These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 9422163)

  • 1. The suction test for oesophageal placement of the endotracheal tube using an oesophageal detector device: caution is required with inexperienced operators.
    Knottenbelt JD
    Eur J Emerg Med; 1994 Dec; 1(4):173-4. PubMed ID: 9422163
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An assessment of a tracheal tube introducer as an endotracheal tube placement confirmation device.
    Bair AE; Laurin EG; Schmitt BJ
    Am J Emerg Med; 2005 Oct; 23(6):754-8. PubMed ID: 16182983
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sonomatic confirmation of tracheal intubation using the SCOTI.
    Petroianu G; Maleck W; Bergler W; Rüfer R
    Prehosp Disaster Med; 1997; 12(2):149-53. PubMed ID: 10187000
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Extubation force: tape versus endotracheal tube holders.
    Carlson J; Mayrose J; Krause R; Jehle D
    Ann Emerg Med; 2007 Dec; 50(6):686-91. PubMed ID: 17599694
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Frova intubating catheter position can be determined with aspirating oesophageal detection device.
    Kadry T; Harvey M; Wallace M; Imrie J
    Emerg Med Australas; 2007 Jun; 19(3):203-6. PubMed ID: 17564685
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endotracheal tube introducer for failed intubations: a variant of the gum elastic bougie.
    Moscati R; Jehle D; Christiansen G; D'Aprix T; Radford J; Connery C; Billittier A
    Ann Emerg Med; 2000 Jul; 36(1):52-6. PubMed ID: 10874235
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
    Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
    Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Parker Flex-Tip tracheal tube makes endotracheal intubation with the Bullard laryngoscope easier and faster.
    Suzuki A; Tampo A; Abe N; Otomo S; Minami S; Henderson JJ; Iwasaki H
    Eur J Anaesthesiol; 2008 Jan; 25(1):43-7. PubMed ID: 17666155
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of the King-LT to endotracheal intubation and Combitube in a simulated difficult airway.
    Russi CS; Miller L; Hartley MJ
    Prehosp Emerg Care; 2008; 12(1):35-41. PubMed ID: 18189175
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preliminary case series report: use of the laryngeal mask airway Fastrach oral endotracheal tube with the Bullard laryngoscope.
    Spain K
    AANA J; 2008 Aug; 76(4):265-7. PubMed ID: 18777810
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Disposable laryngeal tube suction--a randomized comparison of two insertion techniques performed by novice users in anaesthetised patients.
    Schalk R; Scheller B; Habler OP; Meier J; Meininger D; Byhahn C
    Resuscitation; 2008 Mar; 76(3):364-8. PubMed ID: 17935855
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reduced burden of bacterial airway colonization with a novel silver-coated endotracheal tube in a randomized multiple-center feasibility study.
    Rello J; Kollef M; Diaz E; Sandiumenge A; del Castillo Y; Corbella X; Zachskorn R
    Crit Care Med; 2006 Nov; 34(11):2766-72. PubMed ID: 16957639
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The oesophageal detector device. An assessment of accuracy and ease of use by paramedics.
    Donahue PL
    Anaesthesia; 1994 Oct; 49(10):863-5. PubMed ID: 7802180
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Fenem CO2 detector device. An apparatus to prevent unnoticed oesophageal intubation.
    Denman WT; Hayes M; Higgins D; Wilkinson DJ
    Anaesthesia; 1990 Jun; 45(6):465-7. PubMed ID: 2116738
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New methods for direct verification of correct endotracheal tube placement.
    Angelotti T; Brock-Utne J
    Anesth Analg; 2007 Oct; 105(4):1168; author reply 1169. PubMed ID: 17898410
    [No Abstract]   [Full Text] [Related]  

  • 16. Use of a disposable carbon dioxide detector with emergency intubation in a hyperbaric chamber.
    Larson SR; Sutton T; Koch S; Butler BD
    Aviat Space Environ Med; 1993 Dec; 64(12):1133-4. PubMed ID: 8291995
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of a customised endotracheal tube for tracheostomy in the large neck.
    Coatesworth AP
    Int J Clin Pract; 2002; 56(1):52. PubMed ID: 11831836
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extubation force: a comparison of adhesive tape, non-adhesive tape and a commercial endotracheal tube holder.
    Owen R; Castle N; Hann H; Reeves D; Naidoo R; Naidoo S
    Resuscitation; 2009 Nov; 80(11):1296-300. PubMed ID: 19726121
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Verification of endotracheal tube placement by prehospital providers: is a portable fiberoptic bronchoscope of value?
    Angelotti T; Weiss EL; Lemmens HJ; Brock-Utne J
    Air Med J; 2006; 25(2):74-8; discussion 78-80. PubMed ID: 16516118
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Verification of pediatric endotracheal tube placement.
    Wagner CM
    Air Med J; 2004; 23(2):10-2. PubMed ID: 15014388
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.