These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
70 related articles for article (PubMed ID: 9492510)
41. Performance of selected flow-restricting infusion devices. Capes DF; Asiimwe D Am J Health Syst Pharm; 1998 Feb; 55(4):351-9. PubMed ID: 9504194 [TBL] [Abstract][Full Text] [Related]
42. The flow rate of the elastomeric balloon infusor is influenced by the internal pressure of the infusor. Chung IS; Cho HS; Kim JA; Lee KH J Korean Med Sci; 2001 Dec; 16(6):702-6. PubMed ID: 11748348 [TBL] [Abstract][Full Text] [Related]
43. [Evaluation of 3 peristaltic pumps for infusion of formulations for enteral nutrition]. Abad Gimeno FJ; Marco Sena MA; Casterá Melchor MD Nutr Hosp; 1990; 5(3):183-6. PubMed ID: 2127713 [TBL] [Abstract][Full Text] [Related]
44. Evaluation of flow rates for six disposable infusion devices. Veal DF; Altman CE; McKinnon BT; Fillingim O Am J Health Syst Pharm; 1995 Mar; 52(5):500-4. PubMed ID: 7677861 [TBL] [Abstract][Full Text] [Related]
45. [A sterile, regulated, pulsation-dampened precision dosing system for biomedical technics]. Merz H; Pandit M; Oldendorf C Biomed Tech (Berl); 1990; 35(1-2):5-9. PubMed ID: 2317543 [TBL] [Abstract][Full Text] [Related]
46. New portable infusion pumps: real advantages or just more of the same in a different package? Ilfeld BM; Morey TE; Enneking FK Reg Anesth Pain Med; 2004; 29(4):371-6. PubMed ID: 15305260 [No Abstract] [Full Text] [Related]
55. [Calculation of the capacity of a roller pump]. Vlasov VM; Gal'perin IuM; Karichev ZR; Muler AL Med Tekh; 1987; (3):32-6. PubMed ID: 3613944 [TBL] [Abstract][Full Text] [Related]
56. [A comparative study of the performance of 3 perfusion pumps: AVI 200, IMED 960 and Vial Medical 8000 M]. Cazalaà JB; Carbognani D; Cléro B; Barrier G Agressologie; 1988 Dec; 29(12 Spec No):818-23. PubMed ID: 3250273 [No Abstract] [Full Text] [Related]
57. Impact of air temperature and drug concentration on liquid emission from elastomeric pumps. Abe T; Matsuzaka K; Nakayama T; Otsuka M; Sagara A; Sato F; Yumoto T J Pharm Health Care Sci; 2021 Jan; 7(1):1. PubMed ID: 33397508 [TBL] [Abstract][Full Text] [Related]
58. In the market for an electronic infuser? Am J Nurs; 1988 Sep; 88(9):1225A-1226A. PubMed ID: 3414761 [No Abstract] [Full Text] [Related]
59. [Evaluation of the temperature dependent flow rate in three portable epidural infusion devices]. Kita A; Watanabe H; Namiki A Masui; 1998 Jan; 47(1):98-101. PubMed ID: 9492510 [TBL] [Abstract][Full Text] [Related]
60. [Evaluation of the safety of a new portable pump for continuous epidural infusion of local anesthetics]. Matsumoto S; Mitsuhata H; Shigeomi S; Matsumoto J; Yabe M; Terada M Masui; 1990 Sep; 39(9):1245-51. PubMed ID: 2246815 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]