These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
161 related articles for article (PubMed ID: 9493929)
1. Detection of respiratory events during NPSG: nasal cannula/pressure sensor versus thermistor. Norman RG; Ahmed MM; Walsleben JA; Rapoport DM Sleep; 1997 Dec; 20(12):1175-84. PubMed ID: 9493929 [TBL] [Abstract][Full Text] [Related]
2. Use of nasal cannula for detecting sleep apneas and hypopneas in infants and children. Trang H; Leske V; Gaultier C Am J Respir Crit Care Med; 2002 Aug; 166(4):464-8. PubMed ID: 12186821 [TBL] [Abstract][Full Text] [Related]
4. Detection of flow limitation with a nasal cannula/pressure transducer system. Hosselet JJ; Norman RG; Ayappa I; Rapoport DM Am J Respir Crit Care Med; 1998 May; 157(5 Pt 1):1461-7. PubMed ID: 9603124 [TBL] [Abstract][Full Text] [Related]
5. [Evaluating oronasal flow with temperature (thermistor) and obstructive pressure (prongs)]. Rühle KH; Fahrner A; Randerath W Pneumologie; 2001 Jan; 55(1):4-6. PubMed ID: 11236356 [TBL] [Abstract][Full Text] [Related]
6. Assessment of inspiratory flow limitation in children with sleep-disordered breathing by a nasal cannula pressure transducer system. Serebrisky D; Cordero R; Mandeli J; Kattan M; Lamm C Pediatr Pulmonol; 2002 May; 33(5):380-7. PubMed ID: 11948984 [TBL] [Abstract][Full Text] [Related]
7. Comparison of nasal pressure transducer and thermistor for detection of respiratory events during polysomnography in children. Budhiraja R; Goodwin JL; Parthasarathy S; Quan SF Sleep; 2005 Sep; 28(9):1117-21. PubMed ID: 16268381 [TBL] [Abstract][Full Text] [Related]
8. Improved detection of obstructive events in childhood sleep apnoea with the use of the nasal cannula and the differentiated sum signal. Griffiths A; Maul J; Wilson A; Stick S J Sleep Res; 2005 Dec; 14(4):431-6. PubMed ID: 16364144 [TBL] [Abstract][Full Text] [Related]
9. Comparison of limited monitoring using a nasal-cannula flow signal to full polysomnography in sleep-disordered breathing. Ayappa I; Norman RG; Suryadevara M; Rapoport DM Sleep; 2004 Sep; 27(6):1171-9. PubMed ID: 15532212 [TBL] [Abstract][Full Text] [Related]
10. Immediate consequences of respiratory events in sleep disordered breathing. Ayappa I; Rapaport BS; Norman RG; Rapoport DM Sleep Med; 2005 Mar; 6(2):123-30. PubMed ID: 15716216 [TBL] [Abstract][Full Text] [Related]
11. [Tools available for the diagnosis of obstructive sleep apnea syndrome. Measurements for the evaluation of therapeutic efficacy]. Pépin JL; Bettega G; Orliaguet O; Raphaël B; Lévy P Rev Stomatol Chir Maxillofac; 2002 Jun; 103(3):151-7. PubMed ID: 12486888 [TBL] [Abstract][Full Text] [Related]
12. The scoring of respiratory events in sleep: reliability and validity. Redline S; Budhiraja R; Kapur V; Marcus CL; Mateika JH; Mehra R; Parthasarthy S; Somers VK; Strohl KP; Sulit LG; Gozal D; Wise MS; Quan SF J Clin Sleep Med; 2007 Mar; 3(2):169-200. PubMed ID: 17557426 [TBL] [Abstract][Full Text] [Related]
13. Scoring respiratory events in paediatric patients: evaluation of nasal pressure and thermistor recordings separately and in combination. Verginis N; Davey MJ; Horne RS Sleep Med; 2010 Apr; 11(4):400-5. PubMed ID: 20189872 [TBL] [Abstract][Full Text] [Related]
14. Comparison of nasal prong pressure and thermistor measurements for detecting respiratory events during sleep. BaHammam A Respiration; 2004; 71(4):385-90. PubMed ID: 15316213 [TBL] [Abstract][Full Text] [Related]
15. Nasal cannula use during polysomnography in children aged under three with suspected sleep apnea. Jurado MJ; Sampol G; Quintana M; Romero O; Cambrodí R; Ferré A; Sampol J Sleep Med; 2022 Nov; 99():41-48. PubMed ID: 35947888 [TBL] [Abstract][Full Text] [Related]
16. Detection of upper airway resistance syndrome using a nasal cannula/pressure transducer. Epstein MD; Chicoine SA; Hanumara RC Chest; 2000 Apr; 117(4):1073-7. PubMed ID: 10767242 [TBL] [Abstract][Full Text] [Related]
17. Scoring polysomnography respiratory events: the utility of nasal pressure and oro-nasal thermal sensor recordings. Teichtahl H; Cunnington D; Cherry G; Wang D Sleep Med; 2003 Sep; 4(5):419-25. PubMed ID: 14592283 [TBL] [Abstract][Full Text] [Related]
18. [Ambulatory monitoring of patients with suspected sleep apnea syndrome using a thermistor sensor in comparison with nocturnal polysomnography]. Mössinger B; Kellner C; Rühle KH Pneumologie; 1993 Mar; 47 Suppl 1():122-5. PubMed ID: 8497462 [TBL] [Abstract][Full Text] [Related]
19. Non-Invasive detection of respiratory effort-related arousals (REras) by a nasal cannula/pressure transducer system. Ayappa I; Norman RG; Krieger AC; Rosen A; O'malley RL; Rapoport DM Sleep; 2000 Sep; 23(6):763-71. PubMed ID: 11007443 [TBL] [Abstract][Full Text] [Related]
20. [Detecting sleep apnea/hypopnea events with a wearable respiratory inductive plethysmograph system]. Zhang Z; Bi Y; Yu M; Wu T; Li R Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):318-22. PubMed ID: 18610614 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]