These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 9451997)

  • 1. Mechanics of spatulated end-to-end artery-to-vein anastomoses.
    Morasch MD; Dobrin PB; Dong QS; Mrkvicka R
    Ann Vasc Surg; 1998 Jan; 12(1):55-9. PubMed ID: 9451997
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of suture technique and suture material selection on the mechanics of end-to-end and end-to-side anastomoses.
    Baumgartner N; Dobrin PB; Morasch M; Dong QS; Mrkvicka R
    J Thorac Cardiovasc Surg; 1996 May; 111(5):1063-72. PubMed ID: 8622304
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanics of end-to-end artery-to-PTFE graft anastomoses.
    Dobrin PB; Mirande R; Kang S; Dong QS; Mrkvicka R
    Ann Vasc Surg; 1998 Jul; 12(4):317-23. PubMed ID: 9676927
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Compliance of vascular anastomoses with polybutester and polypropylene sutures.
    Megerman J; Hamilton G; Schmitz-Rixen T; Abbott WM
    J Vasc Surg; 1993 Nov; 18(5):827-34. PubMed ID: 8230570
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Growth of the aortic anastomosis in puppies--comparison of monofilament suture materials, whether absorbable or nonabsorbable, and of suture techniques, whether continuous or interrupted].
    Nakashima S; Sugimoto H; Inoue M; Karashima S; Onitsuka T; Koga Y
    Nihon Geka Gakkai Zasshi; 1991 Feb; 92(2):206-13. PubMed ID: 1903833
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Polydioxanone and polypropylene suture material in free internal mammary artery graft anastomoses.
    Aarnio P; Harjula A; Lehtola A; Sariola H; Mattila S
    J Thorac Cardiovasc Surg; 1988 Nov; 96(5):741-5. PubMed ID: 3141723
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Absorbable polydioxanone suture for venous anastomoses: experimental studies using venography and transluminal angioscopy.
    Torsello G; Schwartz A; Aulich A; Sandmann W
    Eur J Vasc Surg; 1987 Oct; 1(5):319-25. PubMed ID: 3139460
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Vascular anastomoses of small caliber vessels. Comparison between continuous or interrupted sutures].
    Laskar M; Cornu E; Leman A; Amat P; Christides C
    Presse Med; 1988 Jun; 17(22):1152-3. PubMed ID: 2969537
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of para-anastomotic compliance profiles after vascular anastomosis: nonpenetrating clips versus standard sutures.
    Baguneid MS; Goldner S; Fulford PE; Hamilton G; Walker MG; Seifalian AM
    J Vasc Surg; 2001 Apr; 33(4):812-20. PubMed ID: 11296337
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Unique performance characteristics of Novafil.
    Rodeheaver GT; Borzelleca DC; Thacker JG; Edlich RF
    Surg Gynecol Obstet; 1987 Mar; 164(3):230-6. PubMed ID: 3547720
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Absorbable suture improves growth of venous anastomoses.
    Gillinov AM; Lee AW; Redmond JM; Zehr KJ; Jackson L; Davis EA; Hruban RH; Williams GM; Cameron DE
    J Vasc Surg; 1992 Nov; 16(5):769-73. PubMed ID: 1433665
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Growth of tracheal anastomoses in growing animals].
    Togo T; Osaka K; Yaginuma G; Mohri H; Tsuboi H; McKeown PP
    Kyobu Geka; 1989 May; 42(5):374-7. PubMed ID: 2506390
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Primary vascular anastomosis in growing pigs: comparison of polypropylene and polyglycolic acid sutures.
    Pae WE; Waldhausen JA; Prophet GA; Pierce WS
    J Thorac Cardiovasc Surg; 1981 Jun; 81(6):921-7. PubMed ID: 6262579
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental and early clinical evaluation of vascular anastomoses with argon laser fusion and the use of absorbable guy sutures: a preliminary report.
    White RA; Kopchok GE; Vlasak J; Hsiang Y; Fujitani RM; White GH; Peng SK
    J Vasc Surg; 1990 Oct; 12(4):401-6; discussion 406-8. PubMed ID: 2214036
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interrupted nitinol U-Clips versus standard running suture for the central arterial T-graft anastomosis: a prospective randomized study.
    Bigdeli AK; Kaczmarek I; Eifert S; Beiras-Fernandez A; Kober S; Nikolaou K; Oberhoffer M; Vicol C
    Eur J Cardiothorac Surg; 2011 Aug; 40(2):e93-7. PubMed ID: 21530292
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial Resistance of Carina Anastomoses with Increasing Tensile Stress: An ex vivo Model Comparing Different Suture Techniques.
    Kirschbaum A; Hemmerling S; Steinfeldt T; Bartsch DK; Mirow N
    Eur Surg Res; 2017; 58(1-2):20-26. PubMed ID: 27577554
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Argon laser-welded bovine heterograft anastomoses.
    Mueller MP; Kopchok GE; Tabbara MR; Cavaye DM; White RA
    J Clin Laser Med Surg; 1993 Feb; 11(1):1-5. PubMed ID: 10148535
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Presence of calcium in the vessel walls after end-to-end arterial anastomoses with polydioxanone and polypropylene sutures in growing dogs.
    Gersak B
    J Thorac Cardiovasc Surg; 1993 Oct; 106(4):587-91. PubMed ID: 8412250
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microvascular anastomoses in growing vessels: a long-term evaluation of nonabsorbable suture materials.
    Chen LE; Seaber AV; Urbaniak JR
    J Reconstr Microsurg; 1993 May; 9(3):183-9. PubMed ID: 8515396
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Animal model to compare the effects of suture technique on cross-sectional compliance on end-to-side anastomoses.
    Tozzi P; Hayoz D; Ruchat P; Corno A; Oedman C; Botta U; von Segesser LK
    Eur J Cardiothorac Surg; 2001 Apr; 19(4):477-81. PubMed ID: 11306316
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.