These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 948608)
21. [Speed S sensitivity of film-screen systems and mode of action of different automatic illumination in general practice. I: Film-screen systems]. Blendl C; Kondmann M; Müller J Aktuelle Radiol; 1997 Sep; 7(5):288-94. PubMed ID: 9410006 [TBL] [Abstract][Full Text] [Related]
22. [Effect of intensifying screens on x-ray exposure contrast]. Brandt GA; Preuss HJ; Menzel B Radiol Diagn (Berl); 1980; 21(2):251-9. PubMed ID: 7444037 [No Abstract] [Full Text] [Related]
23. [The effect of increased performance of modern x-ray tubes on improvements in picture quality, particularly of moving organs (author's transl)]. Meiler J Rofo; 1976 Jul; 125(1):70-8. PubMed ID: 133950 [TBL] [Abstract][Full Text] [Related]
24. Techniques and applications of automatic tube current modulation for CT. Kalra MK; Maher MM; Toth TL; Schmidt B; Westerman BL; Morgan HT; Saini S Radiology; 2004 Dec; 233(3):649-57. PubMed ID: 15498896 [TBL] [Abstract][Full Text] [Related]
25. A scanning system for chest radiography with regional exposure control: theoretical considerations. Plewes DB Med Phys; 1983; 10(5):646-54. PubMed ID: 6646070 [TBL] [Abstract][Full Text] [Related]
26. Clarifying and visualizing sources of staff-received scattered radiation in interventional procedures. Chida K; Takahashi T; Ito D; Shimura H; Takeda K; Zuguchi M AJR Am J Roentgenol; 2011 Nov; 197(5):W900-3. PubMed ID: 22021539 [TBL] [Abstract][Full Text] [Related]
27. Physics overview of screen-film radiography. Ritenour ER Radiographics; 1996 Jul; 16(4):903-16. PubMed ID: 8835979 [TBL] [Abstract][Full Text] [Related]
28. Long-term stability of beam quality and output of conventional X-ray units. Fukuda A; Matsubara K; Miyati T Radiol Phys Technol; 2015 Jan; 8(1):26-9. PubMed ID: 25070378 [TBL] [Abstract][Full Text] [Related]
29. Laser alignment system for high-quality portable radiography. MacMahon H; Yasillo NJ; Carlin M Radiographics; 1992 Jan; 12(1):111-20. PubMed ID: 1734456 [TBL] [Abstract][Full Text] [Related]
30. New x-ray tube performance in computed tomography by introducing the rotating envelope tube technology. Schardt P; Deuringer J; Freudenberger J; Hell E; Knüpfer W; Mattern D; Schild M Med Phys; 2004 Sep; 31(9):2699-706. PubMed ID: 15487753 [TBL] [Abstract][Full Text] [Related]
31. [Nuclear physics, radiation protection, roentgen technology. Roentgen exposure systems (review report)]. Friedrich C Radiol Diagn (Berl); 1978 Apr; 19(2):269-81. PubMed ID: 674617 [No Abstract] [Full Text] [Related]
32. Shaping X-ray spectra with filters in X-ray diagnostics. Sandborg M; Carlsson CA; Carlsson GA Med Biol Eng Comput; 1994 Jul; 32(4):384-90. PubMed ID: 7967802 [TBL] [Abstract][Full Text] [Related]
33. Radiographic detail and variation of the nominal focal spot size: the "focal effect". Katz MC; Nickoloff EL Radiographics; 1992 Jul; 12(4):753-61. PubMed ID: 1636037 [TBL] [Abstract][Full Text] [Related]