These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 9498668)

  • 21. A method for the determination of amitriptyline and its metabolites nortriptyline, 10-hydroxyamitriptyline, and 10-hydroxynortriptyline in human plasma using stable isotope dilution and gas chromatography-chemical ionization mass spectrometry (GC-CIMS).
    Garland WA; Muccino RR; Min BH; Cupano J; Fann WE
    Clin Pharmacol Ther; 1979 Jun; 25(6):844-56. PubMed ID: 376209
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Stable isotope labeling-assisted GC/MS/MS method for determination of methyleugenol in food samples.
    Li J; Liu H; Wang C; Yang J; Han G
    J Sci Food Agric; 2018 Jul; 98(9):3485-3491. PubMed ID: 29314056
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Determination of total cholesterol in serum by liquid chromatography-isotope dilution mass spectrometry.
    Kock R; Delvoux B; Greiling H
    Clin Chem; 1997 Oct; 43(10):1896-903. PubMed ID: 9342010
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Quantitative analysis of 39 polybrominated diphenyl ethers by isotope dilution GC/low-resolution MS.
    Ackerman LK; Wilson GR; Simonich SL
    Anal Chem; 2005 Apr; 77(7):1979-87. PubMed ID: 15801727
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Determination of creatinine in human serum by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, IV.
    Siekmann L
    J Clin Chem Clin Biochem; 1985 Mar; 23(3):137-44. PubMed ID: 3889218
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Determination of polybrominated diphenyl ethers and novel brominated flame retardants in human serum by gas chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.
    Wang Y; Sun Y; Chen T; Shi Z; Zhou X; Sun Z; Zhang L; Li J
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Nov; 1099():64-72. PubMed ID: 30243115
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Stable isotope dilution negative ion chemical ionization gas chromatography-mass spectrometry for the quantitative analysis of paroxetine in human plasma.
    Leis HJ; Windischhofer W; Raspotnig G; Fauler G
    J Mass Spectrom; 2001 Aug; 36(8):923-8. PubMed ID: 11523092
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Analysis of 2-aminoacetophenone in wine using a stable isotope dilution assay and multidimensional gas chromatography-mass spectrometry.
    Schmarr HG; Ganss S; Sang W; Potouridis T
    J Chromatogr A; 2007 May; 1150(1-2):78-84. PubMed ID: 17014858
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Determination of endogenous agmatine in rat plasma by isotope dilution-gas chromatography-mass spectrometry].
    Qiu Z; Lin Y; Xiong Z; Xie J
    Se Pu; 2014 Jul; 32(7):779-83. PubMed ID: 25255573
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Neurochemical analysis of amino acids, polyamines and carboxylic acids: GC-MS quantitation of tBDMS derivatives using ammonia positive chemical ionization.
    Wood PL; Khan MA; Moskal JR
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Feb; 831(1-2):313-9. PubMed ID: 16406747
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Determination of buprenorphine in human plasma by gas chromatography-positive ion chemical ionization mass spectrometry and liquid chromatography-tandem mass spectrometry.
    Moody DE; Laycock JD; Spanbauer AC; Crouch DJ; Foltz RL; Josephs JL; Amass L; Bickel WK
    J Anal Toxicol; 1997 Oct; 21(6):406-14. PubMed ID: 9323518
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Validation of an isotope dilution gas chromatography-mass spectrometry method for combined analysis of oxysterols and oxyphytosterols in serum samples.
    Schött HF; Lütjohann D
    Steroids; 2015 Jul; 99(Pt B):139-50. PubMed ID: 25701095
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Benzodiazepine analysis by negative chemical ionization gas chromatography/mass spectrometry.
    Fitzgerald RL; Rexin DA; Herold DA
    J Anal Toxicol; 1993 Oct; 17(6):342-7. PubMed ID: 8271780
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Determination of blood lead by electron-capture negative chemical ionization gas chromatography-mass spectrometry.
    Baird GS; Fitzgerald RL; Aggarwal SK; Herold DA
    Clin Chem; 1996 Feb; 42(2):286-91. PubMed ID: 8595725
    [TBL] [Abstract][Full Text] [Related]  

  • 35. High mass accuracy assay for trimethylamine N-oxide using stable-isotope dilution with liquid chromatography coupled to orthogonal acceleration time of flight mass spectrometry with multiple reaction monitoring.
    Heaney LM; Jones DJ; Mbasu RJ; Ng LL; Suzuki T
    Anal Bioanal Chem; 2016 Jan; 408(3):797-804. PubMed ID: 26573169
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Quantitative determination of fluvastatin in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry using [18O2]-fluvastatin as an internal standard.
    Leis HJ; Windischhofer W
    Rapid Commun Mass Spectrom; 2005; 19(2):128-32. PubMed ID: 15593066
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Simultaneous assessment of the intravenous and oral disposition of the enantiomers of racemic nimodipine by chiral stationary-phase high-performance liquid chromatography and gas chromatography/mass spectroscopy combined with a stable isotope technique.
    Fischer C; Schönberger F; Mück W; Heuck K; Eichelbaum M
    J Pharm Sci; 1993 Mar; 82(3):244-50. PubMed ID: 8450415
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination of uric acid in human serum by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, III.
    Siekmann L
    J Clin Chem Clin Biochem; 1985 Mar; 23(3):129-35. PubMed ID: 3889217
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Negative ion chemical ionization for the determination of methylphenidate in human plasma by stable isotope dilution gas chromatography/mass spectrometry.
    Leis HJ; Fauler G; Raspotnig G; Windischhofer W
    J Mass Spectrom; 2000 Sep; 35(9):1100-4. PubMed ID: 11006603
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Determination of 5-methyltetrahydrofolic acid in human serum by stable-isotope dilution high-performance liquid chromatography-mass spectrometry.
    Pawlosky RJ; Flanagan VP; Pfeiffer CM
    Anal Biochem; 2001 Nov; 298(2):299-305. PubMed ID: 11700986
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.