These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 9471698)

  • 1. [The electrochemical behavior of TiTa30 and TiNb30 alloys for implantology].
    Hildebrand HF; Ralison A; Traisnel M; Breme J
    Rev Stomatol Chir Maxillofac; 1997 Nov; 98 Suppl 1():56-7. PubMed ID: 9471698
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of surface area ratios and bacteria on electrochemical behavior of galvanically coupled titanium.
    Koh I; Oshida Y; Andres CJ; Gregory RL
    Int J Prosthodont; 2008; 21(5):433-6. PubMed ID: 18950067
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva.
    Bilhan H; Bilgin T; Cakir AF; Yuksel B; Von Fraunhofer JA
    J Biomater Appl; 2007 Nov; 22(3):197-221. PubMed ID: 17255155
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy.
    Grosgogeat B; Boinet M; Dalard F; Lissac M
    Biomed Mater Eng; 2004; 14(3):323-31. PubMed ID: 15299244
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications.
    Oliveira NT; Guastaldi AC
    Acta Biomater; 2009 Jan; 5(1):399-405. PubMed ID: 18707926
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrochemical impedance spectroscopy study of Ti-6Al-4V alloy in artificial saliva with fluoride and/or bovine albumin.
    Huang HH; Lee TH
    Dent Mater; 2005 Aug; 21(8):749-55. PubMed ID: 15878783
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Electrochemical properties of biocompatible material hardness modifications on titanium and steel under mechanical loads].
    Braun W; Walter U; Holbein R; Thull R
    Biomed Tech (Berl); 2005 Apr; 50(4):100-6. PubMed ID: 15884706
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro biocompatibility, mechanical properties, and corrosion resistance of Ti-Zr-Nb-Ta-Pd and Ti-Sn-Nb-Ta-Pd alloys.
    Ito A; Okazaki Y; Tateishi T; Ito Y
    J Biomed Mater Res; 1995 Jul; 29(7):893-9. PubMed ID: 7593029
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cytocompatibility and electrochemical properties of Ti-Au alloys for biomedical applications.
    Oh KT; Kang DK; Choi GS; Kim KN
    J Biomed Mater Res B Appl Biomater; 2007 Nov; 83(2):320-6. PubMed ID: 17385226
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.
    Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K
    Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corrosion resistance and in vitro response of laser-deposited Ti-Nb-Zr-Ta alloys for orthopedic implant applications.
    Samuel S; Nag S; Nasrazadani S; Ukirde V; El Bouanani M; Mohandas A; Nguyen K; Banerjee R
    J Biomed Mater Res A; 2010 Sep; 94(4):1251-6. PubMed ID: 20694992
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of titanium-tantalum and titanium-niobium alloys for application as dental implants.
    Breme J; Wadewitz V
    Int J Oral Maxillofac Implants; 1989; 4(2):113-8. PubMed ID: 2599582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
    Wang QY; Zheng YF
    Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrochemical characterization of cast Ti-Hf binary alloys.
    Cai Z; Koike M; Sato H; Brezner M; Guo Q; Komatsu M; Okuno O; Okabe T
    Acta Biomater; 2005 May; 1(3):353-6. PubMed ID: 16701813
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New titanium alloys for biomaterials: a study of mechanical and corrosion properties and cytotoxicity.
    Kim TI; Han JH; Lee IS; Lee KH; Shin MC; Choi BB
    Biomed Mater Eng; 1997; 7(4):253-63. PubMed ID: 9408577
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electrochemical behavior of near-beta titanium biomedical alloys in phosphate buffer saline solution.
    Dalmau A; Guiñón Pina V; Devesa F; Amigó V; Igual Muñoz A
    Mater Sci Eng C Mater Biol Appl; 2015 Mar; 48():55-62. PubMed ID: 25579896
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel-titanium-based orthodontic wires at various temperatures.
    Pun DK; Berzins DW
    Dent Mater; 2008 Feb; 24(2):221-7. PubMed ID: 17624421
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigations on the galvanic corrosion of multialloy total hip prostheses.
    Lucas LC; Buchanan RA; Lemons JE
    J Biomed Mater Res; 1981 Sep; 15(5):731-47. PubMed ID: 12659138
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The role of lipopolysaccharide on the electrochemical behavior of titanium.
    Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
    J Dent Res; 2011 May; 90(5):613-8. PubMed ID: 21335537
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.