39 related articles for article (PubMed ID: 9500264)
1. Telemedicine Interventional Therapy, Extra-cavity LV Image Registration….
Erol Ç
Anatol J Cardiol; 2024 Apr; 28(4):176. PubMed ID: 38551222
[No Abstract] [Full Text] [Related]
2. Fully automated convolutional neural network-based affine algorithm improves liver registration and lesion co-localization on hepatobiliary phase T1-weighted MR images.
Hasenstab KA; Cunha GM; Higaki A; Ichikawa S; Wang K; Delgado T; Brunsing RL; Schlein A; Bittencourt LK; Schwartzman A; Fowler KJ; Hsiao A; Sirlin CB
Eur Radiol Exp; 2019 Oct; 3(1):43. PubMed ID: 31655943
[TBL] [Abstract][Full Text] [Related]
3. Multimodal image registration for liver radioembolization planning and patient assessment.
Spahr N; Thoduka S; Abolmaali N; Kikinis R; Schenk A
Int J Comput Assist Radiol Surg; 2019 Feb; 14(2):215-225. PubMed ID: 30349976
[TBL] [Abstract][Full Text] [Related]
4. A prospective development study of software-guided radio-frequency ablation of primary and secondary liver tumors: Clinical intervention modelling, planning and proof for ablation cancer treatment (ClinicIMPPACT).
Reinhardt M; Brandmaier P; Seider D; Kolesnik M; Jenniskens S; Sequeiros RB; Eibisberger M; Voglreiter P; Flanagan R; Mariappan P; Busse H; Moche M;
Contemp Clin Trials Commun; 2017 Dec; 8():25-32. PubMed ID: 29696193
[TBL] [Abstract][Full Text] [Related]
5. Joint deformable liver registration and bias field correction for MR-guided HDR brachytherapy.
Rak M; König T; Tönnies KD; Walke M; Ricke J; Wybranski C
Int J Comput Assist Radiol Surg; 2017 Dec; 12(12):2169-2180. PubMed ID: 28685419
[TBL] [Abstract][Full Text] [Related]
6. Three-dimensional quantitative assessment of ablation margins based on registration of pre- and post-procedural MRI and distance map.
Tani S; Tatli S; Hata N; Garcia-Rojas X; Olubiyi OI; Silverman SG; Tokuda J
Int J Comput Assist Radiol Surg; 2016 Jun; 11(6):1133-42. PubMed ID: 27038962
[TBL] [Abstract][Full Text] [Related]
7. Motion correction of multi-b-value diffusion-weighted imaging in the liver.
Mazaheri Y; Do RK; Shukla-Dave A; Deasy JO; Lu Y; Akin O
Acad Radiol; 2012 Dec; 19(12):1573-80. PubMed ID: 22963726
[TBL] [Abstract][Full Text] [Related]
8. Multimodality non-rigid image registration for planning, targeting and monitoring during CT-guided percutaneous liver tumor cryoablation.
Elhawary H; Oguro S; Tuncali K; Morrison PR; Tatli S; Shyn PB; Silverman SG; Hata N
Acad Radiol; 2010 Nov; 17(11):1334-44. PubMed ID: 20817574
[TBL] [Abstract][Full Text] [Related]
9. Assessment of intraoperative liver deformation during hepatic resection: prospective clinical study.
Heizmann O; Zidowitz S; Bourquain H; Potthast S; Peitgen HO; Oertli D; Kettelhack C
World J Surg; 2010 Aug; 34(8):1887-93. PubMed ID: 20372896
[TBL] [Abstract][Full Text] [Related]
10. Concepts and preliminary data toward the realization of image-guided liver surgery.
Cash DM; Miga MI; Glasgow SC; Dawant BM; Clements LW; Cao Z; Galloway RL; Chapman WC
J Gastrointest Surg; 2007 Jul; 11(7):844-59. PubMed ID: 17458587
[TBL] [Abstract][Full Text] [Related]
11. Real-time cardiac catheter navigation on three-dimensional CT images.
Solomon SB; Dickfeld T; Calkins H
J Interv Card Electrophysiol; 2003 Feb; 8(1):27-36. PubMed ID: 12652174
[TBL] [Abstract][Full Text] [Related]
12. Ablative therapy for liver tumours.
Dick EA; Taylor-Robinson SD; Thomas HC; Gedroyc WM
Gut; 2002 May; 50(5):733-9. PubMed ID: 11950826
[TBL] [Abstract][Full Text] [Related]
13. Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatment.
Carrillo A; Duerk JL; Lewin JS; Wilson DL
IEEE Trans Med Imaging; 2000 Mar; 19(3):175-85. PubMed ID: 10875702
[TBL] [Abstract][Full Text] [Related]
14. Comparison Between CT and MR Images as More Favorable Reference Data Sets for Fusion Imaging-Guided Radiofrequency Ablation or Biopsy of Hepatic Lesions: A Prospective Study with Focus on Patient's Respiration.
Cha DI; Lee MW; Kang TW; Oh YT; Jeong JY; Chang JW; Ryu J; Lee KJ; Kim J; Bang WC; Shin DK; Choi SJ; Koh D; Kim K
Cardiovasc Intervent Radiol; 2017 Oct; 40(10):1567-1575. PubMed ID: 28462444
[TBL] [Abstract][Full Text] [Related]
15. Non-Rigid Registration of Liver CT Images for CT-Guided Ablation of Liver Tumors.
Luu HM; Klink C; Niessen W; Moelker A; Walsum Tv
PLoS One; 2016; 11(9):e0161600. PubMed ID: 27611780
[TBL] [Abstract][Full Text] [Related]
16. Magnetic resonance guidance for radiofrequency ablation of liver tumors.
Clasen S; Pereira PL
J Magn Reson Imaging; 2008 Feb; 27(2):421-33. PubMed ID: 18219677
[TBL] [Abstract][Full Text] [Related]
17. Magnetic resonance imaging for hepatic radiofrequency ablation.
Clasen S; Boss A; Schmidt D; Fritz J; Schraml C; Claussen CD; Pereira PL
Eur J Radiol; 2006 Aug; 59(2):140-8. PubMed ID: 16716553
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of 3D image registration as applied to MR-guided thermal treatment of liver cancer.
Wilson DL; Carrillo A; Zheng L; Genc A; Duerk JL; Lewin JS
J Magn Reson Imaging; 1998; 8(1):77-84. PubMed ID: 9500264
[TBL] [Abstract][Full Text] [Related]
19.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
[Next] [New Search]