These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
132 related articles for article (PubMed ID: 9419665)
1. Comparison of color Doppler sonography and radionuclide imaging in different degrees of torsion in rabbit testes. Frush DP; Babcock DS; Lewis AG; Paltiel HJ; Rupich R; Bove KE; Sheldon CA Acad Radiol; 1995 Nov; 2(11):945-51. PubMed ID: 9419665 [TBL] [Abstract][Full Text] [Related]
2. Acute testicular torsion: comparison of unenhanced and contrast-enhanced power Doppler US, color Doppler US, and radionuclide imaging. Coley BD; Frush DP; Babcock DS; O'Hara SM; Lewis AG; Gelfand MJ; Bove KE; Sheldon CA Radiology; 1996 May; 199(2):441-6. PubMed ID: 8668791 [TBL] [Abstract][Full Text] [Related]
3. Conventional color Doppler velocity sonography versus color Doppler energy sonography for the diagnosis of acute experimental torsion of the spermatic cord. Lee FT; Winter DB; Madsen FA; Zagzebski JA; Pozniak MA; Chosy SG; Scanlan KA AJR Am J Roentgenol; 1996 Sep; 167(3):785-90. PubMed ID: 8751701 [TBL] [Abstract][Full Text] [Related]
4. Color Doppler ultrasound compared to a radionuclide scanning of spermatic cord torsion in a canine model. Mevorach RA; Lerner RM; Greenspan BS; Russ GA; Heckler BL; Orosz JF; Rabinowitz R J Urol; 1991 Feb; 145(2):428-33. PubMed ID: 1846434 [TBL] [Abstract][Full Text] [Related]
5. Acute scrotal symptoms in boys with an indeterminate clinical presentation: comparison of color Doppler sonography and scintigraphy. Paltiel HJ; Connolly LP; Atala A; Paltiel AD; Zurakowski D; Treves ST Radiology; 1998 Apr; 207(1):223-31. PubMed ID: 9530319 [TBL] [Abstract][Full Text] [Related]
6. Suspected testicular torsion and ischemia: evaluation with color Doppler sonography. Burks DD; Markey BJ; Burkhard TK; Balsara ZN; Haluszka MM; Canning DA Radiology; 1990 Jun; 175(3):815-21. PubMed ID: 2188301 [TBL] [Abstract][Full Text] [Related]
8. Shortcomings of color Doppler sonography in the diagnosis of testicular torsion. Allen TD; Elder JS J Urol; 1995 Oct; 154(4):1508-10. PubMed ID: 7658579 [TBL] [Abstract][Full Text] [Related]
9. The normal and abnormal scrotum in children: evaluation with color Doppler sonography. Atkinson GO; Patrick LE; Ball TI; Stephenson CA; Broecker BH; Woodard JR AJR Am J Roentgenol; 1992 Mar; 158(3):613-7. PubMed ID: 1739005 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of testicular viability by power Doppler ultrasonography in experimentally induced acute testicular torsion. Kwon JW; Kim WS; Cheon JE; Kim CJ; Kim IO; Yeon KM Invest Radiol; 2005 Oct; 40(10):682-7. PubMed ID: 16189438 [TBL] [Abstract][Full Text] [Related]
12. Sonographic appearances of the epididymis in boys with acute testicular torsion but preserved testicular blood flow on color Doppler. Galina P; Dermentzoglou V; Baltogiannis N; Zarifi M Pediatr Radiol; 2015 Oct; 45(11):1661-71. PubMed ID: 26104655 [TBL] [Abstract][Full Text] [Related]
13. [Evaluation of color Doppler flow imaging in the diagnosis and differential diagnosis of spermatic cord torsion]. Zhou SG; Meng QX; Zhang ZY; Wang L; Gao JP Zhonghua Nan Ke Xue; 2003 Oct; 9(7):512-4. PubMed ID: 14628600 [TBL] [Abstract][Full Text] [Related]
14. Color Doppler sonogrphy in differentiation between testicular torsion and epididymoorchitis: report of three cases. Chou CC; Chen CS; Chu SH; Lai MK Changgeng Yi Xue Za Zhi; 1996 Mar; 19(1):90-4. PubMed ID: 8935382 [TBL] [Abstract][Full Text] [Related]
15. Sonographic differential diagnosis of acute scrotum: real-time whirlpool sign, a key sign of torsion. Vijayaraghavan SB J Ultrasound Med; 2006 May; 25(5):563-74. PubMed ID: 16632779 [TBL] [Abstract][Full Text] [Related]
16. Which is the most sensitive study for testicular torsion in children--Doppler sonography or testicular nuclear scan? Babcock DS AJR Am J Roentgenol; 1995 Jul; 165(1):224. PubMed ID: 7785610 [No Abstract] [Full Text] [Related]
17. Color Doppler sonography in the diagnosis of acute scrotum in boys. Weber DM; Rösslein R; Fliegel C Eur J Pediatr Surg; 2000 Aug; 10(4):235-41. PubMed ID: 11034513 [TBL] [Abstract][Full Text] [Related]
18. Power Doppler US of the normal prepubertal testis: does it live up to its promises? Albrecht T; Lotzof K; Hussain HK; Shedden D; Cosgrove DO; de Bruyn R Radiology; 1997 Apr; 203(1):227-31. PubMed ID: 9122398 [TBL] [Abstract][Full Text] [Related]
19. Doppler contrast sonography for detecting reduced perfusion in experimental ischemia of prepubertal rabbit testes. O'Hara SM; Frush DP; Babcock DS; Lewis AG; Barr LL; Bukowski TP; Kline-Fath BM; Sheldon CA Acad Radiol; 1996 Apr; 3(4):319-24. PubMed ID: 8796681 [TBL] [Abstract][Full Text] [Related]
20. Effects of unilateral testicular torsion on the blood flow of contralateral testis--an experimental study on dogs. Tarhan F; Erbay ME; Erdogan E; Ozgül A; Kuyumcuoglu U Scand J Urol Nephrol; 2000 Aug; 34(4):229-32. PubMed ID: 11095079 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]