BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 9420598)

  • 1. Prosthetic metals impair murine immune response and cytokine release in vivo and in vitro.
    Wang JY; Wicklund BH; Gustilo RB; Tsukayama DT
    J Orthop Res; 1997 Sep; 15(5):688-99. PubMed ID: 9420598
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inhibition of T and B cell proliferation by titanium, cobalt, and chromium: role of IL-2 and IL-6.
    Wang JY; Tsukayama DT; Wicklund BH; Gustilo RB
    J Biomed Mater Res; 1996 Dec; 32(4):655-61. PubMed ID: 8953156
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Soluble ions more than particulate cobalt-alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal-induced lymphocyte reactivity.
    Caicedo MS; Pennekamp PH; McAllister K; Jacobs JJ; Hallab NJ
    J Biomed Mater Res A; 2010 Jun; 93(4):1312-21. PubMed ID: 19844976
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of chromium and cobalt ions on primary human lymphocytes in vitro.
    Akbar M; Brewer JM; Grant MH
    J Immunotoxicol; 2011 Jun; 8(2):140-9. PubMed ID: 21446789
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Human monocyte/macrophage response to cobalt-chromium corrosion products and titanium particles in patients with total joint replacements.
    Lee SH; Brennan FR; Jacobs JJ; Urban RM; Ragasa DR; Glant TT
    J Orthop Res; 1997 Jan; 15(1):40-9. PubMed ID: 9066525
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Variation in cytokines induced by particles from different prosthetic materials.
    Haynes DR; Boyle SJ; Rogers SD; Howie DW; Vernon-Roberts B
    Clin Orthop Relat Res; 1998 Jul; (352):223-30. PubMed ID: 9678051
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of hydroxyapatite particulate debris on the production of cytokines and proteases in human fibroblasts.
    Ninomiya JT; Struve JA; Stelloh CT; Toth JM; Crosby KE
    J Orthop Res; 2001 Jul; 19(4):621-8. PubMed ID: 11518271
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Titanium, chromium and cobalt ions modulate the release of bone-associated cytokines by human monocytes/macrophages in vitro.
    Wang JY; Wicklund BH; Gustilo RB; Tsukayama DT
    Biomaterials; 1996 Dec; 17(23):2233-40. PubMed ID: 8968517
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.
    Haynes DR; Rogers SD; Hay S; Pearcy MJ; Howie DW
    J Bone Joint Surg Am; 1993 Jun; 75(6):825-34. PubMed ID: 8314823
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of stainless steel, cobalt-chromium, titanium alloy, and titanium on the respiratory burst activity of human polymorphonuclear leukocytes.
    Pascual A; Tsukayama DT; Wicklund BH; Bechtold JE; Merritt K; Peterson PK; Gustilo RB
    Clin Orthop Relat Res; 1992 Jul; (280):281-8. PubMed ID: 1319292
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Orthopedic implant cobalt-alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy-based particles in vitro, in human osteoblasts, fibroblasts, and macrophages.
    Dalal A; Pawar V; McAllister K; Weaver C; Hallab NJ
    J Biomed Mater Res A; 2012 Aug; 100(8):2147-58. PubMed ID: 22615169
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The role of adsorbed endotoxin in particle-induced stimulation of cytokine release.
    Cho DR; Shanbhag AS; Hong CY; Baran GR; Goldring SR
    J Orthop Res; 2002 Jul; 20(4):704-13. PubMed ID: 12168658
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of bulk versus particulate titanium and cobalt chrome alloy implanted into the rabbit tibia.
    Goodman SB; Fornasier VL; Lee J; Kei J
    J Biomed Mater Res; 1990 Nov; 24(11):1539-49. PubMed ID: 2279985
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of particle phagocytosis and metallic wear particles on osteoclast formation and bone resorption in vitro.
    Neale SD; Haynes DR; Howie DW; Murray DW; Athanasou NA
    J Arthroplasty; 2000 Aug; 15(5):654-62. PubMed ID: 10960005
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of UV-photofunctionalization on the time-related bioactivity of titanium and chromium-cobalt alloys.
    Att W; Hori N; Iwasa F; Yamada M; Ueno T; Ogawa T
    Biomaterials; 2009 Sep; 30(26):4268-76. PubMed ID: 19473697
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Differences in metal ion release following cobalt-chromium and oxidized zirconium total knee arthroplasty.
    Garrett S; Jacobs N; Yates P; Smith A; Wood D
    Acta Orthop Belg; 2010 Aug; 76(4):513-20. PubMed ID: 20973359
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Low dose metal particles can induce monocyte/macrophage survival.
    Lacey DC; De Kok B; Clanchy FI; Bailey MJ; Speed K; Haynes D; Graves SE; Hamilton JA
    J Orthop Res; 2009 Nov; 27(11):1481-6. PubMed ID: 19459209
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of synthetic agonists of toll-like receptor 9 on canine lymphocyte proliferation and cytokine production in vitro.
    Im Hof M; Williamson L; Summerfield A; Balmer V; Dutoit V; Kandimalla ER; Yu D; Zurbriggen A; Doherr MG; Peel J; Roosje PJ
    Vet Immunol Immunopathol; 2008 Jul; 124(1-2):120-31. PubMed ID: 18452997
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A study on the effects of particulate metals of orthopaedic interest on murine macrophages in vitro.
    Rae T
    J Bone Joint Surg Br; 1975 Nov; 57(4):444-50. PubMed ID: 1194310
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Expression of inflammatory cytokines, RANKL and OPG induced by titanium, cobalt-chromium and polyethylene particles.
    Masui T; Sakano S; Hasegawa Y; Warashina H; Ishiguro N
    Biomaterials; 2005 May; 26(14):1695-702. PubMed ID: 15576143
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.