These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 9456387)

  • 1. Cement-mantle thickness affects cement strains in total hip replacement.
    Fisher DA; Tsang AC; Paydar N; Milionis S; Turner CH
    J Biomech; 1997; 30(11-12):1173-7. PubMed ID: 9456387
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Factors affecting cement strains near the tip of a cemented femoral component.
    Estok DM; Orr TE; Harris WH
    J Arthroplasty; 1997 Jan; 12(1):40-8. PubMed ID: 9021500
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing.
    O'Connor DO; Burke DW; Jasty M; Sedlacek RC; Harris WH
    J Orthop Res; 1996 Sep; 14(5):769-77. PubMed ID: 8893771
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of femoral neck length, stem size, and body weight on strains in the proximal cement mantle.
    Harrington MA; O'Connor DO; Lozynsky AJ; Kovach I; Harris WH
    J Bone Joint Surg Am; 2002 Apr; 84(4):573-9. PubMed ID: 11940617
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of stem geometry on mechanics of cemented femoral hip components with a proximal bond.
    Mann KA; Bartel DL; Ayers DC
    J Orthop Res; 1997 Sep; 15(5):700-6. PubMed ID: 9420599
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses.
    Ramos A; Simões JA
    J Biomech; 2009 Nov; 42(15):2602-10. PubMed ID: 19660758
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of dorsal flanges on fixation of a cemented total hip replacement femoral stem.
    Sangiorgio SN; Ebramzadeh E; Longjohn DB; Dorr LD
    J Bone Joint Surg Am; 2004 Apr; 86(4):813-20. PubMed ID: 15069149
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Femoral component loosening in hip arthroplasty. Cadaver study of subsidence and hoop strain.
    Manley MT; Stern LS; Kotzar G; Stulberg BN
    Acta Orthop Scand; 1987 Oct; 58(5):485-90. PubMed ID: 3425274
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface.
    Ramaniraka NA; Rakotomanana LR; Leyvraz PF
    J Bone Joint Surg Br; 2000 Mar; 82(2):297-303. PubMed ID: 10755444
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sensitivity analysis of a cemented hip stem to implant position and cement mantle thickness.
    Shi J; Browne M; Strickland M; Flivik G; Taylor M
    Comput Methods Biomech Biomed Engin; 2014 Nov; 17(15):1671-84. PubMed ID: 23405986
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Femoral component offset. Its effect on strain in bone-cement.
    Davey JR; O'Connor DO; Burke DW; Harris WH
    J Arthroplasty; 1993 Feb; 8(1):23-6. PubMed ID: 8436985
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components.
    Harrigan TP; Harris WH
    J Biomech; 1991; 24(11):1047-58. PubMed ID: 1761581
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of distal cement voids on cement stress in total hip arthroplasty.
    Powers CM; Lee IY; Skinner HB; Keyak JH
    J Arthroplasty; 1998 Oct; 13(7):793-8. PubMed ID: 9802667
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In-vitro characteristics of cemented titanium femoral stems with a smooth surface finish.
    Akiyama H; Yamamoto K; Kaneuji A; Matsumoto T; Nakamura T
    J Orthop Sci; 2013 Jan; 18(1):29-37. PubMed ID: 22945910
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization.
    Star MJ; Colwell CW; Kelman GJ; Ballock RT; Walker RH
    J Arthroplasty; 1994 Apr; 9(2):143-9. PubMed ID: 8014645
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant.
    Lee IY; Skinner HB; Keyak JH
    Iowa Orthop J; 1993; 13():155-9. PubMed ID: 7820736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modelling the fibrous tissue layer in cemented hip replacements: experimental and finite element methods.
    Waide V; Cristofolini L; Stolk J; Verdonschot N; Boogaard GJ; Toni A
    J Biomech; 2004 Jan; 37(1):13-26. PubMed ID: 14672564
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases.
    Woolson ST; Milbauer JP; Bobyn JD; Yue S; Maloney WJ
    J Bone Joint Surg Am; 1997 Dec; 79(12):1842-8. PubMed ID: 9409798
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The relationship between cement fatigue damage and implant surface finish in proximal femoral prostheses.
    Lennon AB; McCormack BA; Prendergast PJ
    Med Eng Phys; 2003 Dec; 25(10):833-41. PubMed ID: 14630471
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.