BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 9440781)

  • 1. Reconstruction of orbital floor fractures with maxillary bone.
    Lee HH; Alcaraz N; Reino A; Lawson W
    Arch Otolaryngol Head Neck Surg; 1998 Jan; 124(1):56-9. PubMed ID: 9440781
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new option for the reconstruction of orbital floor defects with heterologous cortical bone.
    Ozel B; Findikcioglu K; Sezgin B; Guney K; Barut I; Ozmen S
    J Craniomaxillofac Surg; 2015 Oct; 43(8):1583-8. PubMed ID: 26228594
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Antral Wall Approach for Reconstruction of Orbital Floor Fractures Using Anterior Maxillary Sinus Bone Grafts.
    Emodi O; Nseir S; Shilo D; Srouji H; Rachmiel A
    J Craniofac Surg; 2018 Jun; 29(4):e421-e426. PubMed ID: 29521754
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of post-operative outcomes of graft materials used in reconstruction of blow-out fractures.
    Düzgün S; Kayahan Sirkeci B
    Ulus Travma Acil Cerrahi Derg; 2020 Jul; 26(4):538-544. PubMed ID: 32589255
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Results of treatment of orbital fractures with polydioxanone sheet].
    Kos M; Brusco D; Engelke W
    Polim Med; 2006; 36(4):31-6. PubMed ID: 17402230
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reconstruction of orbital floor blow-out fractures with autogenous iliac crest bone: a retrospective study including maxillofacial and ophthalmology perspectives.
    O'Connell JE; Hartnett C; Hickey-Dwyer M; Kearns GJ
    J Craniomaxillofac Surg; 2015 Mar; 43(2):192-8. PubMed ID: 25534042
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Traumatic orbital floor fractures: repair with autogenous bone grafts in a tertiary trauma center.
    Zunz E; Blanc O; Leibovitch I
    J Oral Maxillofac Surg; 2012 Mar; 70(3):584-92. PubMed ID: 21664743
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of anatomically drop-shaped bioactive glass S53P4 implants in the reconstruction of orbital floor fractures--A prospective long-term follow-up study.
    Stoor P; Mesimäki K; Lindqvist C; Kontio R
    J Craniomaxillofac Surg; 2015 Jul; 43(6):969-75. PubMed ID: 25957104
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endoscopic transantral orbital floor repair with antral bone grafts.
    Nishiike S; Nagai M; Nakagawa A; Konishi M; Kato T; Sakata Y; Yasukura T; Harada T
    Arch Otolaryngol Head Neck Surg; 2005 Oct; 131(10):911-5. PubMed ID: 16230596
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reconstruction of orbital floor fractures using bioactive glass.
    Kinnunen I; Aitasalo K; Pöllönen M; Varpula M
    J Craniomaxillofac Surg; 2000 Aug; 28(4):229-34. PubMed ID: 11110155
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reconstruction of traumatic orbital floor fractures with resorbable mesh plate.
    Tuncer S; Yavuzer R; Kandal S; Demir YH; Ozmen S; Latifoglu O; Atabay K
    J Craniofac Surg; 2007 May; 18(3):598-605. PubMed ID: 17538325
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term outcomes of ultra-thin porous polyethylene implants used for reconstruction of orbital floor defects.
    Ozturk S; Sengezer M; Isik S; Turegun M; Deveci M; Cil Y
    J Craniofac Surg; 2005 Nov; 16(6):973-7. PubMed ID: 16327542
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nasal endoscopy-assisted reconstruction of orbital floor blowout fractures using temporal fascia grafting.
    Yan Z; Zhou Z; Song X
    J Oral Maxillofac Surg; 2012 May; 70(5):1119-22. PubMed ID: 22365979
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the outcomes of using iliac bone graft for reconstruction of traumatic orbital floor fractures.
    Alasady MS; Kanj A; Kanj AEH
    J Popul Ther Clin Pharmacol; 2022; 29(2):e71-e78. PubMed ID: 35848199
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pure orbital blowout fractures reconstructed with autogenous bone grafts: functional and aesthetic outcomes.
    Kronig SA; van der Mooren RJ; Strabbing EM; Stam LH; Tan JA; de Jongh E; van der Wal KG; Paridaens D; Koudstaal MJ
    Int J Oral Maxillofac Surg; 2016 Apr; 45(4):507-12. PubMed ID: 26711249
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Outcomes of Orbital Blow-Out Fracture Repair Performed Beyond 6 Weeks After Injury.
    Scawn RL; Lim LH; Whipple KM; Dolmetsch A; Priel A; Korn B; Kikkawa DO
    Ophthalmic Plast Reconstr Surg; 2016; 32(4):296-301. PubMed ID: 26275096
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A New Option for the Reconstruction of Orbital Floor Defects: The Olecranon Bone Graft.
    Yeşiloğlu N; Şirinoğlu H; Sarici M; Temiz G; Filinte GT
    Ann Plast Surg; 2015 Oct; 75(4):401-6. PubMed ID: 24691341
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Late correction of orbital-zygomatic-maxillary fractures combined with orbital wall fractures.
    Lu W; Zhou H; Xiao C; Shen Q; Lin M; Fan X
    J Craniofac Surg; 2012 Nov; 23(6):1672-6. PubMed ID: 23147315
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Medial Orbital Wall Reconstruction With Porous Polyethylene by Using a Transconjunctival Approach With a Caruncular Extension.
    Chou C; Kuo YR; Chen CC; Lai CS; Lin SD; Huang SH; Lee SS
    Ann Plast Surg; 2017 Mar; 78(3 Suppl 2):S89-S94. PubMed ID: 28195890
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wraparound nylon foil implant for isolated orbital floor fractures.
    Campbell BC; Shipchandler TZ; Ting JYM; Vernon D; Torabi RS; Miller M; Lee HBH
    Am J Otolaryngol; 2022; 43(1):103229. PubMed ID: 34537506
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.