  • 1. Reliability of intraventricular pressure measurement with fiberoptic or solid-state transducers: avoidance of a methodological error.
    Raabe A; Stöckel R; Hohrein D; Schöche J
    Neurosurgery; 1998 Jan; 42(1):74-9; discussion 79-80. PubMed ID: 9442506
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An avoidable methodological failure in intracranial pressure monitoring using fiberoptic or solid state devices.
    Raabe A; Stöckel R; Hohrein D; Schöche J
    Acta Neurochir Suppl; 1998; 71():59-61. PubMed ID: 9779145
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hollow mandrin facilitates external ventricular drainage placement.
    Heese O; Regelsberger J; Kehler U; Westphal M
    Acta Neurochir (Wien); 2005 Jul; 147(7):759-62; discussion 762. PubMed ID: 15739037
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Erroneous intracranial pressure measurements from simultaneous pressure monitoring and ventricular drainage catheters.
    Birch AA; Eynon CA; Schley D
    Neurocrit Care; 2006; 5(1):51-4. PubMed ID: 16960297
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automated intracranial pressure-controlled cerebrospinal fluid external drainage with LiquoGuard.
    Linsler S; Schmidtke M; Steudel WI; Kiefer M; Oertel J
    Acta Neurochir (Wien); 2013 Aug; 155(8):1589-94; discussion 1594-5. PubMed ID: 23188469
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pressure-controlled drainage of cerebrospinal fluid: clinical experience with a new type of ventricular catheter (Ventcontrol MTC)and an integrated Piezo-resistive sensor at its tip: technical note.
    Piek J; Raes P
    Neurosurgery; 1996 Jan; 38(1):216-8. PubMed ID: 8747976
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An evaluation and comparison of intraventricular, intraparenchymal, and fluid-coupled techniques for intracranial pressure monitoring in patients with severe traumatic brain injury.
    Vender J; Waller J; Dhandapani K; McDonnell D
    J Clin Monit Comput; 2011 Aug; 25(4):231-6. PubMed ID: 21938526
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical comparison of the Spiegelberg parenchymal transducer and ventricular fluid pressure.
    Chambers IR; Siddique MS; Banister K; Mendelow AD
    J Neurol Neurosurg Psychiatry; 2001 Sep; 71(3):383-5. PubMed ID: 11511715
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intracranial pressure monitoring using a newly developed transducer-tipped ventricular drainage catheter.
    Kasai K; Samejima H; Ueda M; Ushikubo Y; Yanai H; Kukita C; Kato T
    Neurol Med Chir (Tokyo); 1998 Apr; 38(4):238-40. PubMed ID: 9631640
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Epidural intracranial pressure measurement in rats using a fiber-optic pressure transducer.
    Murtha L; McLeod D; Spratt N
    J Vis Exp; 2012 Apr; (62):. PubMed ID: 22565931
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cerebrospinal fluid pressure measurement in the ovine intrathecal space: a preliminary study towards the diagnosis of intrathecal drug administration catheter dislodgement or occlusion.
    Coffey RJ; Miesel K; Billstrom T
    Stereotact Funct Neurosurg; 2010; 88(6):337-44. PubMed ID: 20733347
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective study of zero drift in fiberoptic pressure monitors used in clinical practice.
    Bavetta S; Norris JS; Wyatt M; Sutcliffe JC; Hamlyn PJ
    J Neurosurg; 1997 Jun; 86(6):927-30. PubMed ID: 9171170
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of fiber-optic pressure transducer for intracranial pressure measurements: a preliminary report.
    Hollingsworth-Fridlund P; Vos H; Daily EK
    Heart Lung; 1988 Mar; 17(2):111-20. PubMed ID: 3350679
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intracranial pressure monitoring techniques.
    Ghajar J
    New Horiz; 1995 Aug; 3(3):395-9. PubMed ID: 7496747
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intracranial pressure monitoring: fiberoptic monitor compared with the ventricular catheter.
    Schickner DJ; Young RF
    Surg Neurol; 1992 Apr; 37(4):251-4. PubMed ID: 1595034
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrasound stylet for non-image-guided ventricular catheterization.
    Coulson NK; Chiarelli PA; Su DK; Chang JJ; MacConaghy B; Murthy R; Toms P; Robb TL; Ellenbogen RG; Browd SR; Mourad PD
    J Neurosurg Pediatr; 2015 Oct; 16(4):393-401. PubMed ID: 26140670
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Safety and accuracy of bedside external ventricular drain placement.
    Kakarla UK; Kim LJ; Chang SW; Theodore N; Spetzler RF
    Neurosurgery; 2008 Jul; 63(1 Suppl 1):ONS162-6; discussion ONS166-7. PubMed ID: 18728595
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Laboratory testing of three intracranial pressure microtransducers: technical report.
    Czosnyka M; Czosnyka Z; Pickard JD
    Neurosurgery; 1996 Jan; 38(1):219-24. PubMed ID: 8747977
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Maintaining CSF drainage at external ventricular drains may help prevent catheter-related infections.
    Razmkon A; Bakhtazad A
    Acta Neurochir (Wien); 2009 Aug; 151(8):985. PubMed ID: 19377850
    [No Abstract]   [Full Text] [Related]  

  • 20. Bilateral External Ventricular Drains Increase Ventriculostomy-Associated Cerebrospinal Fluid Infection in Low Modified Graeb Score Intraventricular Hemorrhage.
    Zheng WJ; Li LM; Hu ZH; Liao W; Lin QC; Zhu YH; Lin SH
    World Neurosurg; 2018 Aug; 116():e550-e555. PubMed ID: 29772359
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.