fixation post shape in tibial knee prostheses.
Au AG; Liggins AB; Raso VJ; Amirfazli A
Med Eng Phys; 2005 Mar; 27(2):123-34. PubMed ID: 15642508
[TBL] [Abstract][Full Text] [Related]
18. Hybrid stem fixation in revision total knee arthroplasty (TKA).
Chon JG; Lombardi AV; Berend KR
Surg Technol Int; 2004; 12():214-20. PubMed ID: 15455329
[TBL] [Abstract][Full Text] [Related]
19. Partially cemented AncaDualFit hip stems do not fail in simulated active patients.
Cristofolini L; Erani P; Teutonico AS; Traina F; Viceconti M; Toni A
Clin Biomech (Bristol, Avon); 2007 Feb; 22(2):191-202. PubMed ID: 17070631
[TBL] [Abstract][Full Text] [Related]
20. Pop-top tibial component: elimination of back-side wear with potential modularity.
Lombardi AV; Berend KR; Mallory TH
Surg Technol Int; 2004; 13():253-60. PubMed ID: 15744698
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]