138 related articles for article (PubMed ID: 9429700)
21. Fetal oxygen saturation and uterine contractions during labor.
East CE; Dunster KR; Colditz PB
Am J Perinatol; 1998 Jun; 15(6):345-9. PubMed ID: 9722053
[TBL] [Abstract][Full Text] [Related]
22. Fetal pulse oximetry and fetal heart rate monitoring during stage II of labour.
Langer B; Carbonne B; Goffinet F; Le Gouëff F; Berkane N; Laville M
Eur J Obstet Gynecol Reprod Biol; 1997 Mar; 72 Suppl():S57-61. PubMed ID: 9134414
[TBL] [Abstract][Full Text] [Related]
23. [Preliminary study of the use of fetal pulse oximetry during labor].
Carbonne B; Audibert F; Segard L; Sebban E; Beyaert B; Cabrol D; Papiernik E
J Gynecol Obstet Biol Reprod (Paris); 1995; 24(7):756-62. PubMed ID: 8568186
[TBL] [Abstract][Full Text] [Related]
24. Is the correlation between fetal oxygen saturation and blood pH sufficient for the use of fetal pulse oximetry?
Rijnders RJ; Mol BW; Reuwer PJ; Drogtrop AP; Vernooij MM; Visser GH
J Matern Fetal Neonatal Med; 2002 Feb; 11(2):80-3. PubMed ID: 12375547
[TBL] [Abstract][Full Text] [Related]
25. [The management of labor overweight women with intrapartum fetal oxygen saturation monitoring].
Skoczylas M; Zdziennicki A; Laudański T
Ginekol Pol; 2001 Dec; 72(12):1189-93. PubMed ID: 11883234
[TBL] [Abstract][Full Text] [Related]
26. The relationship between oxygen saturation and pH in umbilical blood: implications for intrapartum fetal oxygen saturation monitoring.
Dildy GA; Thorp JA; Yeast JD; Clark SL
Am J Obstet Gynecol; 1996 Sep; 175(3 Pt 1):682-7. PubMed ID: 8828434
[TBL] [Abstract][Full Text] [Related]
27. [Fetal oxygen saturation during normal delivery].
Nikolov A; Dimitrov A; Vakrilkova L; Iar'kova N
Akush Ginekol (Sofiia); 2000; 40(4):3-6. PubMed ID: 11288630
[TBL] [Abstract][Full Text] [Related]
28. Multicenter study on the clinical value of fetal pulse oximetry. I. Methodologic evaluation. The French Study Group on Fetal Pulse Oximetry.
Goffinet F; Langer B; Carbonne B; Berkane N; Tardif D; Le Goueff F; Laville M; Maillard F
Am J Obstet Gynecol; 1997 Nov; 177(5):1238-46. PubMed ID: 9396924
[TBL] [Abstract][Full Text] [Related]
29. Do fetal pulse oximetry readings at delivery correlate with cord blood oxygenation and acidaemia?
McNamara H; Chung DC; Lilford R; Johnson N
Br J Obstet Gynaecol; 1992 Sep; 99(9):735-8. PubMed ID: 1420012
[TBL] [Abstract][Full Text] [Related]
30. [Reference values range of the fetal oxygen saturation and its dispersal during labor without cardiotocographic evidence for fetal distress].
Nikolov A; Dimitrov A; Vakrilova L; Iarŭkova N; Tsankova M; Krŭsteva K
Akush Ginekol (Sofiia); 2005; 44(1):24-31. PubMed ID: 15853008
[TBL] [Abstract][Full Text] [Related]
31. Fetal blood saturation during the 1st and 2nd stage of labor and its relation to the neonatal outcome.
Leszczyńska-Gorzelak B; Poniedziałek-Czajkowska E; Oleszczuk J
Gynecol Obstet Invest; 2002; 54(3):159-63. PubMed ID: 12571438
[TBL] [Abstract][Full Text] [Related]
32. [The usefulness of the intrapartum fetal pulse oximetry in anticipating the neonatal outcome].
Leszczyńska-Gorzelak B; Poniedziałek-Czajkowska E; Zych I; Grzechnik M; Oleszczuk J
Ginekol Pol; 2001 Dec; 72(12):1183-8. PubMed ID: 11883233
[TBL] [Abstract][Full Text] [Related]
33. [Monitoring of labour and delivery in the presence of meconium stained amniotic fluid by pulse oximetry].
Skoczylas M; Gołab-Lipińska M; Krajewski P; Laudański T
Ginekol Pol; 2006 Oct; 77(10):783-7. PubMed ID: 17219811
[TBL] [Abstract][Full Text] [Related]
34. Predictive agreement between the fetal arterial oxygen saturation and fetal scalp pH: results of the German multicenter study.
Kühnert M; Seelbach-Göebel B; Butterwegge M
Am J Obstet Gynecol; 1998 Feb; 178(2):330-5. PubMed ID: 9500495
[TBL] [Abstract][Full Text] [Related]
35. Fetal monitoring with pulse oximetry.
Johnson N; Johnson VA; Fisher J; Jobbings B; Bannister J; Lilford RJ
Br J Obstet Gynaecol; 1991 Jan; 98(1):36-41. PubMed ID: 1998630
[TBL] [Abstract][Full Text] [Related]
36. Multicenter study on the clinical value of fetal pulse oximetry. II. Compared predictive values of pulse oximetry and fetal blood analysis. The French Study Group on Fetal Pulse Oximetry.
Carbonne B; Langer B; Goffinet F; Audibert F; Tardif D; Le Goueff F; Laville M; Maillard F
Am J Obstet Gynecol; 1997 Sep; 177(3):593-8. PubMed ID: 9322629
[TBL] [Abstract][Full Text] [Related]
37. Computerised intrapartum diagnosis of fetal hypoxia based on fetal heart rate monitoring and fetal pulse oximetry recordings utilising wavelet analysis and neural networks.
Salamalekis E; Thomopoulos P; Giannaris D; Salloum I; Vasios G; Prentza A; Koutsouris D
BJOG; 2002 Oct; 109(10):1137-42. PubMed ID: 12387467
[TBL] [Abstract][Full Text] [Related]
38. [The value of measuring blood pH in fetal monitoring during labour (author's transl)].
Pontonnier G; Grandjean H; Derache P; Reme JM; Boulogne M; de Mouzon J
J Gynecol Obstet Biol Reprod (Paris); 1978 Sep; 7(6):1065-77. PubMed ID: 32197
[TBL] [Abstract][Full Text] [Related]
39. The accuracy of fetal pulse oximetry in the second stage of labour.
Johnson N; Johnson VA; Bannister J; Lilford RJ
J Perinat Med; 1991; 19(4):297-303. PubMed ID: 1960633
[TBL] [Abstract][Full Text] [Related]
40. Prediction of umbilical artery base excess by intrapartum fetal oxygen saturation monitoring.
Alshimmiri M; Bocking AD; Gagnon R; Natale R; Richardson BS
Am J Obstet Gynecol; 1997 Oct; 177(4):775-9. PubMed ID: 9369818
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]