  • 61. Film dosimetry in the peripheral region using multiple sensitometric curves.
    Stern RL; Kurylo J; Siantar CH; Lehmann J; Goldberg Z
    Med Phys; 2004 Feb; 31(2):327-32. PubMed ID: 15000618
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Characteristics of Gafchromic XR-RV2 radiochromic film.
    Blair A; Meyer J
    Med Phys; 2009 Jul; 36(7):3050-8. PubMed ID: 19673204
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Radiochromic film dosimetry with flatbed scanners: a fast and accurate method for dose calibration and uniformity correction with single film exposure.
    Menegotti L; Delana A; Martignano A
    Med Phys; 2008 Jul; 35(7):3078-85. PubMed ID: 18697531
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.
    Niu H; Hsi WC; Chu JC; Kirk MC; Kouwenhoven E
    Med Phys; 2004 Dec; 31(12):3372-7. PubMed ID: 15651620
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Fluorescent light effects on FWT-60 radiochromic film.
    Butson MJ; Cheung T; Yu PK
    Phys Med Biol; 2005 Aug; 50(16):N209-13. PubMed ID: 16077218
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Radiochromic film dosimetry of HDR (192)Ir source radiation fields.
    Aldelaijan S; Mohammed H; Tomic N; Liang LH; Deblois F; Sarfehnia A; Abdel-Rahman W; Seuntjens J; Devic S
    Med Phys; 2011 Nov; 38(11):6074-83. PubMed ID: 22047372
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Measurement of high energy x-ray beam penumbra with Gafchromic EBT radiochromic film.
    Cheung T; Butson MJ; Yu PK
    Med Phys; 2006 Aug; 33(8):2912-4. PubMed ID: 16964868
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance.
    Aland T; Kairn T; Kenny J
    Australas Phys Eng Sci Med; 2011 Jun; 34(2):251-60. PubMed ID: 21465275
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.
    McCaw TJ; Micka JA; DeWerd LA
    Med Phys; 2014 May; 41(5):052104. PubMed ID: 24784393
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Analysis of various beamlet sizes for IMRT with 6 MV photons.
    Sohn JW; Dempsey JF; Suh TS; Low DA
    Med Phys; 2003 Sep; 30(9):2432-9. PubMed ID: 14528965
    [TBL] [Abstract][Full Text] [Related]  

  • 71. The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics.
    McLaughlin WL; Soares CG; Sayeg JA; McCullough EC; Kline RW; Wu A; Maitz AH
    Med Phys; 1994 Mar; 21(3):379-88. PubMed ID: 8208212
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Dependence of radiochromic film optical density post-exposure kinetics on dose and dose fractionation.
    Ali I; Costescu C; Vicic M; Dempsey JF; Williamson JF
    Med Phys; 2003 Aug; 30(8):1958-67. PubMed ID: 12945961
    [TBL] [Abstract][Full Text] [Related]  

  • 73. The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapy.
    Arnfield MR; Otto K; Aroumougame VR; Alkins RD
    Med Phys; 2005 Jan; 32(1):12-8. PubMed ID: 15719949
    [TBL] [Abstract][Full Text] [Related]  

  • 74. [Sensitivity characteristic that uses optical filters in GafChromic radiation dosimetry].
    Kamomae T; Miyabe Y; Nakata M; Yano S; Okada T; Takakura T; Fujimoto T; Koshida K; Kikuchi Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2007 Nov; 63(11):1253-6. PubMed ID: 18187910
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Quantitative optical densitometry with scanning-laser film digitizers.
    Dempsey JF; Low DA; Kirov AS; Williamson JF
    Med Phys; 1999 Aug; 26(8):1721-31. PubMed ID: 10501072
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Optical density changes of Gafchromic MD-55 film resulting from laser light exposure at wavelengths of 671 nm and 633 nm.
    Sullivan PR; Hasson BF; Grossman CH; Simpson LD
    Med Phys; 2000 Jan; 27(1):245-51. PubMed ID: 10659764
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Regional silver content of radiographic film determined by x-ray fluorescence compared with optical densitometry.
    Oldendorf WH; Astrahan MA
    Med Phys; 1983; 10(2):246-7. PubMed ID: 6865865
    [TBL] [Abstract][Full Text] [Related]  

  • 78. The use of GAFchromic film to determine the absolute activity of beta emitters.
    Fox RA; Barker P; Smart G
    Phys Med Biol; 1999 Apr; 44(4):833-42. PubMed ID: 10232799
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Portable and wide-range solid-state transmission densitometer for quality control in film radiography.
    Aramburo JM; Gonzalez SS; Toledo JT
    J Med Phys; 2010 Jul; 35(3):151-3. PubMed ID: 20927222
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Tests for evaluating laser film digitizers.
    Meeder RJ; Jaffray DA; Munro P
    Med Phys; 1995 May; 22(5):635-42. PubMed ID: 7643804
    [TBL] [Abstract][Full Text] [Related]  