These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 9453089)

  • 1. Calibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies.
    Buis AW; Convery P
    Prosthet Orthot Int; 1997 Dec; 21(3):179-82. PubMed ID: 9453089
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee.
    Convery P; Buis AW
    Prosthet Orthot Int; 1998 Dec; 22(3):193-8. PubMed ID: 9881607
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket.
    Convery P; Buis AW
    Prosthet Orthot Int; 1999 Aug; 23(2):107-12. PubMed ID: 10493137
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Laboratory and clinical tests of a prototype pressure sensor for clincial assessment of prosthetic socket fit.
    Polliack AA; Craig DD; Sieh RC; Landsberger S; Mcneal DR
    Prosthet Orthot Int; 2002 Apr; 26(1):23-34. PubMed ID: 12043923
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.
    Hong JH; Mun MS
    Prosthet Orthot Int; 2005 Apr; 29(1):59-72. PubMed ID: 16180378
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A photoelastic clinical study of the static load distribution at the stump/socket interface of PTB sockets.
    Sewell P; Vinney J; Noroozi S; Amali R; Andrews S
    Prosthet Orthot Int; 2005 Dec; 29(3):291-302. PubMed ID: 16466158
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
    Lee VS; Solomonidis SE; Spence WD
    Proc Inst Mech Eng H; 1997; 211(2):167-80. PubMed ID: 9184457
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CIR sand casting system for trans-tibial socket.
    Wu Y; Casanova H; Smith WK; Edwards M; Childress DS
    Prosthet Orthot Int; 2003 Aug; 27(2):146-52. PubMed ID: 14571945
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound study of the motion of the residual femur within a trans-femoral socket during gait.
    Convery P; Murray KD
    Prosthet Orthot Int; 2000 Dec; 24(3):226-32. PubMed ID: 11195358
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of trans-tibial amputee suction and vacuum socket conditions.
    Board WJ; Street GM; Caspers C
    Prosthet Orthot Int; 2001 Dec; 25(3):202-9. PubMed ID: 11860094
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The capability of fiber Bragg grating sensors to measure amputees' trans-tibial stump/socket interface pressures.
    Al-Fakih EA; Osman NA; Eshraghi A; Adikan FR
    Sensors (Basel); 2013 Aug; 13(8):10348-57. PubMed ID: 23941909
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets.
    Beil TL; Street GM; Covey SJ
    J Rehabil Res Dev; 2002; 39(6):693-700. PubMed ID: 17943671
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force.
    Hall RS; Desmoulin GT; Milner TE
    J Biomech; 2008 Dec; 41(16):3492-5. PubMed ID: 19019374
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gait, cost and time implications for changing from PTB to ICEX sockets.
    Datta D; Harris I; Heller B; Howitt J; Martin R
    Prosthet Orthot Int; 2004 Aug; 28(2):115-20. PubMed ID: 15382805
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative method to measure the relationship between prosthetic gait and the forces produced at the stump-socket interface.
    Leavitt LA; Peterson CR; Canzoneri J; Paz R; Muilenburg AL; Rhyne VT
    Am J Phys Med; 1970 Jun; 49(3):192-203. PubMed ID: 5421658
    [No Abstract]   [Full Text] [Related]  

  • 16. Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot.
    Wolf SI; Alimusaj M; Fradet L; Siegel J; Braatz F
    Clin Biomech (Bristol, Avon); 2009 Dec; 24(10):860-5. PubMed ID: 19744755
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Triaxial force transducer for investigating stresses at the stump/socket interface.
    Williams RB; Porter D; Roberts VC; Regan JF
    Med Biol Eng Comput; 1992 Jan; 30(1):89-96. PubMed ID: 1640761
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interface pressures and shear stresses: sagittal plane angular alignment effects in three trans-tibial amputee case studies.
    Sanders JE; Daly CH
    Prosthet Orthot Int; 1999 Apr; 23(1):21-9. PubMed ID: 10355640
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Amputation and prosthesis fitting in paediatric patients.
    Griffet J
    Orthop Traumatol Surg Res; 2016 Feb; 102(1 Suppl):S161-75. PubMed ID: 26797004
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket.
    Lee WC; Zhang M; Jia X; Cheung JT
    Med Eng Phys; 2004 Oct; 26(8):655-62. PubMed ID: 15471693
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.