These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 9483778)

  • 1. Design and preliminary results of an ultrasound applicator for interstitial thermal coagulation.
    Lafon C; Chapelon JY; Prat F; Gorry F; Margonari J; Theillère Y; Cathignol D
    Ultrasound Med Biol; 1998 Jan; 24(1):113-22. PubMed ID: 9483778
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrasound applicators with internal water-cooling for high-powered interstitial thermal therapy.
    Deardorff DL; Diederich CJ
    IEEE Trans Biomed Eng; 2000 Oct; 47(10):1356-65. PubMed ID: 11059170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design and in vitro results of a high intensity ultrasound interstitial applicator.
    Lafon C; Chapelon JY; Prat F; Gorry F; Theillère Y; Cathignol D
    Ultrasonics; 1998 Feb; 36(1-5):683-7. PubMed ID: 9651597
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of multielement catheter-cooled interstitial ultrasound applicators for high-temperature thermal therapy.
    Nau WH; Diederich CJ; Burdette EC
    Med Phys; 2001 Jul; 28(7):1525-34. PubMed ID: 11488586
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Angular directivity of thermal coagulation using air-cooled direct-coupled interstitial ultrasound applicators.
    Deardorff DL; Diederich CJ
    Ultrasound Med Biol; 1999 May; 25(4):609-22. PubMed ID: 10386737
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multisectored interstitial ultrasound applicators for dynamic angular control of thermal therapy.
    Kinsey AM; Diederich CJ; Tyreus PD; Nau WH; Rieke V; Pauly KB
    Med Phys; 2006 May; 33(5):1352-63. PubMed ID: 16752571
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model.
    Adams MS; Salgaonkar VA; Plata-Camargo J; Jones PD; Pascal-Tenorio A; Chen HY; Bouley DM; Sommer G; Pauly KB; Diederich CJ
    Med Phys; 2016 Jul; 43(7):4184. PubMed ID: 27370138
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimizing the shape of ultrasound transducers for interstitial thermal ablation.
    Lafon C; de L; Theillère Y; Prat F; Chapelon JY; Cathignol D
    Med Phys; 2002 Mar; 29(3):290-7. PubMed ID: 11929011
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Water-cooled, high-intensity ultrasound surgical applicators with frequency tracking.
    Martin RW; Vaezy S; Proctor A; Myntti T; Lee JB; Crum LA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2003 Oct; 50(10):1305-17. PubMed ID: 14609070
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Curvilinear transurethral ultrasound applicator for selective prostate thermal therapy.
    Ross AB; Diederich CJ; Nau WH; Rieke V; Butts RK; Sommer G; Gill H; Bouley DM
    Med Phys; 2005 Jun; 32(6):1555-65. PubMed ID: 16013714
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Control of interstitial thermal coagulation: comparative evaluation of microwave and ultrasound applicators.
    Deardorff DL; Diederich CJ; Nau WH
    Med Phys; 2001 Jan; 28(1):104-17. PubMed ID: 11213915
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual-mode transducers for ultrasound imaging and thermal therapy.
    Owen NR; Chapelon JY; Bouchoux G; Berriet R; Fleury G; Lafon C
    Ultrasonics; 2010 Feb; 50(2):216-20. PubMed ID: 19758673
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Integration of deployable fluid lenses and reflectors with endoluminal therapeutic ultrasound applicators: Preliminary investigations of enhanced penetration depth and focal gain.
    Adams MS; Salgaonkar VA; Scott SJ; Sommer G; Diederich CJ
    Med Phys; 2017 Oct; 44(10):5339-5356. PubMed ID: 28681404
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Air-cooling of direct-coupled ultrasound applicators for interstitial hyperthermia and thermal coagulation.
    Deardorff DL; Diederich CJ; Nau WH
    Med Phys; 1998 Dec; 25(12):2400-9. PubMed ID: 9874834
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Theoretical model of internally cooled interstitial ultrasound applicators for thermal therapy.
    Tyréus PD; Diederich CJ
    Phys Med Biol; 2002 Apr; 47(7):1073-89. PubMed ID: 11996056
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multiple applicator hepatic ablation with interstitial ultrasound devices: theoretical and experimental investigation.
    Prakash P; Salgaonkar VA; Clif Burdette E; Diederich CJ
    Med Phys; 2012 Dec; 39(12):7338-49. PubMed ID: 23231283
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Deployable ultrasound applicators for endoluminal delivery of volumetric hyperthermia.
    Zubair M; Adams MS; Diederich CJ
    Int J Hyperthermia; 2021 Aug; 38(1):1188-1204. PubMed ID: 34376103
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Combination of thermal and cavitation effects to generate deep lesions with an endocavitary applicator using a plane transducer: ex vivo studies.
    Melodelima D; Chapelon JY; Theillère Y; Cathignol D
    Ultrasound Med Biol; 2004 Jan; 30(1):103-11. PubMed ID: 14962614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Axial control of thermal coagulation using a multi-element interstitial ultrasound applicator with internal cooling.
    Deardorff DL; Diederich CJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(1):170-8. PubMed ID: 18238528
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of two methods of treatment for intraluminal thermal ablation using an ultrasound cylindrical phased array.
    Melodelima D; Prat F; Birer A; Theillère Y; Cathignol D
    Ultrasonics; 2004 Apr; 42(1-9):937-42. PubMed ID: 15047410
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.