254 related articles for article (PubMed ID: 9468418)
1. Diagnostic and therapeutic impact of push enteroscopy: analysis of factors associated with positive findings.
Chak A; Koehler MK; Sundaram SN; Cooper GS; Canto MI; Sivak MV
Gastrointest Endosc; 1998 Jan; 47(1):18-22. PubMed ID: 9468418
[TBL] [Abstract][Full Text] [Related]
2. Capsule endoscopy versus push enteroscopy in patients with occult gastrointestinal bleeding.
Hartmann D; Schilling D; Bolz G; Hahne M; Jakobs R; Siegel E; Weickert U; Adamek HE; Riemann JF
Z Gastroenterol; 2003 May; 41(5):377-82. PubMed ID: 12772049
[TBL] [Abstract][Full Text] [Related]
3. Use of the enteroscope for colo-ileoscopy: low yield in unexplained lower gastrointestinal bleeding.
Belaiche J; Van Kemseke C; Louis E
Endoscopy; 1999 May; 31(4):298-301. PubMed ID: 10376455
[TBL] [Abstract][Full Text] [Related]
4. Total peroral intraoperative enteroscopy for obscure GI bleeding using a dedicated push enteroscope: diagnostic yield and patient outcome.
Zaman A; Sheppard B; Katon RM
Gastrointest Endosc; 1999 Oct; 50(4):506-10. PubMed ID: 10502171
[TBL] [Abstract][Full Text] [Related]
5. Diagnostic yield and effect on clinical outcomes of push enteroscopy in suspected small-bowel bleeding.
Hayat M; Axon AT; O'Mahony S
Endoscopy; 2000 May; 32(5):369-72. PubMed ID: 10817173
[TBL] [Abstract][Full Text] [Related]
6. Clinical usefulness of the endoscopic video capsule as the initial intestinal investigation in patients with obscure digestive bleeding: validation of a diagnostic strategy based on the patient outcome after 12 months.
Delvaux M; Fassler I; Gay G
Endoscopy; 2004 Dec; 36(12):1067-73. PubMed ID: 15578296
[TBL] [Abstract][Full Text] [Related]
7. Small bowel push-type fiberoptic enteroscopy for patients with occult gastrointestinal bleeding or suspected small bowel pathology.
Chong J; Tagle M; Barkin JS; Reiner DK
Am J Gastroenterol; 1994 Dec; 89(12):2143-6. PubMed ID: 7977230
[TBL] [Abstract][Full Text] [Related]
8. Push enteroscopy in the era of capsule endoscopy.
Sidhu R; McAlindon ME; Kapur K; Hurlstone DP; Wheeldon MC; Sanders DS
J Clin Gastroenterol; 2008 Jan; 42(1):54-8. PubMed ID: 18097290
[TBL] [Abstract][Full Text] [Related]
9. Wireless capsule endoscopy in patients with obscure gastrointestinal bleeding: a comparative study with push enteroscopy.
Mata A; Bordas JM; Feu F; Ginés A; Pellisé M; Fernández-Esparrach G; Balaguer F; Piqué JM; Llach J
Aliment Pharmacol Ther; 2004 Jul; 20(2):189-94. PubMed ID: 15233699
[TBL] [Abstract][Full Text] [Related]
10. Video push enteroscopy in the investigation of small bowel disease: defining clinical indications and outcomes.
Shackel NA; Bowen DG; Selby WS
Aust N Z J Med; 1998 Apr; 28(2):198-203. PubMed ID: 9612528
[TBL] [Abstract][Full Text] [Related]
11. Prospective comparison of push enteroscopy and push-and-pull enteroscopy in patients with suspected small-bowel bleeding.
May A; Nachbar L; Schneider M; Ell C
Am J Gastroenterol; 2006 Sep; 101(9):2016-24. PubMed ID: 16968508
[TBL] [Abstract][Full Text] [Related]
12. A prospective comparative study of push and wireless-capsule enteroscopy in patients with obscure digestive bleeding.
Van Gossum A; Hittelet A; Schmit A; Francois E; Devière J
Acta Gastroenterol Belg; 2003; 66(3):199-205. PubMed ID: 14618949
[TBL] [Abstract][Full Text] [Related]
13. The rate of lesions found within reach of esophagogastroduodenoscopy during push enteroscopy depends on the type of obscure gastrointestinal bleeding.
Lara LF; Bloomfeld RS; Pineau BC
Endoscopy; 2005 Aug; 37(8):745-50. PubMed ID: 16032494
[TBL] [Abstract][Full Text] [Related]
14. A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with obscure gastrointestinal bleeding.
Triester SL; Leighton JA; Leontiadis GI; Fleischer DE; Hara AK; Heigh RI; Shiff AD; Sharma VK
Am J Gastroenterol; 2005 Nov; 100(11):2407-18. PubMed ID: 16279893
[TBL] [Abstract][Full Text] [Related]
15. Diagnostic yield and clinical implications of push enteroscopy: results from a nonspecialized center.
Linder J; Cheruvattath R; Truss C; Wilcox CM
J Clin Gastroenterol; 2002; 35(5):383-6. PubMed ID: 12394225
[TBL] [Abstract][Full Text] [Related]
16. Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding.
Mylonaki M; Fritscher-Ravens A; Swain P
Gut; 2003 Aug; 52(8):1122-6. PubMed ID: 12865269
[TBL] [Abstract][Full Text] [Related]
17. A prospective two-center study comparing wireless capsule endoscopy with intraoperative enteroscopy in patients with obscure GI bleeding.
Hartmann D; Schmidt H; Bolz G; Schilling D; Kinzel F; Eickhoff A; Huschner W; Möller K; Jakobs R; Reitzig P; Weickert U; Gellert K; Schultz H; Guenther K; Hollerbuhl H; Schoenleben K; Schulz HJ; Riemann JF
Gastrointest Endosc; 2005 Jun; 61(7):826-32. PubMed ID: 15933683
[TBL] [Abstract][Full Text] [Related]
18. Push enteroscopy for obscure gastrointestinal bleeding yields a high incidence of proximal lesions within reach of a standard endoscope.
Zaman A; Katon RM
Gastrointest Endosc; 1998 May; 47(5):372-6. PubMed ID: 9609429
[TBL] [Abstract][Full Text] [Related]
19. Actively bleeding Dieulafoy's lesion of the small bowel identified by capsule endoscopy and treated by push enteroscopy.
De Palma GD; Patrone F; Rega M; Simeoli I; Masone S; Persico G
World J Gastroenterol; 2006 Jun; 12(24):3936-7. PubMed ID: 16804987
[TBL] [Abstract][Full Text] [Related]
20. Diagnostic yield of 335 push video-enteroscopies.
Gómez Rodríguez BJ; Ortiz Moyano C; Romero Castro R; Caunedo Alvarez A; Hernández Durán MD; Hergueta Delgado P; Pellicer Bautista F; Herrerías Gutiérrez J
Rev Esp Enferm Dig; 2006 Feb; 98(2):82-92. PubMed ID: 16566640
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]