These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
214 related articles for article (PubMed ID: 9476354)
1. A simple method for the eradication of Legionella pneumophila from potable water systems. Moreno C; de Blas I; Miralles F; Apraiz D; Catalan V Can J Microbiol; 1997 Dec; 43(12):1189-96. PubMed ID: 9476354 [TBL] [Abstract][Full Text] [Related]
2. Persistence of chlorine-sensitive Legionella pneumophila in hyperchlorinated installations. García MT; Baladrón B; Gil V; Tarancon ML; Vilasau A; Ibañez A; Elola C; Pelaz C J Appl Microbiol; 2008 Sep; 105(3):837-47. PubMed ID: 18557962 [TBL] [Abstract][Full Text] [Related]
3. Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species. Mouchtouri V; Velonakis E; Hadjichristodoulou C Am J Infect Control; 2007 Nov; 35(9):623-7. PubMed ID: 17980243 [TBL] [Abstract][Full Text] [Related]
4. Controlling Legionella pneumophila in water systems at reduced hot water temperatures with copper and silver ionization. Cloutman-Green E; Barbosa VL; Jimenez D; Wong D; Dunn H; Needham B; Ciric L; Hartley JC Am J Infect Control; 2019 Jul; 47(7):761-766. PubMed ID: 30661910 [TBL] [Abstract][Full Text] [Related]
5. Legionella Colonization of Hotel Water Systems in Touristic Places of Greece: Association with System Characteristics and Physicochemical Parameters. Kyritsi MA; Mouchtouri VA; Katsioulis A; Kostara E; Nakoulas V; Hatzinikou M; Hadjichristodoulou C Int J Environ Res Public Health; 2018 Nov; 15(12):. PubMed ID: 30513698 [TBL] [Abstract][Full Text] [Related]
6. Water fittings as sources of Legionella pneumophila in a hospital plumbing system. Colbourne JS; Pratt DJ; Smith MG; Fisher-Hoch SP; Harper D Lancet; 1984 Jan; 1(8370):210-3. PubMed ID: 6141347 [TBL] [Abstract][Full Text] [Related]
7. [Management of the Legionella-link risk in a multicentre area's hospital: lessons learned of a six-year experience]. Lecointe D; Fagundez E; Pierron P; Musset JP; Brissé P; Vollereau D; Breton D; Théodora C; Beauvais R; Malbrunot C; Crine L; Fèvre C; Pathol Biol (Paris); 2010 Apr; 58(2):131-6. PubMed ID: 19875245 [TBL] [Abstract][Full Text] [Related]
8. A 17-month evaluation of a chlorine dioxide water treatment system to control Legionella species in a hospital water supply. Srinivasan A; Bova G; Ross T; Mackie K; Paquette N; Merz W; Perl TM Infect Control Hosp Epidemiol; 2003 Aug; 24(8):575-9. PubMed ID: 12940577 [TBL] [Abstract][Full Text] [Related]
9. Potable water as a source of Legionnaires' disease. Shands KN; Ho JL; Meyer RD; Gorman GW; Edelstein PH; Mallison GF; Finegold SM; Fraser DW JAMA; 1985 Mar; 253(10):1412-6. PubMed ID: 3968771 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of Legionella pneumophila contamination in Italian hotel water systems by quantitative real-time PCR and culture methods. Bonetta S; Bonetta S; Ferretti E; Balocco F; Carraro E J Appl Microbiol; 2010 May; 108(5):1576-83. PubMed ID: 19796090 [TBL] [Abstract][Full Text] [Related]
11. Water heater temperature set point and water use patterns influence Legionella pneumophila and associated microorganisms at the tap. Rhoads WJ; Ji P; Pruden A; Edwards MA Microbiome; 2015 Dec; 3():67. PubMed ID: 26627188 [TBL] [Abstract][Full Text] [Related]
12. [Prevalence of Legionella in cooling towers in the Community of Madrid]. Ordóñez-Iriarte JM; Ferrer-Simó JB; Pelaz-Antolín C; García-Comas L; Med Clin (Barc); 2006 Feb; 126(5):189-95. PubMed ID: 16469281 [No Abstract] [Full Text] [Related]
13. [Prevention and control of Legionella infection in the hospital environment]. Borella P; Bargellini A; Pergolizzi S; Aggazzotti G; Curti C; Nizzero P; Stancanelli G; Vaiani R; Gesù G; Mazzuconi R Ann Ig; 2000; 12(4):287-96. PubMed ID: 11140095 [TBL] [Abstract][Full Text] [Related]
14. Quantitative assessment of biocide control of biofilms including Legionella pneumophila using total viable counts, fluorescence microscopy, and image analysis. Walker JT; Roberts AD; Lucas VJ; Roper MA; Brown RG Methods Enzymol; 1999; 310():629-37. PubMed ID: 10547824 [No Abstract] [Full Text] [Related]
15. Incorporation of natural uncultivable Legionella pneumophila into potable water biofilms provides a protective niche against chlorination stress. Gião MS; Wilks S; Azevedo NF; Vieira MJ; Keevil CW Biofouling; 2009; 25(4):345-51. PubMed ID: 23110528 [TBL] [Abstract][Full Text] [Related]
18. Treatment of a Legionella pneumophila-colonized water distribution system using copper-silver ionization and continuous chlorination. Biurrun A; Caballero L; Pelaz C; León E; Gago A Infect Control Hosp Epidemiol; 1999 Jun; 20(6):426-8. PubMed ID: 10395146 [TBL] [Abstract][Full Text] [Related]
19. [Practical experience with control of Legionella in cold water circulation systems by water conditioning measures]. Germann R; Henkels WD; Challinor CJ Schriftenr Ver Wasser Boden Lufthyg; 1993; 91():241-8. PubMed ID: 8235480 [No Abstract] [Full Text] [Related]
20. Efficacy of point-of-entry copper--silver ionisation system in eradicating Legionella pneumophila in a tropical tertiary care hospital: implications for hospitals contaminated with Legionella in both hot and cold water. Chen YS; Lin YE; Liu YC; Huang WK; Shih HY; Wann SR; Lee SS; Tsai HC; Li CH; Chao HL; Ke CM; Lu HH; Chang CL J Hosp Infect; 2008 Feb; 68(2):152-8. PubMed ID: 18192074 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]