These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 9465217)

  • 1. [The validation of stereolithographic anatomical replicas: the authors' own experience and a review of the literature].
    Bianchi SD; Ramieri G; De Gioanni PP; Martinetto F; Berrone S
    Radiol Med; 1997 Nov; 94(5):503-10. PubMed ID: 9465217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stereolithographic models derived from x-ray computed tomography. Reproduction accuracy.
    Bouyssié JF; Bouyssié S; Sharrock P; Duran D
    Surg Radiol Anat; 1997; 19(3):193-9. PubMed ID: 9381322
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapid prototyping to create vascular replicas from CT scan data: making tools to teach, rehearse, and choose treatment strategies.
    Knox K; Kerber CW; Singel SA; Bailey MJ; Imbesi SG
    Catheter Cardiovasc Interv; 2005 May; 65(1):47-53. PubMed ID: 15800891
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of stereolithographic models of human anatomy.
    Barker TM; Earwaker WJ; Lisle DA
    Australas Radiol; 1994 May; 38(2):106-11. PubMed ID: 8024501
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-dimensional printing to facilitate anatomic study, device development, simulation, and planning in thoracic surgery.
    Kurenov SN; Ionita C; Sammons D; Demmy TL
    J Thorac Cardiovasc Surg; 2015 Apr; 149(4):973-9.e1. PubMed ID: 25659851
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The reproduction accuracy for stereolithographic model of the thyroid gland derived from the visible human dataset.
    Kapakin S; Demiryurek D
    Saudi Med J; 2009 Jul; 30(7):887-92. PubMed ID: 19618001
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of virtual reality and stereolithographic models in maxillo-facial surgical planning.
    Robiony M; Salvo I; Costa F; Zerman N; Bandera C; Filippi S; Felice M; Politi M
    J Craniofac Surg; 2008 Mar; 19(2):482-9. PubMed ID: 18362729
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stereolithographic biomodelling to create tangible hard copies of the ethmoidal labyrinth air cells based on the visible human project.
    Kapakin S
    Folia Morphol (Warsz); 2011 Feb; 70(1):33-40. PubMed ID: 21604251
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of two computer-assisted surgery techniques to guide a mandibular distraction osteogenesis procedure. Technical note.
    d'Hauthuille C; Taha F; Devauchelle B; Testelin S
    Int J Oral Maxillofac Surg; 2005 Mar; 34(2):197-201. PubMed ID: 15695051
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Parametric Model of the Human Mandible Coronoid Process Created by Method of Anatomical Features.
    Vitković N; Mitić J; Manić M; Trajanović M; Husain K; Petrović S; Arsić S
    Comput Math Methods Med; 2015; 2015():574132. PubMed ID: 26064183
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stereolithographic models for surgical planning in congenital heart surgery.
    Sodian R; Weber S; Markert M; Rassoulian D; Kaczmarek I; Lueth TC; Reichart B; Daebritz S
    Ann Thorac Surg; 2007 May; 83(5):1854-7. PubMed ID: 17462413
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design and fabrication of custom mandible titanium tray based on rapid prototyping.
    Singare S; Dichen L; Bingheng L; Yanpu L; Zhenyu G; Yaxiong L
    Med Eng Phys; 2004 Oct; 26(8):671-6. PubMed ID: 15471695
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cerebrovascular stereolithographic biomodeling for aneurysm surgery. Technical note.
    Wurm G; Tomancok B; Pogady P; Holl K; Trenkler J
    J Neurosurg; 2004 Jan; 100(1):139-45. PubMed ID: 14743927
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs.
    Brzobohatá H; Prokop J; Horák M; Jancárek A; Velemínská J
    Coll Antropol; 2012 Sep; 36(3):801-6. PubMed ID: 23213936
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.
    Ersoy AE; Turkyilmaz I; Ozan O; McGlumphy EA
    J Periodontol; 2008 Aug; 79(8):1339-45. PubMed ID: 18672982
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of three-dimensional, paper-based models generated using a low-cost, three-dimensional printer.
    Olszewski R; Szymor P; Kozakiewicz M
    J Craniomaxillofac Surg; 2014 Dec; 42(8):1847-52. PubMed ID: 25176496
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Integration of 3-D medical imaging and rapid prototyping to create stereolithographic models.
    Barker TM; Earwaker WJ; Frost N; Wakeley G
    Australas Phys Eng Sci Med; 1993 Jun; 16(2):79-85. PubMed ID: 8357307
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of mandibular genioplasty using a stereolithographic surgical guide: in vitro comparison with a manual measurement method based on preoperative surgical simulation.
    Kang SH; Lee JW; Lim SH; Kim YH; Kim MK
    J Oral Maxillofac Surg; 2014 Oct; 72(10):2032-42. PubMed ID: 24780609
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques.
    Hazeveld A; Huddleston Slater JJ; Ren Y
    Am J Orthod Dentofacial Orthop; 2014 Jan; 145(1):108-15. PubMed ID: 24373661
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Technique and applications of stereolithographic cranial models].
    Wolf HP; Lindner A; Millesi W; Knabl J; Watzke I
    Fortschr Kiefer Gesichtschir; 1994; 39():19-22. PubMed ID: 8088661
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.