These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 9436944)

  • 1. Comparison of computer simulated and phantom measured phase variance in the study of trabecular bone.
    Mihalopoulou E; Allein S; Luypaert R; Eisendrath H; Bezerianos A; Panayiotakis G
    Magn Reson Imaging; 1998; 16(1):29-36. PubMed ID: 9436944
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computer simulations for the optimization of magnetic resonance phase imaging applied in the study of trabecular bone.
    Mihalopoulou E; Allein S; Luypaert R; Eisendrath H; Panayiotakis G
    Comput Methods Programs Biomed; 1999 Jul; 60(1):1-10. PubMed ID: 10430458
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Investigation of MR decay rates in microphantom models of trabecular bone.
    Selby K; Majumdar S; Newitt DC; Genant HK
    J Magn Reson Imaging; 1996; 6(3):549-59. PubMed ID: 8724422
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of trabecular bone by dipolar demagnetizing field MRI.
    Capuani S; Curzi F; Alessandri FM; Maraviglia B; Bifone A
    Magn Reson Med; 2001 Oct; 46(4):683-9. PubMed ID: 11590644
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of technical factors affecting the quantification of trabecular bone structure using magnetic resonance imaging.
    Majumdar S; Newitt D; Jergas M; Gies A; Chiu E; Osman D; Keltner J; Keyak J; Genant H
    Bone; 1995 Oct; 17(4):417-30. PubMed ID: 8573417
    [TBL] [Abstract][Full Text] [Related]  

  • 6. MR phase imaging to quantify bone volume fraction: computer simulations and in vivo measurements.
    Allein S; Mihalopoulou E; Luypaert R; Louis O; Panayiotakis G; Eisendrath H
    Magn Reson Imaging; 2000 Apr; 18(3):275-9. PubMed ID: 10745136
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of trabecular structure using high resolution magnetic resonance imaging.
    Majumdar S; Genant HK
    Stud Health Technol Inform; 1997; 40():81-96. PubMed ID: 10168884
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Local plate/rod descriptors of 3D trabecular bone micro-CT images from medial axis topologic analysis.
    Peyrin F; Attali D; Chappard C; Benhamou CL
    Med Phys; 2010 Aug; 37(8):4364-76. PubMed ID: 20879596
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The vertebral trabecular model revisited: magnetic field distribution in the vicinity of osseous disconnections.
    Kraiger M; Schnizer B; Stollberger R
    Phys Med Biol; 2016 Dec; 61(23):N618-N631. PubMed ID: 27811401
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantitative study of the susceptibility difference between trabecular bone and bone marrow: computer simulations.
    Majumdar S
    Magn Reson Med; 1991 Nov; 22(1):101-10. PubMed ID: 1798385
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accurate quantification of width and density of bone structures by computed tomography.
    Hangartner TN; Short DF
    Med Phys; 2007 Oct; 34(10):3777-84. PubMed ID: 17985623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images.
    Gordon CL; Webber CE; Christoforou N; Nahmias C
    Med Phys; 1997 Apr; 24(4):585-93. PubMed ID: 9127312
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A hyperboliod representation of the bone-marrow interface within 3D NMR images of trabecular bone: applications to skeletal dosimetry.
    Rajon DA; Shah AP; Watchman CJ; Brindle JM; Bolch WE
    Phys Med Biol; 2003 Jun; 48(12):1721-40. PubMed ID: 12870579
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Analyses of restricted diffusion of water molecules using trabecular bone phantom].
    Minami T; Miyati T; Ueda Y; Kan H; Kitanaka A; Kasai H; Arai N; Hara M; Shibamoto Y; Yokoti S
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2011; 67(6):634-9. PubMed ID: 21720071
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Phantom studies simulating the impact of trabecular structure on marrow relaxation time, T2'.
    Engelke K; Majumdar S; Genant HK
    Magn Reson Med; 1994 Apr; 31(4):380-7. PubMed ID: 8208113
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A fully automated method for accurate measurement of geometrical distortion in magnetic resonance imaging of a 3D-lattice phantom.
    Mangione S; Acquaviva R; Garbo G
    Magn Reson Imaging; 2019 Apr; 57():8-18. PubMed ID: 30393141
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetic susceptibility effects of trabecular bone on magnetic resonance imaging of bone marrow.
    Rosenthal H; Thulborn KR; Rosenthal DI; Kim SH; Rosen BR
    Invest Radiol; 1990 Feb; 25(2):173-8. PubMed ID: 2312252
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Velocity dispersion in trabecular bone: influence of multiple scattering and of absorption.
    Haïat G; Lhémery A; Renaud F; Padilla F; Laugier P; Naili S
    J Acoust Soc Am; 2008 Dec; 124(6):4047-58. PubMed ID: 19206827
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of trabecular bone thickness in the limited resolution regime of in vivo MRI by fuzzy distance transform.
    Saha PK; Wehrli FW
    IEEE Trans Med Imaging; 2004 Jan; 23(1):53-62. PubMed ID: 14719687
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Voxel size effects in three-dimensional nuclear magnetic resonance microscopy performed for trabecular bone dosimetry.
    Rajon DA; Jokisch DW; Patton PW; Shah AP; Bolch WE
    Med Phys; 2000 Nov; 27(11):2624-35. PubMed ID: 11128316
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.