These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. ["After-image perimeter (Awaya)" and its clinical application. I. Assessment of visual field in hemianopsia and quadrantanopsia (author's transl)]. Awaya S; Mano K; Miyake S; Sugawara M; Nozaki H Nippon Ganka Gakkai Zasshi; 1980 Aug; 84(8):1018-26. PubMed ID: 7211582 [No Abstract] [Full Text] [Related]
4. The Friedmann visual field analyser tested on neuro-ophthalmological cases. Bynke H; Nordenfelt L Acta Ophthalmol (Copenh); 1974; 52(6):861-71. PubMed ID: 4480333 [No Abstract] [Full Text] [Related]
5. Double point test with the Goldmann perimeter. Enoksson P; Friström B Acta Ophthalmol (Copenh); 1975 Dec; 53(6):834-8. PubMed ID: 1243230 [TBL] [Abstract][Full Text] [Related]
6. Structure-Function Correlation in Hemianopic Vision Loss in Children Aged 3-6 Years Using OCT and SVOP, and Comparison with Adult Eyes. Bowl W; Knobloch R; Schweinfurth S; Holve K; Stieger K; Lorenz B Ophthalmic Res; 2018; 60(4):221-230. PubMed ID: 29332093 [TBL] [Abstract][Full Text] [Related]
7. An evaluation of the accuracy of community-based perimetry. Trobe JD; Acosta PC; Shuster JJ; Krischer JP Am J Ophthalmol; 1980 Nov; 90(5):654-60. PubMed ID: 7446646 [TBL] [Abstract][Full Text] [Related]
8. Serial analysis of changes in visual field defects, employing a new instrument, to determine the activity of diseases involving the visual pathways. Friedmann AI Ophthalmologica; 1966; 152(1):1-12. PubMed ID: 5919996 [No Abstract] [Full Text] [Related]
9. A feasible development of computerized perimetry. Krakau CE Acta Ophthalmol (Copenh); 1981 Aug; 59(4):485-94. PubMed ID: 7315206 [TBL] [Abstract][Full Text] [Related]
10. How effective is perimetry in current practice? Trobe JD Ophthalmology; 1983 Nov; 90(11):1380-3. PubMed ID: 6664679 [TBL] [Abstract][Full Text] [Related]
11. Sectoral analysis of the retinal nerve fiber layer thinning and its association with visual field loss in homonymous hemianopia caused by post-geniculate lesions using spectral-domain optical coherence tomography. Goto K; Miki A; Yamashita T; Araki S; Takizawa G; Nakagawa M; Ieki Y; Kiryu J Graefes Arch Clin Exp Ophthalmol; 2016 Apr; 254(4):745-56. PubMed ID: 26446718 [TBL] [Abstract][Full Text] [Related]
13. Loss of stereopsis with optic chiasmal lesions and stereoscopic tests as a differential test. Hirai T; Ito Y; Arai M; Ota Y; Kojima T; Sato M; Miyake Y Ophthalmology; 2002 Sep; 109(9):1692-702. PubMed ID: 12208719 [TBL] [Abstract][Full Text] [Related]
15. Giant cell arteritis presenting with hemianopic visual field loss. Randhawa S; Van Stavern GP Can J Ophthalmol; 2007 Jun; 42(3):486-7. PubMed ID: 17508057 [No Abstract] [Full Text] [Related]
16. Does frequency doubling technology perimetry reliably detect neurological visual field defects? Fong KC; Byles DB; Constable PH Eye (Lond); 2003 Apr; 17(3):330-3. PubMed ID: 12724694 [TBL] [Abstract][Full Text] [Related]
17. [Perimetry and other function tests]. Niesel P Ophthalmologica; 1969; 158(5):433-50. PubMed ID: 5345435 [No Abstract] [Full Text] [Related]
18. A clinical comparison of visual field testing with a new automated perimeter, the Humphrey Field Analyzer, and the Goldmann perimeter. Beck RW; Bergstrom TJ; Lichter PR Ophthalmology; 1985 Jan; 92(1):77-82. PubMed ID: 3974997 [TBL] [Abstract][Full Text] [Related]
19. A binocular perimeter. Owen D Am J Ophthalmol; 1977 Jun; 83(6):918-22. PubMed ID: 868997 [TBL] [Abstract][Full Text] [Related]