These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
105 related articles for article (PubMed ID: 9503376)
21. Dosimetry in an IMRT phantom designed for a remote monitoring program. Han Y; Shin EH; Lim C; Kang SK; Park SH; Lah JE; Suh TS; Yoon M; Lee SB; Cho SH; Ibbott GS; Ju SG; Ahn YC Med Phys; 2008 Jun; 35(6):2519-27. PubMed ID: 18649485 [TBL] [Abstract][Full Text] [Related]
22. Utilization of thermoluminescent dosimetry in total skin electron beam radiotherapy of mycosis fungoides. Antolak JA; Cundiff JH; Ha CS Int J Radiat Oncol Biol Phys; 1998 Jan; 40(1):101-8. PubMed ID: 9422564 [TBL] [Abstract][Full Text] [Related]
23. Characterization of a new MOSFET detector configuration for in vivo skin dosimetry. Scalchi P; Francescon P; Rajaguru P Med Phys; 2005 Jun; 32(6):1571-8. PubMed ID: 16013716 [TBL] [Abstract][Full Text] [Related]
24. Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom. Schaeken B; Lelie S; Meijnders P; Van den Weyngaert D; Janssens H; Verellen D Med Phys; 2010 Dec; 37(12):6292-9. PubMed ID: 21302785 [TBL] [Abstract][Full Text] [Related]
25. Implementation of total body photon irradiation as part of an institutional bone marrow transplant program for the treatment of canine lymphoma and leukemias. Gieger TL; Nolan MW; Roback DM; Suter SE Vet Radiol Ultrasound; 2019 Sep; 60(5):586-593. PubMed ID: 31146304 [TBL] [Abstract][Full Text] [Related]
26. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry. McCaw TJ; Micka JA; DeWerd LA Med Phys; 2014 May; 41(5):052104. PubMed ID: 24784393 [TBL] [Abstract][Full Text] [Related]
27. Dose compensation of the total body irradiation therapy. Lin JP; Chu TC; Liu MT Appl Radiat Isot; 2001 Nov; 55(5):623-30. PubMed ID: 11573795 [TBL] [Abstract][Full Text] [Related]
28. The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: 'OPERA' (operational phantom for external radiotherapy audit). Swinnen A; Verstraete J; Huyskens D Radiother Oncol; 2002 Sep; 64(3):317-26. PubMed ID: 12242120 [TBL] [Abstract][Full Text] [Related]
29. [Basic and clinical studies of total body irradiation for bone marrow transplantation]. Kurisu K Nihon Igaku Hoshasen Gakkai Zasshi; 1991 Jul; 51(7):799-809. PubMed ID: 1891346 [TBL] [Abstract][Full Text] [Related]
30. Feasibility study for linac-based intensity modulated total marrow irradiation. Wilkie JR; Tiryaki H; Smith BD; Roeske JC; Radosevich JA; Aydogan B Med Phys; 2008 Dec; 35(12):5609-18. PubMed ID: 19175118 [TBL] [Abstract][Full Text] [Related]
31. Whole-body dose and energy measurements in radiotherapy by a combination of LiF:Mg,Cu,P and LiF:Mg,Ti. Hauri P; Schneider U Z Med Phys; 2018 Apr; 28(2):96-109. PubMed ID: 28807441 [TBL] [Abstract][Full Text] [Related]
32. Uncertainty analysis of absorbed dose calculations from thermoluminescence dosimeters. Kirby TH; Hanson WF; Johnston DA Med Phys; 1992; 19(6):1427-33. PubMed ID: 1461205 [TBL] [Abstract][Full Text] [Related]
33. Multileaf field-in-field forward-planned intensity-modulated dose compensation for whole-breast irradiation is associated with reduced contralateral breast dose: a phantom model comparison. Borghero YO; Salehpour M; McNeese MD; Stovall M; Smith SA; Johnson J; Perkins GH; Strom EA; Oh JL; Kirsner SM; Woodward WA; Yu TK; Buchholz TA Radiother Oncol; 2007 Mar; 82(3):324-8. PubMed ID: 17157944 [TBL] [Abstract][Full Text] [Related]
34. A study of the mantle technique for Hodgkins disease using thermoluminescent dosimetry. Cilliers GD; Cilliers C; Browde S Radiother Oncol; 1987 Dec; 10(4):321-6. PubMed ID: 3444908 [TBL] [Abstract][Full Text] [Related]
35. A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity. Yao R; Bernard D; Turian J; Abrams RA; Sensakovic W; Fung HC; Chu JC Med Phys; 2012 Apr; 39(4):2239-48. PubMed ID: 22482645 [TBL] [Abstract][Full Text] [Related]
37. Total skin electron irradiation: evaluation of dose uniformity throughout the skin surface. Anacak Y; Arican Z; Bar-Deroma R; Tamir A; Kuten A Med Dosim; 2003; 28(1):31-4. PubMed ID: 12747616 [TBL] [Abstract][Full Text] [Related]
38. SU-E-T-239: In Vivo Dosimetry with Surface Diodes during Total Body Irradiation: A Patient Thickness Factor to Correct Midline Dose. Nyflot M; Holdsworth C; Kalet A; Chvetsov A; Sandison G Med Phys; 2012 Jun; 39(6Part13):3758. PubMed ID: 28517306 [TBL] [Abstract][Full Text] [Related]
39. Out-of-field in vivo dosimetry using TLD in SABR for primary kidney cancer involving mixed photon fields. Lonski P; Keehan S; Siva S; Pham D; Franich RD; Taylor ML; Kron T Phys Med; 2017 May; 37():9-15. PubMed ID: 28535921 [TBL] [Abstract][Full Text] [Related]
40. Clinical thermoluminescence dosimetry: how do expectations and results compare? Kron T; Schneider M; Murray A; Mameghan H Radiother Oncol; 1993 Feb; 26(2):151-61. PubMed ID: 8465016 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]