These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
108 related articles for article (PubMed ID: 9453089)
21. Static and dynamic pressure prediction for prosthetic socket fitting assessment utilising an inverse problem approach. Sewell P; Noroozi S; Vinney J; Amali R; Andrews S Artif Intell Med; 2012 Jan; 54(1):29-41. PubMed ID: 21963113 [TBL] [Abstract][Full Text] [Related]
22. Effects of fluid insert volume changes on socket pressures and shear stresses: case studies from two trans-tibial amputee subjects. Sanders JE; Jacobsen AK; Fergason JR Prosthet Orthot Int; 2006 Dec; 30(3):257-69. PubMed ID: 17162516 [TBL] [Abstract][Full Text] [Related]
23. Relaxed versus activated stump muscles during casting for trans-tibial prostheses. Lilja M; Johansson S; Oberg T Prosthet Orthot Int; 1999 Apr; 23(1):13-20. PubMed ID: 10355639 [TBL] [Abstract][Full Text] [Related]
24. The calibration of ultrasound transducers used to monitor motion of the residual femur within a trans-femoral socket during gait. Murray KD; Convery P Prosthet Orthot Int; 2000 Apr; 24(1):55-62. PubMed ID: 10855439 [TBL] [Abstract][Full Text] [Related]
25. Exploring the Use of Non-Image-Based Ultrasound to Detect the Position of the Residual Femur within a Stump. Chong SY; Röhrle O PLoS One; 2016; 11(10):e0164583. PubMed ID: 27764120 [TBL] [Abstract][Full Text] [Related]
26. Pilot study: data-capturing consistency of two trans-tibial casting concepts, using a manikin stump model: a comparison between the hands-on PTB and hands-off ICECAST compact concepts. Buis AW; Blair A; Convery P; Sockalingam S; McHugh B Prosthet Orthot Int; 2003 Aug; 27(2):100-6. PubMed ID: 14571939 [TBL] [Abstract][Full Text] [Related]
27. Dynamic alignment of transtibial prostheses through visualization of socket reaction moments. Kobayashi T; Orendurff MS; Boone DA Prosthet Orthot Int; 2015 Dec; 39(6):512-6. PubMed ID: 25121726 [TBL] [Abstract][Full Text] [Related]
28. Remote monitoring of lower-limb prosthetic socket fit using wireless technologies. Sahandi R; Sewell P; Noroozi S; Hewitt M J Med Eng Technol; 2012 Jan; 36(1):50-6. PubMed ID: 22129089 [TBL] [Abstract][Full Text] [Related]
29. Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses. Boone DA; Kobayashi T; Chou TG; Arabian AK; Coleman KL; Orendurff MS; Zhang M Gait Posture; 2013 Apr; 37(4):620-6. PubMed ID: 23177920 [TBL] [Abstract][Full Text] [Related]
30. Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses. Baars EC; Geertzen JH Prosthet Orthot Int; 2005 Apr; 29(1):27-37. PubMed ID: 16180375 [TBL] [Abstract][Full Text] [Related]
31. Design of lower limb prosthesis with contact pressure adjustment by MR fluid. Ogawa A; Obinata G; Hase K; Dutta A; Nakagawa M Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():330-3. PubMed ID: 19162660 [TBL] [Abstract][Full Text] [Related]
32. Hanging stump prosthesis without socket for bad above-knee stumps. Chand N; Srivastava RK; Maish AR Prosthet Orthot Int; 1985 Dec; 9(3):154-6. PubMed ID: 4088844 [TBL] [Abstract][Full Text] [Related]
33. Evaluation of force-sensing resistors for gait event detection to trigger electrical stimulation to improve walking in the child with cerebral palsy. Smith BT; Coiro DJ; Finson R; Betz RR; McCarthy J IEEE Trans Neural Syst Rehabil Eng; 2002 Mar; 10(1):22-9. PubMed ID: 12173736 [TBL] [Abstract][Full Text] [Related]
34. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting. Portnoy S; Yarnitzky G; Yizhar Z; Kristal A; Oppenheim U; Siev-Ner I; Gefen A Ann Biomed Eng; 2007 Jan; 35(1):120-35. PubMed ID: 17120139 [TBL] [Abstract][Full Text] [Related]
35. Ultrasound study of the motion of the residual femur within a trans-femoral socket during daily living activities other than gait. Convery P; Murray KD Prosthet Orthot Int; 2001 Dec; 25(3):220-7. PubMed ID: 11860096 [TBL] [Abstract][Full Text] [Related]
36. CAD/CAM evaluation of the fit of trans-tibial sockets for trans-tibial amputation stumps. Isozaki K; Hosoda M; Masuda T; Morita S J Med Dent Sci; 2006 Mar; 53(1):51-6. PubMed ID: 16722145 [TBL] [Abstract][Full Text] [Related]
37. Suspension effect and dynamic evaluation of the total surface bearing (TSB) trans-tibial prosthesis: a comparison with the patellar tendon bearing (PTB) trans-tibial prosthesis. Narita H; Yokogushi K; Shii S; Kakizawa M; Nosaka T Prosthet Orthot Int; 1997 Dec; 21(3):175-8. PubMed ID: 9453088 [TBL] [Abstract][Full Text] [Related]
38. Plantar foot pressure responses to changes during dynamic trans-tibial prosthetic alignment in a clinical setting. Geil MD; Lay A Prosthet Orthot Int; 2004 Aug; 28(2):105-14. PubMed ID: 15382804 [TBL] [Abstract][Full Text] [Related]
39. Ultrasound imaging in lower limb prosthetics. Douglas T; Solomonidis S; Sandham W; Spence W IEEE Trans Neural Syst Rehabil Eng; 2002 Mar; 10(1):11-21. PubMed ID: 12173735 [TBL] [Abstract][Full Text] [Related]
40. Morphological changes during early trans-tibial prosthetic fitting. Lilja M; Hoffmann P; Oberg T Prosthet Orthot Int; 1998 Aug; 22(2):115-22. PubMed ID: 9747995 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]