These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
111 related articles for article (PubMed ID: 9500895)
21. 3D localized 2D ultrafast J-resolved magnetic resonance spectroscopy: in vitro study on a 7 T imaging system. Roussel T; Giraudeau P; Ratiney H; Akoka S; Cavassila S J Magn Reson; 2012 Feb; 215():50-5. PubMed ID: 22227288 [TBL] [Abstract][Full Text] [Related]
22. SEMAC-VAT and MSVAT-SPACE sequence strategies for metal artifact reduction in 1.5T magnetic resonance imaging. Ai T; Padua A; Goerner F; Nittka M; Gugala Z; Jadhav S; Trelles M; Johnson RF; Lindsey RW; Li X; Runge VM Invest Radiol; 2012 May; 47(5):267-76. PubMed ID: 22266987 [TBL] [Abstract][Full Text] [Related]
23. A continuous phase-modulated approach to spatial encoding in ultrafast 2D NMR spectroscopy. Tal A; Shapira B; Frydman L J Magn Reson; 2005 Sep; 176(1):107-14. PubMed ID: 15949960 [TBL] [Abstract][Full Text] [Related]
24. Improved resolution in two-dimensional 1H NMR spectra of peptides by band-selective, homonuclear decoupling during both the evolution and acquisition periods: application to characterization of the binding of peptides by heparin. Wang J; Borchardt D; Rabenstein DL Magn Reson Chem; 2006 Aug; 44(8):744-52. PubMed ID: 16705624 [TBL] [Abstract][Full Text] [Related]
25. Adiabatic mixing in the liquid state. Kupce E; Schmidt P; Rance M; Wagner G J Magn Reson; 1998 Dec; 135(2):361-7. PubMed ID: 9878464 [TBL] [Abstract][Full Text] [Related]
26. Combination of homonuclear decoupling and spectral aliasing to increase the resolution in the (1)H dimension of 2D NMR experiments. Cotte A; Foroozandeh M; Jeannerat D Chimia (Aarau); 2012; 66(10):764-9. PubMed ID: 23146262 [TBL] [Abstract][Full Text] [Related]
28. PFG-omega1-filtered TOCSY experiments for the determination of long-range heteronuclear and homonuclear coupling constants and estimation of J-coupling "crosstalk" artifacts in 2-D omega1-filtered "E. COSY-style" spectra. Xu G; Zhang B; Evans JS J Magn Reson; 1999 May; 138(1):127-34. PubMed ID: 10329235 [TBL] [Abstract][Full Text] [Related]
29. RES-TOCSY: a simple approach to resolve overlapped ¹H NMR spectra of enantiomers. Lokesh ; Chaudhari SR; Suryaprakash N Org Biomol Chem; 2014 Feb; 12(6):993-7. PubMed ID: 24435319 [TBL] [Abstract][Full Text] [Related]
30. Assignment of protein NMR spectra in the light of homonuclear 3D spectroscopy: an automatable procedure based on 3D TOCSY-TOCSY and 3D TOCSY-NOESY. Oschkinat H; Holak TA; Cieslar C Biopolymers; 1991 May; 31(6):699-712. PubMed ID: 1932568 [TBL] [Abstract][Full Text] [Related]
31. [Diagnosis of renal artery stenosis with magnetic resonance angiography and stenosis quantification]. Marchand B; Hernandez-Hoyos M; Orkisz M; Douek P J Mal Vasc; 2000 Dec; 25(5):312-320. PubMed ID: 11148391 [TBL] [Abstract][Full Text] [Related]
32. Gradient-enhanced TOCSY experiments with improved sensitivity and solvent suppression. Fulton DB; Hrabal R; Ni F J Biomol NMR; 1996 Sep; 8(2):213-8. PubMed ID: 22911142 [TBL] [Abstract][Full Text] [Related]
33. Improved 3D gd-HCACO and gd-(H)CACO-TOCSY experiments for isotopically enriched proteins dissolved in H2O. Zhang W; Gmeiner WH J Biomol NMR; 1996 May; 7(3):247-50. PubMed ID: 8785500 [TBL] [Abstract][Full Text] [Related]
34. Free-breathing quantitative dynamic contrast-enhanced magnetic resonance imaging in a rat liver tumor model using dynamic radial T(1) mapping. Braren R; Curcic J; Remmele S; Altomonte J; Ebert O; Rummeny EJ; Steingoetter A Invest Radiol; 2011 Oct; 46(10):624-31. PubMed ID: 21577121 [TBL] [Abstract][Full Text] [Related]
35. J-ONLY-TOCSY: efficient suppression of RDC-induced transfer in homonuclear TOCSY experiments using JESTER-1-derived multiple pulse sequences. Klages J; Kessler H; Glaser SJ; Luy B J Magn Reson; 2007 Dec; 189(2):217-27. PubMed ID: 17936049 [TBL] [Abstract][Full Text] [Related]
36. Rapid single-breath-hold 3D late gadolinium enhancement cardiac MRI using a stack-of-spirals acquisition. Shin T; Lustig M; Nishimura DG; Hu BS J Magn Reson Imaging; 2014 Dec; 40(6):1496-502. PubMed ID: 24243575 [TBL] [Abstract][Full Text] [Related]
37. Compressed Sensing for Breast MRI: Resolving the Trade-Off Between Spatial and Temporal Resolution. Vreemann S; Rodriguez-Ruiz A; Nickel D; Heacock L; Appelman L; van Zelst J; Karssemeijer N; Weiland E; Maas M; Moy L; Kiefer B; Mann RM Invest Radiol; 2017 Oct; 52(10):574-582. PubMed ID: 28463932 [TBL] [Abstract][Full Text] [Related]
38. Practical aspects of the simultaneous collection of COSY and TOCSY spectra. Nolis P; Parella T Magn Reson Chem; 2019 Apr; 57(4):S85-S94. PubMed ID: 30676668 [TBL] [Abstract][Full Text] [Related]
39. In phase selective excitation of overlapping multiplets by gradient-enhanced chemical shift selective filters. Robinson PT; Pham TN; Uhrín D J Magn Reson; 2004 Sep; 170(1):97-103. PubMed ID: 15324762 [TBL] [Abstract][Full Text] [Related]
40. Tailored spiral in-out spectral-spatial water suppression pulses for magnetic resonance spectroscopic imaging. Ma J; Wismans C; Cao Z; Klomp DWJ; Wijnen JP; Grissom WA Magn Reson Med; 2018 Jan; 79(1):31-40. PubMed ID: 28370494 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]