These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 9463958)

  • 1. Supported liquid membrane enrichment combined with atomic absorption spectrometry for the determination of lead in urine.
    Djane NK; Bergdahl IA; Ndung'u K; Schütz A; Johansson G; Mathiasson L
    Analyst; 1997 Oct; 122(10):1073-7. PubMed ID: 9463958
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Supported liquid membrane coupled on-line to potentiometric stripping analysis at a mercury-coated reticulated vitreous carbon electrode for trace metal determinations in urine.
    Djane NK; Armalis S; Ndung'u K; Johansson G; Mathiasson L
    Analyst; 1998 Feb; 123(2):393-6. PubMed ID: 9579090
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of lead in urine by electrothermal atomic absorption spectrometry with probe atomization.
    Chen T; Littlejohn D
    Analyst; 1993 May; 118(5):541-3. PubMed ID: 8323046
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Membrane supported liquid-liquid-liquid microextraction combined with field-amplified sample injection CE-UV for high-sensitivity analysis of six cardiovascular drugs in human urine sample.
    Zhou X; He M; Chen B; Yang Q; Hu B
    Electrophoresis; 2016 May; 37(9):1201-11. PubMed ID: 26763094
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrophotometry for the determination of trace elements in blood and urine from non occupationally exposed populations.
    White MA
    J Trace Elem Med Biol; 1999 Jul; 13(1-2):93-101. PubMed ID: 10445225
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Complexation-mediated electromembrane extraction of highly polar basic drugs-a fundamental study with catecholamines in urine as model system.
    Fernández E; Vårdal L; Vidal L; Canals A; Gjelstad A; Pedersen-Bjergaard S
    Anal Bioanal Chem; 2017 Jul; 409(17):4215-4223. PubMed ID: 28451718
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of a novel medium, the ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate, for liquid-liquid extraction of lead in water and its determination by graphite furnace atomic absorption spectrometry.
    Zaijun L; Qiping P; Haixia S
    J AOAC Int; 2007; 90(4):1191-6. PubMed ID: 17760357
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic On-line Solid-phase Extraction-Electrothermal Atomic Absorption Spectrometry Exploiting Sequential Injection Analysis for Trace Vanadium, Cadmium and Lead Determination in Human Urine Samples.
    Giakisikli G; Ayala Quezada A; Tanaka J; Anthemidis AN; Murakami H; Teshima N; Sakai T
    Anal Sci; 2015; 31(5):383-9. PubMed ID: 25958867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet/inductively coupled plasma mass spectrometry for analysis of thyroxine in urine samples.
    Fan W; Mao X; He M; Chen B; Hu B
    J Chromatogr A; 2013 Nov; 1318():49-57. PubMed ID: 24354001
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry: ultra trace determination of cadmium in water samples.
    Zeini Jahromi E; Bidari A; Assadi Y; Milani Hosseini MR; Jamali MR
    Anal Chim Acta; 2007 Mar; 585(2):305-11. PubMed ID: 17386679
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Synthesis and characterization of a novel mesoporous silica functionalized with [1,5 bis(di-2-pyridyl)methylene thiocarbohydrazide] and its application as enrichment sorbent for determination of antimony by FI-HG-ETAAS.
    López Guerrero MM; Siles Cordero MT; Vereda Alonso E; García de Torres A; Cano Pavón JM
    Talanta; 2014 Nov; 129():1-8. PubMed ID: 25127557
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of a macrocycle immobilized silica gel sorbent to flow injection on-line microcolumn preconcentration and separation coupled with flame atomic absorption spectrometry for interference-free determination of trace lead in biological and environmental samples.
    Yan XP; Sperling M; Welz B
    Anal Chem; 1999 Oct; 71(19):4216-22. PubMed ID: 10660437
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid analysis of nickel in urine by electrothermal atomic absorption spectrophotometry.
    Sunderman FW; Hopfer SM; Crisostomo MC; Stoeppler M
    Ann Clin Lab Sci; 1986; 16(3):219-30. PubMed ID: 3717884
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid determination of lead in water samples by dispersive liquid-liquid microextraction coupled with electrothermal atomic absorption spectrometry.
    Naseri MT; Hosseini MR; Assadi Y; Kiani A
    Talanta; 2008 Mar; 75(1):56-62. PubMed ID: 18371847
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of trace lead in biological and water samples with dispersive liquid-liquid microextraction preconcentration.
    Liang P; Sang H
    Anal Biochem; 2008 Sep; 380(1):21-5. PubMed ID: 18539126
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In situ emulsification microextraction using a dicationic ionic liquid followed by magnetic assisted physisorption for determination of lead prior to micro-sampling flame atomic absorption spectrometry.
    Shokri M; Beiraghi A; Seidi S
    Anal Chim Acta; 2015 Aug; 889():123-9. PubMed ID: 26343434
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrasonic energy as a tool to overcome some drawbacks in the determination of lead in brain tissue and urine of rats.
    Guimarães D; Santos JP; Carvalho ML; Vale G; Santos HM; Geraldes V; Rocha I; Capelo JL
    Talanta; 2011 Oct; 86():442-6. PubMed ID: 22063564
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sample preparation for arsenic speciation in terrestrial plants--a review.
    Amaral CD; Nóbrega JA; Nogueira AR
    Talanta; 2013 Oct; 115():291-9. PubMed ID: 24054594
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Direct determination of lead in urine with a new micro-method of flame atomic absorption spectroscopy (loop-AAS) (author's transl)].
    Berndt H; Gücer S; Messerschmidt J
    J Clin Chem Clin Biochem; 1982 Feb; 20(2):85-90. PubMed ID: 7069384
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Trace determination of lead, chromium and cadmium in herbal medicines using ultrasound-assisted emulsification microextraction combined with graphite furnace atomic absorption spectrometry.
    Aghamohammadi M; Faraji M; Shahdousti P; Kalhor H; Saleh A
    Phytochem Anal; 2015; 26(3):209-14. PubMed ID: 25573256
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.