These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 9475577)

  • 1. Why a large tip electrode makes a deeper radiofrequency lesion: effects of increase in electrode cooling and electrode-tissue interface area.
    Otomo K; Yamanashi WS; Tondo C; Antz M; Bussey J; Pitha JV; Arruda M; Nakagawa H; Wittkampf FH; Lazzara R; Jackman WM
    J Cardiovasc Electrophysiol; 1998 Jan; 9(1):47-54. PubMed ID: 9475577
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation.
    Nakagawa H; Yamanashi WS; Pitha JV; Arruda M; Wang X; Ohtomo K; Beckman KJ; McClelland JH; Lazzara R; Jackman WM
    Circulation; 1995 Apr; 91(8):2264-73. PubMed ID: 7697856
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling.
    Nakagawa H; Wittkampf FH; Yamanashi WS; Pitha JV; Imai S; Campbell B; Arruda M; Lazzara R; Jackman WM
    Circulation; 1998 Aug; 98(5):458-65. PubMed ID: 9714097
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiofrequency catheter ablation with the split-tip electrode in the temperature-controlled mode.
    Antz M; Otomo K; Nakagawa H; Yamanashi WS; Jackman WM; Kuck KH
    Pacing Clin Electrophysiol; 2001 Dec; 24(12):1765-73. PubMed ID: 11817810
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop.
    Yokoyama K; Nakagawa H; Wittkampf FH; Pitha JV; Lazzara R; Jackman WM
    Circulation; 2006 Jan; 113(1):11-9. PubMed ID: 16380552
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temperature measurement as a determinant of tissue heating during radiofrequency catheter ablation: an examination of electrode thermistor positioning for measurement accuracy.
    McRury ID; Whayne JG; Haines DE
    J Cardiovasc Electrophysiol; 1995 Apr; 6(4):268-78. PubMed ID: 7647952
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Gold-tip electrodes--a new "deep lesion" technology for catheter ablation? In vitro comparison of a gold alloy versus platinum-iridium tip electrode ablation catheter.
    Lewalter T; Bitzen A; Wurtz S; Blum R; Schlodder K; Yang A; Lickfett L; Schwab JO; Schrickel JW; Tiemann K; Linhart M; Zima E; Merkely B; Lüderitz B
    J Cardiovasc Electrophysiol; 2005 Jul; 16(7):770-2. PubMed ID: 16050836
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Interrelation of tissue temperature versus flow velocity in two different kinds of temperature controlled catheter radiofrequency energy applications.
    Grumbrecht S; Neuzner J; Pitschner HF
    J Interv Card Electrophysiol; 1998 Jun; 2(2):211-9. PubMed ID: 9870015
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High incidence of thrombus formation without impedance rise during radiofrequency ablation using electrode temperature control.
    Matsudaira K; Nakagawa H; Wittkampf FH; Yamanashi WS; Imai S; Pitha JV; Lazzara R; Jackman WM
    Pacing Clin Electrophysiol; 2003 May; 26(5):1227-37. PubMed ID: 12765451
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can lesion size during radiofrequency ablation be predicted by the temperature rise to a low power test pulse in vitro?
    Petersen HH; Svendsen JH
    Pacing Clin Electrophysiol; 2003 Aug; 26(8):1653-9. PubMed ID: 12877696
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Safety profiles and lesion size of different radiofrequency ablation technologies: a comparison of large tip, open and closed irrigation catheters.
    Everett TH; Lee KW; Wilson EE; Guerra JM; Varosy PD; Olgin JE
    J Cardiovasc Electrophysiol; 2009 Mar; 20(3):325-35. PubMed ID: 18803562
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium.
    Chan RC; Johnson SB; Seward JB; Packer DL
    Pacing Clin Electrophysiol; 2002 Jan; 25(1):4-13. PubMed ID: 11877935
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Temperature-controlled radiofrequency ablation of cardiac tissue: an in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling.
    Petersen HH; Chen X; Pietersen A; Svendsen JH; Haunso S
    J Interv Card Electrophysiol; 1999 Oct; 3(3):257-62. PubMed ID: 10490483
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Biophysics of Passive Convective Cooling During Catheter Ablation with Gold versus Platinum Electrodes and Multielectrode Phased Radiofrequency Energy Delivery.
    Haines DE; Strunk AR; Novichenok A; Kirchhof N; Stewart M
    J Cardiovasc Electrophysiol; 2015 Nov; 26(11):1257-1261. PubMed ID: 26179194
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microwave ablation using a spiral antenna design in a porcine thigh muscle preparation: in vivo assessment of temperature profile and lesion geometry.
    Vanderbrink BA; Gu Z; Rodriguez V; Link MS; Homoud MK; Estes NA; Rappaport CM; Wang PJ
    J Cardiovasc Electrophysiol; 2000 Feb; 11(2):193-8. PubMed ID: 10709714
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the temperature profile and pathological effect at unipolar, bipolar and phased radiofrequency current configurations.
    Zheng X; Walcott GP; Rollins DL; Hall JA; Smith WM; Kay GN; Ideker RE
    J Interv Card Electrophysiol; 2001 Dec; 5(4):401-10. PubMed ID: 11752908
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus.
    Yokoyama K; Nakagawa H; Shah DC; Lambert H; Leo G; Aeby N; Ikeda A; Pitha JV; Sharma T; Lazzara R; Jackman WM
    Circ Arrhythm Electrophysiol; 2008 Dec; 1(5):354-62. PubMed ID: 19808430
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling.
    Høgh Petersen H; Chen X; Pietersen A; Svendsen JH; Haunsø S
    Circulation; 1999 Jan; 99(2):319-25. PubMed ID: 9892601
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiofrequency ablation at low irrigation flow rates using a novel 12-hole gold open-irrigation catheter.
    Akca F; Zima E; Végh EM; Széplaki G; Skopál J; Hubay M; Lendvai Z; Merkely B; Szili-Torok T
    Pacing Clin Electrophysiol; 2013 Nov; 36(11):1373-81. PubMed ID: 23875670
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiofrequency catheter ablation using cooled electrodes: impact of irrigation flow rate and catheter contact pressure on lesion dimensions.
    Weiss C; Antz M; Eick O; Eshagzaiy K; Meinertz T; Willems S
    Pacing Clin Electrophysiol; 2002 Apr; 25(4 Pt 1):463-9. PubMed ID: 11991372
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.