437 related articles for article (PubMed ID: 9466504)
1. Direct determination of blood recirculation rate in hemodialysis by a conductivity method.
Bosc JY; LeBlanc M; Garred LJ; Marc JM; Foret M; Babinet F; Tetta C; Canaud B
ASAIO J; 1998; 44(1):68-73. PubMed ID: 9466504
[TBL] [Abstract][Full Text] [Related]
2. A comparison of methods for the measurement of hemodialysis access recirculation and access blood flow rate.
Lindsay RM; Bradfield E; Rothera C; Kianfar C; Malek P; Blake PG
ASAIO J; 1998; 44(1):62-7. PubMed ID: 9466503
[TBL] [Abstract][Full Text] [Related]
3. Blood recirculation in temporary central catheters for acute hemodialysis.
Leblanc M; Fedak S; Mokris G; Paganini EP
Clin Nephrol; 1996 May; 45(5):315-9. PubMed ID: 8738663
[TBL] [Abstract][Full Text] [Related]
4. Hemodialysis blood access flow rates can be estimated accurately from on-line dialysate urea measurements and the knowledge of effective dialyzer urea clearance.
Lindsay RM; Sternby J; Olde B; Persson R; Thatcher ME; Sargent K
Clin J Am Soc Nephrol; 2006 Sep; 1(5):960-4. PubMed ID: 17699313
[TBL] [Abstract][Full Text] [Related]
5. Haemodialysis with on-line monitoring equipment: tools or toys?
Locatelli F; Buoncristiani U; Canaud B; Köhler H; Petitclerc T; Zucchelli P
Nephrol Dial Transplant; 2005 Jan; 20(1):22-33. PubMed ID: 15632348
[TBL] [Abstract][Full Text] [Related]
6. Comparison of glucose pump test and urea test in measuring blood access flow.
Alloatti S; Magnasco A; Bonfant G; Pellu V; Paroli V
J Nephrol; 2004; 17(4):559-64. PubMed ID: 15372419
[TBL] [Abstract][Full Text] [Related]
7. Relationship between effective ionic dialysance and in vivo urea clearance during hemodialysis.
Lindsay RM; Bene B; Goux N; Heidenheim AP; Landgren C; Sternby J
Am J Kidney Dis; 2001 Sep; 38(3):565-74. PubMed ID: 11532690
[TBL] [Abstract][Full Text] [Related]
8. Predicting hemodialysis access failure with the measurement of dialysis access recirculation.
Salimi J; Razeghi E; Karjalian H; Meysamie A; Dahhaz M; Dadmehr M
Saudi J Kidney Dis Transpl; 2008 Sep; 19(5):781-4. PubMed ID: 18711295
[TBL] [Abstract][Full Text] [Related]
9. [Recirculation of urea and dialysis efficiency using dual-lumen dialysis catheters in various locations: may the venous lumen of the catheter be used as the arterial lumen and vice versa?].
Sefer S; Kes P; Degoricija V; Heinrich B; Vrsalović M
Lijec Vjesn; 2003; 125(1-2):1-5. PubMed ID: 12812016
[TBL] [Abstract][Full Text] [Related]
10. A comparison of methods for the measurement of hemodialysis access recirculation.
Basile C; Ruggieri G; Vernaglione L; Montanaro A; Giordano R
J Nephrol; 2003; 16(6):908-13. PubMed ID: 14736020
[TBL] [Abstract][Full Text] [Related]
11. Vascular access recirculation in hemodialysis patients with two noncuffed, single-lumen, jugular catheters in the same jugular vein.
Kovac J; Buturović-Ponikvar J; Ponikvar R
Ther Apher Dial; 2009 Aug; 13(4):350-3. PubMed ID: 19695073
[TBL] [Abstract][Full Text] [Related]
12. Pilot study to assess increased dialysis efficiency in patients with limited blood flow rates due to vascular access problems.
Mandolfo S; Borlandelli S; Imbasciati E; Badalamenti S; Graziani G; Sereni L; Varesani M; Wratten ML; Corsi A; Elli A
Hemodial Int; 2008 Jan; 12(1):55-61. PubMed ID: 18271842
[TBL] [Abstract][Full Text] [Related]
13. All currently used measurements of recirculation in blood access by chemical methods are flawed due to intradialytic disequilibrium or recirculation at low flow.
Twardowski ZJ; Van Stone JC; Haynie JD
Am J Kidney Dis; 1998 Dec; 32(6):1046-58. PubMed ID: 9856523
[TBL] [Abstract][Full Text] [Related]
14. HCO3 increment in arterial line can reveal significant vascular access recirculation in high-flux hemodialysis: a preliminary report.
Sombolos KI; Christidou FN; Bamichas GI; Gionanlis LD; Karagianni AC; Anagnostopoulos TC; Natse TA
Hemodial Int; 2006 Jan; 10(1):88-93. PubMed ID: 16441833
[TBL] [Abstract][Full Text] [Related]
15. Peripheral venous blood is not the appropriate specimen to determine the amount of recirculation during hemodialysis.
Van Stone JC
ASAIO J; 1996; 42(1):41-5. PubMed ID: 8808457
[TBL] [Abstract][Full Text] [Related]
16. Urea concentration gradients during conventional hemodialysis.
Sombolos K; Natse T; Zoumbaridis N; Mavromatidis K; Karagianni A; Scandalos J; Fitili C
Am J Kidney Dis; 1996 May; 27(5):673-9. PubMed ID: 8629627
[TBL] [Abstract][Full Text] [Related]
17. Influence of the ionic dialysance monitor on Kt measurement in hemodialysis.
Maduell F; Vera M; Arias M; Serra N; Blasco M; Bergadá E; Fontsere N; Cases A; Campistol JM
Am J Kidney Dis; 2008 Jul; 52(1):85-92. PubMed ID: 18455852
[TBL] [Abstract][Full Text] [Related]
18. Accuracy and precision of access recirculation measurements by the hemodynamic recirculation monitor.
Lindsay RM; Blake PG; Malek P; Posen G; Martin B; Bradfield E
Am J Kidney Dis; 1998 Feb; 31(2):242-9. PubMed ID: 9469494
[TBL] [Abstract][Full Text] [Related]
19. A regional blood circulation alternative to in-series two compartment urea kinetic modeling.
Schneditz D; Van Stone JC; Daugirdas JT
ASAIO J; 1993; 39(3):M573-7. PubMed ID: 8268602
[TBL] [Abstract][Full Text] [Related]
20. Theoretical and practical issues in recirculation; assessment of vascular access.
Schneditz D
EDTNA ERCA J; 1998; 24(2):3-6. PubMed ID: 10392054
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]