BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 9423317)

  • 1. [Active MR tracking system at 0.2T MR, a preliminary report: real time position tracking on interventional MR].
    Aoki S; Nanbu A; Araki T; Shimazu N; Ichikawa T; Kumagai H; Kachi K; Araki T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1997 Nov; 57(13):877-9. PubMed ID: 9423317
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Active MR tracking on a 0.2 Tesla MR imager.
    Aoki S; Nanbu A; Araki T; Ma X; Araki T; Kumagai H; Dumoulin CL; Darrow RD; Shimazu N; Tsukamoto T; Moriya H; Nakajima H
    Radiat Med; 1999; 17(3):251-7. PubMed ID: 10440117
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intravascular MR tracking catheter: preliminary experimental evaluation.
    Leung DA; Debatin JF; Wildermuth S; McKinnon GC; Holtz D; Dumoulin CL; Darrow RD; Hofmann E; von Schulthess GK
    AJR Am J Roentgenol; 1995 May; 164(5):1265-70. PubMed ID: 7717244
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Active instrumental guidance in interventional MR tomography: introduction to a new concept].
    Wildermuth S; Erhart P; Leung DA; Göhde S; Schoenenberger A; Debatin JF
    Rofo; 1998 Jul; 169(1):77-84. PubMed ID: 9711287
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MR-guided intravascular catheter manipulation: feasibility of both active and passive tracking in experimental study and initial clinical applications.
    Araki T; Aoki S; Ishigame K; Kumagai H; Nanbu A; Hori M; Ueki J; Komiyama T; Araki T
    Radiat Med; 2002; 20(1):1-8. PubMed ID: 12002598
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Application of MR-guided intravascular procedures by passive tracking utilizing the magnetic susceptibility effect: a preliminary report].
    Araki T; Aoki S; Nambu A; Hori M; Ishigame K; Araki T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1999 Feb; 59(3):79-81. PubMed ID: 10339985
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Laparoscopic and general surgery guided by open interventional magnetic resonance].
    Lauro A; Gould SW; Cirocchi R; Giustozzi G; Darzi A
    Minerva Chir; 2004 Oct; 59(5):507-16. PubMed ID: 15494679
    [TBL] [Abstract][Full Text] [Related]  

  • 8. MR-guided intravascular procedures: real-time parameter control and automated slice positioning with active tracking coils.
    Bock M; Volz S; Zühlsdorff S; Umathum R; Fink C; Hallscheidt P; Semmler W
    J Magn Reson Imaging; 2004 May; 19(5):580-9. PubMed ID: 15112307
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-time catheter tracking and adaptive imaging.
    Elgort DR; Wong EY; Hillenbrand CM; Wacker FK; Lewin JS; Duerk JL
    J Magn Reson Imaging; 2003 Nov; 18(5):621-6. PubMed ID: 14579407
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Real-time magnetic resonance-guided placement of retrievable inferior vena cava filters: comparison with fluoroscopic guidance with use of in vitro and animal models.
    Shih MC; Rogers WJ; Hagspiel KD
    J Vasc Interv Radiol; 2006 Feb; 17(2 Pt 1):327-33. PubMed ID: 16517779
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous ultrasound and MRI system for breast biopsy: compatibility assessment and demonstration in a dual modality phantom.
    Tang AM; Kacher DF; Lam EY; Wong KK; Jolesz FA; Yang ES
    IEEE Trans Med Imaging; 2008 Feb; 27(2):247-54. PubMed ID: 18334446
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo MR-tracking based on magnetic signature selective excitation.
    Felfoul O; Mathieu JB; Beaudoin G; Martel S
    IEEE Trans Med Imaging; 2008 Jan; 27(1):28-35. PubMed ID: 18270059
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [New method of MR-guided mammary biopsy].
    Thiele J; Schneider JP; Franke P; Lieberenz S; Schmidt F
    Rofo; 1998 Apr; 168(4):374-9. PubMed ID: 9589101
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Phase-field dithering for active catheter tracking.
    Dumoulin CL; Mallozzi RP; Darrow RD; Schmidt EJ
    Magn Reson Med; 2010 May; 63(5):1398-403. PubMed ID: 20432311
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feasibility of stent-graft placement with real-time MR fluoroscopy in a nonrigid aortic phantom.
    Attia C; Abdulrazzaq S; Huet L; Saint-James H; Beuf O; Farhat F; Douek P
    J Vasc Interv Radiol; 2008 Sep; 19(9):1354-60. PubMed ID: 18725099
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Truly hybrid interventional MR/X-ray system: investigation of in vivo applications.
    Fahrig R; Butts K; Wen Z; Saunders R; Kee ST; Sze DY; Daniel BL; Laerum F; Pelc NJ
    Acad Radiol; 2001 Dec; 8(12):1200-7. PubMed ID: 11770916
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Superconducting open-configuration MR imaging system for image-guided therapy.
    Schenck JF; Jolesz FA; Roemer PB; Cline HE; Lorensen WE; Kikinis R; Silverman SG; Hardy CJ; Barber WD; Laskaris ET
    Radiology; 1995 Jun; 195(3):805-14. PubMed ID: 7754014
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Magnetic resonance imaging-guided renal artery stent placement in a Swine model: comparison of two tracking techniques.
    Frericks BB; Elgort DR; Hillenbrand C; Duerk JL; Lewin JS; Wacker FK
    Acta Radiol; 2009 Jan; 50(1):21-7. PubMed ID: 19101851
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tracking of an interventional catheter with a ferromagnetic tip using dual-echo projections.
    Zhang K; Maier F; Krafft AJ; Umathum R; Semmler W; Bock M
    J Magn Reson; 2013 Sep; 234():176-83. PubMed ID: 23892103
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Musculoskeletal biopsies in an open 0.5-T-MR system].
    Pretzsch M; Scholz R; Moche M; Thomas M; Tannapfel A; von Salis-Soglio G
    Z Orthop Ihre Grenzgeb; 2005; 143(3):365-74. PubMed ID: 15977129
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.