These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

395 related articles for article (PubMed ID: 9418643)

  • 1. Anatomy of the posterior interosseous nerve in relation to fixation of the radial head.
    Tornetta P; Hochwald N; Bono C; Grossman M
    Clin Orthop Relat Res; 1997 Dec; (345):215-8. PubMed ID: 9418643
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variations in the anatomic relations of the posterior interosseous nerve associated with proximal forearm trauma.
    Calfee RP; Wilson JM; Wong AH
    J Bone Joint Surg Am; 2011 Jan; 93(1):81-90. PubMed ID: 21209272
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Iatrogenic posterior interosseous nerve injury: is transosseous static locked nailing of the radius feasible?
    Tabor OB; Bosse MJ; Sims SH; Kellam JF
    J Orthop Trauma; 1995; 9(5):427-9. PubMed ID: 8537847
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The course of the posterior interosseous nerve in relation to the proximal radius: is there a reliable landmark?
    Hackl M; Wegmann K; Lappen S; Helf C; Burkhart KJ; Müller LP
    Injury; 2015 Apr; 46(4):687-92. PubMed ID: 25677826
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A surgical approach to the posterior interosseous branch of the radial nerve through the brachioradialis--a cadaveric study.
    Low CK; Chew JT; Mitra AK
    Singapore Med J; 1994 Aug; 35(4):394-6. PubMed ID: 7899900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Avoiding radial nerve palsy in proximal radius shaft plating - a cadaver study.
    Schwarz AM; Hohenberger GM; Weiglein AH; Riedl R; Staresinic M; Grechenig S
    Injury; 2017 Nov; 48 Suppl 5():S34-S37. PubMed ID: 29122119
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The nonarticulating portion of the radial head: anatomic and clinical correlations for internal fixation.
    Caputo AE; Mazzocca AD; Santoro VM
    J Hand Surg Am; 1998 Nov; 23(6):1082-90. PubMed ID: 9848563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Internal fixation of radial shaft fractures: Anatomical and biomechanical principles].
    Bartoníček J; Naňka O; Tuček M
    Rozhl Chir; 2015 Oct; 94(10):425-36. PubMed ID: 26556020
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safe zone for the posterior interosseous nerve with regard to the lateral and posterior approaches to the proximal radius.
    Hohenberger GM; Schwarz AM; Maier MJ; Grechenig P; Dauwe J; Grechenig C; Krassnig R; Gänsslen A; Weiglein AH
    Surg Radiol Anat; 2018 Sep; 40(9):1025-1030. PubMed ID: 29619502
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Defining a safe zone of dissection during the extensor digitorum communis splitting approach to the proximal radius and forearm: an anatomic study.
    Schimizzi A; MacLennan A; Meier KM; Chia B; Catalano LW; Glickel SZ
    J Hand Surg Am; 2009 Sep; 34(7):1252-5. PubMed ID: 19700073
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Superficial surgical landmarks for identifying the posterior interosseous nerve.
    Tubbs RS; Salter EG; Wellons JC; Blount JP; Oakes WJ
    J Neurosurg; 2006 May; 104(5):796-9. PubMed ID: 16703886
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dorsal double-plate fixation of the distal radius.
    Rikli DA; Businger A; Babst R
    Oper Orthop Traumatol; 2005 Dec; 17(6):624-40. PubMed ID: 16369757
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Frohse's arcade is not the exclusive compression site of the radial nerve in its tunnel.
    Clavert P; Lutz JC; Adam P; Wolfram-Gabel R; Liverneaux P; Kahn JL
    Orthop Traumatol Surg Res; 2009 Apr; 95(2):114-8. PubMed ID: 19297265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Percutaneous pinning of distal radius fractures: an anatomic study demonstrating the proximity of K-wires to structures at risk.
    Chia B; Catalano LW; Glickel SZ; Barron OA; Meier K
    J Hand Surg Am; 2009; 34(6):1014-20. PubMed ID: 19643288
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vulnerability of the posterior interosseous nerve during proximal radius exposures.
    Mekhail AO; Ebraheim NA; Jackson WT; Yeasting RA
    Clin Orthop Relat Res; 1995 Jun; (315):199-208. PubMed ID: 7634668
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Anatomy of the radial nerve motor branches in the forearm.
    Abrams RA; Ziets RJ; Lieber RL; Botte MJ
    J Hand Surg Am; 1997 Mar; 22(2):232-7. PubMed ID: 9195420
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Anatomic considerations for the anterior exposure of the proximal portion of the radius.
    Mekhail AO; Ebraheim NA; Jackson WT; Yeasting RA
    J Hand Surg Am; 1996 Sep; 21(5):794-801. PubMed ID: 8891976
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The posterior interosseous nerve and the posterolateral approach to the proximal radius.
    Witt JD; Kamineni S
    J Bone Joint Surg Br; 1998 Mar; 80(2):240-2. PubMed ID: 9546452
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The anatomy of the posterior interosseous nerve as a graft.
    Elgafy H; Ebraheim NA; Yeasting RA
    J Hand Surg Am; 2000 Sep; 25(5):930-5. PubMed ID: 11040308
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
    Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
    J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.